Research on the application of inertially stabilized platform in the dynamic measurement of cold atomic gravimeter

被引:1
|
作者
Chen, Pei-jun [1 ,2 ]
Jiang, Min-rui [1 ]
Lv, Xiao-feng [1 ]
Zhou, Hang [1 ]
Yang, Di [1 ]
Zhou, Ying [1 ]
Jin, Zifan [1 ]
Peng, Shu-ping [1 ]
机构
[1] Zhejiang Univ Technol, Coll Sci, Zhejiang Prov Key Lab Quantum Precis Measurement, Hangzhou 310023, Peoples R China
[2] Huangshan Coll, Sch Mech & Elect Engn, Huangshan 245041, Peoples R China
基金
中国国家自然科学基金;
关键词
Inertially stabilized platform; High precision horizontal attitude; Cold atomic gravimeter; Absolute gravity measurement; INTERFEROMETER; CONSTANT;
D O I
10.1016/j.heliyon.2023.e23936
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Dynamic gravity field measurement based on the cold atom absolute gravity measurement system has important applications in geological exploration, gravity field mapping and other fields. The inertial stabilized platform is the key component of the dynamic cold atom absolute gravity measurement system, which can isolate the interference of carrier angle motion and keep the atomic gravimeter probe in the horizontal attitude during the measurement process. In this paper, according to the dynamic measurement requirements of atomic gravimeter, a high-precision two-axis inertial stabilized platform system is designed. The relationship between attitude angle and gravity measurement error is analyzed, and the stability of the system is enhanced by lead-lag method. Then the static vertical vibration power spectrum of the platform is measured to consider its influence on dynamic gravity measurement. Finally, a dynamic gravity test experiment was conducted in the Yellow Sea to verify the attitude control accuracy of the platform, and the attitude data of the platform under different heading were evaluated. The attitude standard deviation of the platform was better than 4 x 10-5 rad, and the absolute gravity standard deviation of the linear round-trip measurement reached 1.49 mGal. The experimental data show that the inertial stabilized platform can meet the dynamic measurement requirements of the cold atom gravimeter.
引用
收藏
页数:12
相关论文
共 44 条
  • [31] Application of torsional vibration measurement technique on dynamic strength test and research of friction discs
    Zhou, GM
    Zhang, HY
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 799 - 802
  • [32] Formulation of indicators for the measurement of products of engineering research groups for their application in the SINFONI platform of the Cooperative University of Colombia
    Robayo-Botiva, Diana M.
    Sierra-Alvarez, William
    Colmenares, Ramon F.
    INGENIERIA Y COMPETITIVIDAD, 2021, 23 (02):
  • [33] Research on Field Application Technology of Dynamic Angle Measurement Based on Fiber Optic Gyroscope and Autocollimator
    Mou, Jiapeng
    Su, Jingjing
    Miao, Lijun
    Huang, Tengchao
    IEEE SENSORS JOURNAL, 2021, 21 (13) : 15308 - 15317
  • [34] Research on error dynamic amendment method and its application in high-accuracy thickness measurement system
    Qian, Suxiang
    Shen, Xiaomei
    Cao, Jian
    Zhou, Zhenfeng
    Gu, Xiaojun
    WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 4940 - +
  • [35] Application research for gas turbine dynamic gap detection based on fiber-optic measurement technology
    Ma, HP
    Liu, LH
    Yang, LM
    Wang, ZY
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS, 2002, 4920 : 422 - 426
  • [36] Research on the application of Edlen's formulation in compensation for ultra-precision motion platform's measurement using an interferometer
    Gao, Zhenyu
    Hu, Jinchun
    Zhu, Yu
    Duan, Guanghong
    Zhang, Ming
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2012, 34 (05) : 635 - 647
  • [37] Application of a dynamic atomic force microscope for the measurement of lubrication forces and hydrodynamic thickness between surfaces bearing adsorbed polyelectrolyte layers
    Notley, SM
    Biggs, S
    Craig, VSJ
    MACROMOLECULES, 2003, 36 (08) : 2903 - 2906
  • [38] Research on frequency-shifting iterative filtering method for dynamic frequency measurement of power system and its application
    Luo D.
    Wen H.
    Tang L.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (05): : 151 - 156
  • [39] Research on Dynamic Equivalent for Hydropower Generator Group Based on Phasor Measurement Information Part II: Application in Real Power System
    Shi, Huabo
    Ding, Lijie
    Zhang, Hua
    Chen, Gang
    PROCEEDINGS OF THE 2016 6TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS, ENVIRONMENT, BIOTECHNOLOGY AND COMPUTER (MMEBC), 2016, 88 : 2192 - 2197
  • [40] DYNAMIC ASPECT OF COLLISIONS IN ATOMIC LINE-PROFILE COMPUTATION - APPLICATION TO THE RESEARCH OF HG(6P1-3)-HEAVY NOBLE-GAS INTER-ATOMIC POTENTIALS
    LEBOUCHER, E
    JOURNAL DE PHYSIQUE, 1981, 42 (06): : 813 - 826