Single-sided magnetic resonance-based sensor for point-of-care evaluation of muscle

被引:2
|
作者
Sherman, Sydney E. [1 ,2 ]
Zammit, Alexa S. [2 ,3 ]
Heo, Won-Seok [2 ]
Rosen, Matthew S. [4 ,5 ,6 ]
Cima, Michael J. [2 ,3 ]
机构
[1] MIT, Harvard MIT Program Hlth Sci & Technol, Cambridge, MA 02139 USA
[2] MIT, Koch Inst Integrat Canc Res, Cambridge, MA 02139 USA
[3] MIT, Dept Mat Sci & Engn, Cambridge, MA 02139 USA
[4] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Boston, MA 02129 USA
[5] Harvard Med Sch, Boston, MA 02115 USA
[6] Harvard Univ, Dept Phys, Cambridge, MA 02138 USA
基金
美国国家卫生研究院;
关键词
UNILATERAL NMR;
D O I
10.1038/s41467-023-44561-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Magnetic resonance imaging is a widespread clinical tool for the detection of soft tissue morphology and pathology. However, the clinical deployment of magnetic resonance imaging scanners is ultimately limited by size, cost, and space constraints. Here, we discuss the design and performance of a low-field single-sided magnetic resonance sensor intended for point-of-care evaluation of skeletal muscle in vivo. The 11 kg sensor has a penetration depth of >8 mm, which allows for an accurate analysis of muscle tissue and can avoid signal from more proximal layers, including subcutaneous adipose tissue. Low operational power and shielding requirements are achieved through the design of a permanent magnet array and surface transceiver coil. The sensor can acquire high signal-to-noise measurements in minutes, making it practical as a point-of-care tool for many quantitative diagnostic measurements, including T2 relaxometry. In this work, we present the in vitro and human in vivo performance of the device for muscle tissue evaluation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Assessing the Performance of Hydrophobing Agents on Concrete Using Nondestructive Single-Sided Nuclear Magnetic Resonance
    Weichold, Oliver
    Antons, Udo
    JOURNAL OF INFRASTRUCTURE SYSTEMS, 2017, 23 (04) : 1 - 6
  • [22] Development of a Single-Sided Nuclear Magnetic Resonance Scanner for the In Vivo Quantification of Live Cattle Marbling
    Nakashima, Yoshito
    APPLIED MAGNETIC RESONANCE, 2015, 46 (05) : 593 - 606
  • [23] Cardiovascular magnetic resonance-based evaluation of myocardial rotational mechanics
    Kowallick, Johannes Tammo
    Schuster, Andreas
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2014, 307 (11): : H1685 - H1685
  • [24] Design and experimental validation of Unilateral Linear Halbach magnet arrays for single-sided magnetic resonance
    Bashyam, Ashvin
    Li, Matthew
    Cima, Michael J.
    JOURNAL OF MAGNETIC RESONANCE, 2018, 292 : 36 - 43
  • [25] Development of a Single-Sided Nuclear Magnetic Resonance Scanner for the In Vivo Quantification of Live Cattle Marbling
    Yoshito Nakashima
    Applied Magnetic Resonance, 2015, 46 : 593 - 606
  • [26] Dehydration assessment via portable, single sided magnetic resonance sensor
    Bashyam, Ashvin
    Frangieh, Chris J.
    Li, Matthew
    Cima, Michael J.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (04) : 1390 - 1404
  • [27] Tuning the Electric Resonance of a Metamaterial Based Single-Sided S-Shaped Resonator
    Nesimoglu, Tayfun
    Karaali, Melih
    Sabah, Cumali
    2014 20TH INTERNATIONAL CONFERENCE ON MICROWAVES, RADAR, AND WIRELESS COMMUNICATION (MIKON), 2014,
  • [28] Self-diffusion measurements by a mobile single-sided NMR sensor with improved magnetic field gradient
    Rata, D. G.
    Casanova, F.
    Perlo, J.
    Demco, D. E.
    Bluemich, B.
    JOURNAL OF MAGNETIC RESONANCE, 2006, 180 (02) : 229 - 235
  • [29] Ferritin Determination in Blood Using a Point-of-Care Surface Plasmon Resonance Sensor
    Dubois, C.
    Robidoux, J.
    Masson, J.
    Brouard, D.
    TRANSFUSION, 2023, 63
  • [30] Influence of fresh concrete pressure on cover porosity investinated by single-sided proton nuclear magnetic resonance
    Holthausen, Robert Schulte
    Raupach, Michael
    MAGAZINE OF CONCRETE RESEARCH, 2021, 73 (01) : 45 - 54