Delivery of proton FLASH at the TRIUMF Proton Therapy Research Centre

被引:3
|
作者
Belanger-Champagne, Camille [1 ]
Roddy, David [1 ,2 ]
Penner, Crystal [1 ]
Tattenberg, Sebastian [1 ,3 ]
Trinczek, Michael [1 ]
Yen, Stan [1 ]
Blackmore, Ewart [1 ]
Hoehr, Cornelia [1 ]
机构
[1] TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[2] Univ Edinburgh, Edinburgh EH9 3FD, Scotland
[3] NOSM Univ, Sudbury, ON P3E 2C6, Canada
关键词
FLASH radiotherapy; Proton therapy; Beam delivery; Ridge filter; Proton energy modulation; DESIGN;
D O I
10.1016/j.nima.2023.168243
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The TRIUMF particle accelerator center in Vancouver, British Columbia, Canada houses a proton therapy beam line formerly used for the treatment of ocular cancer. This existing Proton Therapy Research Centre (PTRC) was upgraded to deliver protons at ultra-high dose rates which would be required for FLASH radiotherapy treatments. A peak dose rate of 110 Gy/s over an area of 20 mm2 was delivered at a beam energy of 21 MeV. This was achieved by degrading the cyclotron extracted beam energy of 70 MeV using polymethyl methacrylate (PMMA) plates. In addition, a fast, versatile and reliable method for producing static ridge filters has been developed to spread the proton beam to the entirety of the target axially (i.e., in depth). FLASH dose rates were maintained with a spread-out Bragg peak of 0.5 cm.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [31] FLASH instead of proton arc therapy is a more promising advancement for the next generation proton radiotherapy
    Kang, Minglei
    Ding, Xuanfeng
    Rong, Yi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (08):
  • [32] A Parametric Approach Towards New Proton Facility Shielding Considerations in the Era of Proton FLASH Therapy
    Gupta, N.
    DiCostanzo, D.
    Ayan, A.
    Woollard, J.
    Meissner, J.
    Hintenlang, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E687 - E687
  • [33] Proton-FLASH
    Poulsen, P.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S844 - S845
  • [34] Quality Assurances for Proton Therapy Delivery Equipment
    Arjomandy, B.
    Klein, E.
    Taylor, P.
    Ainsley, C.
    Safai, S.
    Sahoo, N.
    Pankuch, M.
    Park, S.
    Farr, J.
    Kase, Y.
    Flanz, J.
    Yorke, E.
    Followill, D.
    MEDICAL PHYSICS, 2015, 42 (06) : 3485 - 3486
  • [35] IMPROVING THE DELIVERY AND SAFETY OF PROTON BEAM THERAPY
    Buchsbaum, J.
    Jyoti, B.
    Simoneaux, V.
    Reed, R.
    Conley, T.
    PEDIATRIC BLOOD & CANCER, 2014, 61 : S222 - S222
  • [36] Improving the Delivery and Safety of Proton Beam Therapy
    Buchsbaum, J.
    Reed, R.
    Conley, T.
    Babita, J.
    Simoneaux, V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S786 - S786
  • [37] Toward robust proton therapy planning and delivery
    Li, Zuofeng
    TRANSLATIONAL CANCER RESEARCH, 2012, 1 (03) : 217 - 226
  • [38] Pencil-beam Delivery Pattern Optimization Increases Dose Rate for Stereotactic FLASH Proton Therapy
    Santo, Rodrigo Jose
    Habraken, Steven J. M.
    Breedveld, Sebastiaan
    Hoogeman, Mischa S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 115 (03): : 759 - 767
  • [39] The control system for a new proton extraction probe at TRIUMF
    Morris, DB
    Lee, KS
    ACCELERATOR AND LARGE EXPERIMENTAL PHYSICS CONTROL SYSTEMS, 1997, : 253 - 255
  • [40] VARIABLE ENERGY POLARIZED PROTON-BEAM AT TRIUMF
    BEVERIDGE, JL
    CRADDOCK, MK
    DUTTO, G
    ORAM, C
    ROOT, LW
    ROY, G
    SCHMOR, PW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (02): : 168 - 168