Purpose: FLASH dose rates >40 Gy/s are readily available in proton therapy (PT) with cyclotron-accelerated beams and pencil-beam scanning (PBS). The PBS delivery pattern will affect the local dose rate, as quantified by the PBS dose rate (PBS-DR), and therefore needs to be accounted for in FLASH-PT with PBS, but it is not yet clear how. Our aim was to optimize patient-specific scan patterns for stereotactic FLASH-PT of early-stage lung cancer and lung metastases, maximizing the volume irradiated with PBS-DR >40 Gy/s of the organs at risk voxels irradiated to >8 Gy (FLASH coverage). Methods and Materials: Plans to 54 Gy/3 fractions with 3 equiangular coplanar 244 MeV proton shoot-through transmission beams for 20 patients were optimized with in-house developed software. Planning target volume-based planning with a 5 mm margin was used. Planning target volume ranged from 4.4 to 84 cc. Scan-pattern optimization was performed with a Genetic Algorithm, run in parallel for 20 independent populations (islands). Mapped crossover, inversion, swap, and shift operators were applied to achieve (local) optimality on each island, with migration between them for global optimality. The cost function was chosen to maximize the FLASH coverage per beam at >8 Gy, >40 Gy/s, and 40 nA beam current. The optimized patterns were evaluated on FLASH coverage, PBS-DR distribution, and population PBS-DR-volume histograms, compared with standard line-by-line scanning. Robustness against beam current variation was investigated. Results: The optimized patterns have a snowflake-like structure, combined with outward swirling for larger targets. A population median FLASH coverage of 29.0% was obtained for optimized patterns compared with 6.9% for standard patterns, illustrating a significant increase in FLASH coverage for optimized patterns. For beam current variations of 5 nA, FLASH coverage varied between -6.1%-point and 2.2%-point for optimized patterns. Conclusions: Significant improvements on the PBS-DR and, hence, on FLASH coverage and potential healthy-tissue sparing are obtained by sequential scan-pattern optimization. The optimizer is flexible and may be further fine-tuned, based on the exact conditions for FLASH. (c) 2022 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
引用
收藏
页码:759 / 767
页数:9
相关论文
共 50 条
  • [1] Definition of dose rate for FLASH pencil-beam scanning proton therapy: A comparative study
    Deffet, Sylvain
    Hamaide, Valentin
    Sterpin, Edmond
    [J]. MEDICAL PHYSICS, 2023, 50 (09) : 5784 - 5792
  • [2] Simultaneous dose and dose rate optimization (SDDRO) of the FLASH effect for pencil-beam-scanning proton therapy
    Gao, Hao
    Liu, Jiulong
    Lin, Yuting
    Gan, Gregory N
    Pratx, Guillem
    Wang, Fen
    Langen, Katja
    Bradley, Jeffrey D
    Rotondo, Ronny L
    Li, Harold H
    Chen, Ronald C
    [J]. Medical Physics, 2022, 49 (03): : 2014 - 2025
  • [3] Simultaneous dose and dose rate optimization (SDDRO) of the FLASH effect for pencil-beam-scanning proton therapy
    Gao, Hao
    Liu, Jiulong
    Lin, Yuting
    Gan, Gregory N.
    Pratx, Guillem
    Wang, Fen
    Langen, Katja
    Bradley, Jeffrey D.
    Rotondo, Ronny L.
    Li, Harold H.
    Chen, Ronald C.
    [J]. MEDICAL PHYSICS, 2022, 49 (03) : 2014 - 2025
  • [4] Implementation of apertures in a proton pencil-beam dose algorithm
    Depauw, N.
    Kooy, H. M.
    Daartz, J.
    Bussiere, M.
    Batin, E.
    Madden, T.
    Williams, M.
    Schueman, J.
    Clasie, B. M.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02)
  • [5] A CASE STUDY IN PROTON PENCIL-BEAM SCANNING DELIVERY
    Kooy, Hanne M.
    Clasie, Benjamin M.
    Lu, Hsiao-Ming
    Madden, Thomas M.
    Bentefour, Hassan
    Depauw, Nicolas
    Adams, Judy A.
    Trofimov, Alexei V.
    Demaret, Denis
    Delaney, Thomas F.
    Flanz, Jacob B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (02): : 624 - 630
  • [6] Robust optimization for IMPT of pencil-beam scanning proton therapy for prostate cancer
    Brouwer, C. L.
    Matysiak, W. P.
    Klinker, P.
    Spijkerman-Bergsma, M.
    Hammer, C.
    Van den Bergh, A. C. M.
    Langendijk, J. A.
    Scandurra, D.
    Korevaar, E. W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S835 - S836
  • [7] Time-resolved dose rate measurements in pencil beam scanning proton FLASH therapy
    Kanouta, E.
    Poulsen, P.
    Kertzscher, G.
    Sitarz, M.
    Sorensen, B.
    Johansen, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S240 - S242
  • [8] FLASH dose rate calculation based on log files in proton pencil beam scanning therapy
    Jeon, Chanil
    Ahn, Sunghwan
    Amano, Daizo
    Kamiguchi, Nagaaki
    Cho, Sungkoo
    Sheen, Heesoon
    Park, Hee Chul
    Han, Youngyih
    [J]. MEDICAL PHYSICS, 2023, 50 (11) : 7154 - 7166
  • [9] Incorporation of the aperture thickness in proton pencil-beam dose calculations
    Slopsema, Roelf L.
    Kooy, Hanne M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21): : 5441 - 5453
  • [10] SDDRO-PBS: Simultaneous Dose and Dose Rate Optimization for FLASH Proton SBRT Based on Pencil Beam Scanning Dose Rate Modeling
    Gao, H.
    Folkerts, M. M.
    Lin, Y.
    Abel, E.
    Bradley, J. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E553 - E553