Self-diffusion measurements by a mobile single-sided NMR sensor with improved magnetic field gradient

被引:78
|
作者
Rata, D. G. [1 ]
Casanova, F. [1 ]
Perlo, J. [1 ]
Demco, D. E. [1 ]
Bluemich, B. [1 ]
机构
[1] Rhein Westfal TH Aachen, Inst Tech Chem & Makromol Chem, D-52056 Aachen, Germany
关键词
NMR; self-diffusion; static gradient; unilateral NMR; cross-linked elastomers; porous media; Achilles tendon; restricted diffusion;
D O I
10.1016/j.jmr.2006.02.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and fast method of measuring self-diffusion coefficients of protonated systems with a mobile single-sided NMR sensor is discussed. The NMR sensor uses a magnet geometry that generates a highly flat sensitive volume where a strong and highly uniform static magnetic field gradient is defined. Self-diffusion coefficients were measured by Hahn- and stimulated echoes detected in the presence of the uniform magnetic field gradient of the static field. To improve the sensitivity of these experiments, a Carr-Purcell-Meiboom-Gill pulse sequence was applied after the main diffusion-encoding period. By adding the echo train the experimental time was strongly shortened, allowing the measurement of complete diffusion curves in less than 1 min. This method has been tested by measuring the self-diffusion coefficients D of various organic solvents and poly(dimethylsiloxane) samples with different molar masses. Diffusion coefficients were also measured for n-hexane absorbed at saturation in natural rubber with different cross-link densities. The results show a dependence on the concentration that is in good agreement with the theoretical prediction. Moreover, the stimulated-echo sequence was successfully used to measure the diffusion coefficient as a function of the evolution time in systems with restricted diffusion. This type of experiment proves the pore geometry and gives access to the surface-to-volume ratio. It was applied to measure the diffusion of water in sandstones and sheep Achilles tendon. Thanks to the strong static gradient Go, all diffusion coefficients could be measured without having to account for relaxation during the pulse sequence. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:229 / 235
页数:7
相关论文
共 50 条
  • [1] Self-diffusion coefficient by single-sided NMR
    Casieri, C
    Bubici, S
    De Luca, F
    JOURNAL OF MAGNETIC RESONANCE, 2003, 162 (02) : 348 - 355
  • [2] AN ALTERNATING PULSED MAGNETIC-FIELD GRADIENT APPARATUS FOR NMR SELF-DIFFUSION MEASUREMENTS
    HROVAT, MI
    BRITT, CO
    MOORE, TC
    WADE, CG
    JOURNAL OF MAGNETIC RESONANCE, 1982, 49 (03) : 411 - 424
  • [4] Mobile single-sided NMR
    Bluemich, B.
    Perlo, J.
    Casanova, F.
    PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2008, 52 (04) : 197 - 269
  • [5] Single-Sided Magnetic Particle Imaging: Magnetic Field and Gradient
    Graefe, K.
    Gruettner, M.
    Sattel, T. F.
    Graeser, M.
    Buzug, T. M.
    MEDICAL IMAGING 2013: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2013, 8672
  • [6] Estimation of Self-Diffusion Coefficients of Small Penetrants in Semicrystalline Polymers Using Single-Sided NMR
    Kwamen, R.
    Bluemich, B.
    Adams, A.
    MACROMOLECULAR RAPID COMMUNICATIONS, 2012, 33 (10) : 943 - 947
  • [7] VIOLATION OF THE GRADIENT APPROXIMATION IN NMR SELF-DIFFUSION MEASUREMENTS
    STEPISNIK, J
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 1995, 190 : 51 - 62
  • [8] A COMPUTER-CONTROLLED BIPOLAR MAGNETIC-FIELD-GRADIENT DRIVER FOR NMR ELECTROPHORETIC AND SELF-DIFFUSION MEASUREMENTS
    BOERNER, RM
    WOODWARD, WS
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1994, 106 (02) : 195 - 202
  • [9] Single-sided mobile NMR with a Halbach magnet
    Chang, Wei-Hao
    Chen, Jyh-Horng
    Hwang, Lian-Pin
    MAGNETIC RESONANCE IMAGING, 2006, 24 (08) : 1095 - 1102
  • [10] Pulsed field gradient magic angle spinning NMR self-diffusion measurements in liquids
    Viel, Stephane
    Ziarelli, Fabio
    Pages, Guilhem
    Carrara, Caroline
    Caldarelli, Stefano
    JOURNAL OF MAGNETIC RESONANCE, 2008, 190 (01) : 113 - 123