Research on the application of inertially stabilized platform in the dynamic measurement of cold atomic gravimeter

被引:1
|
作者
Chen, Pei-jun [1 ,2 ]
Jiang, Min-rui [1 ]
Lv, Xiao-feng [1 ]
Zhou, Hang [1 ]
Yang, Di [1 ]
Zhou, Ying [1 ]
Jin, Zifan [1 ]
Peng, Shu-ping [1 ]
机构
[1] Zhejiang Univ Technol, Coll Sci, Zhejiang Prov Key Lab Quantum Precis Measurement, Hangzhou 310023, Peoples R China
[2] Huangshan Coll, Sch Mech & Elect Engn, Huangshan 245041, Peoples R China
基金
中国国家自然科学基金;
关键词
Inertially stabilized platform; High precision horizontal attitude; Cold atomic gravimeter; Absolute gravity measurement; INTERFEROMETER; CONSTANT;
D O I
10.1016/j.heliyon.2023.e23936
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Dynamic gravity field measurement based on the cold atom absolute gravity measurement system has important applications in geological exploration, gravity field mapping and other fields. The inertial stabilized platform is the key component of the dynamic cold atom absolute gravity measurement system, which can isolate the interference of carrier angle motion and keep the atomic gravimeter probe in the horizontal attitude during the measurement process. In this paper, according to the dynamic measurement requirements of atomic gravimeter, a high-precision two-axis inertial stabilized platform system is designed. The relationship between attitude angle and gravity measurement error is analyzed, and the stability of the system is enhanced by lead-lag method. Then the static vertical vibration power spectrum of the platform is measured to consider its influence on dynamic gravity measurement. Finally, a dynamic gravity test experiment was conducted in the Yellow Sea to verify the attitude control accuracy of the platform, and the attitude data of the platform under different heading were evaluated. The attitude standard deviation of the platform was better than 4 x 10-5 rad, and the absolute gravity standard deviation of the linear round-trip measurement reached 1.49 mGal. The experimental data show that the inertial stabilized platform can meet the dynamic measurement requirements of the cold atom gravimeter.
引用
收藏
页数:12
相关论文
共 44 条
  • [41] Research and Engineering Application of Xenon Dynamic-Flux Measurement Method for M310 Unit Based on Bamboo-C Code
    Fang H.
    Wei L.
    Wan C.
    Gao Y.
    Li Z.
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (01): : 11 - 18
  • [42] Research on the application of a dynamic programming method based on geodesic distance for path planning in Robot-Assisted laser scanning measurement of Free-Form surfaces
    Chen, Chen
    Jia, Huakun
    Lu, Yang
    Wu, Anan
    Zhang, Xiaodong
    Lin, Bo
    Jiyan, Zhang
    Wang, Xiangyang
    Yu, Liandong
    MEASUREMENT, 2024, 238
  • [43] Inter-software and inter-scan variability in measurement of epicardial adipose tissue: a three-way comparison of a research-specific, a freeware and a coronary application software platform
    Chan, Jasmine
    Thakur, Udit
    Tan, Sean
    Muthalaly, Rahul G.
    Thakkar, Harsh
    Goel, Vinay
    Cheen, Yeong-Chee
    Dey, Damini
    Brown, Adam J.
    Wong, Dennis T. L.
    Nerlekar, Nitesh
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 8445 - 8453
  • [44] Inter-software and inter-scan variability in measurement of epicardial adipose tissue: a three-way comparison of a research-specific, a freeware and a coronary application software platform
    Jasmine Chan
    Udit Thakur
    Sean Tan
    Rahul G. Muthalaly
    Harsh Thakkar
    Vinay Goel
    Yeong-Chee Cheen
    Damini Dey
    Adam J. Brown
    Dennis T. L. Wong
    Nitesh Nerlekar
    European Radiology, 2023, 33 : 8445 - 8453