Dosimetry of [18F]TRACK, the first PET tracer for imaging of TrkB/C receptors in humans

被引:1
|
作者
Thiel, Alexander [1 ,2 ,3 ]
Kostikov, Alexey [3 ,4 ,5 ]
Ahn, Hailey [1 ,2 ,6 ]
Daoud, Youstina [1 ,2 ,6 ]
Soucy, Jean-Paul [3 ,4 ,7 ]
Blinder, Stephan [4 ,7 ]
Jaworski, Carolin [8 ]
Waengler, Carmen [9 ]
Waengler, Bjoern [10 ]
Juengling, Freimut [11 ,12 ,13 ]
Enger, Shirin A. [1 ,2 ,6 ]
Schirrmacher, Ralf [8 ,12 ]
机构
[1] Jewish Gen Hosp, 3755 Chemin Cote St Catherine, Montreal, PQ H3T 1E2, Canada
[2] Lady Davis Inst Med Res, 3755 Chemin Cote St Catherine, Montreal, PQ H3T 1E2, Canada
[3] McGill Univ, Dept Neurol & Neurosurg, Montreal, PQ, Canada
[4] Montreal Neurol Inst, Brain Imaging Ctr, Montreal, PQ, Canada
[5] McGill Univ, Dept Chem, Montreal, PQ, Canada
[6] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[7] Concordia Univ, PERFORM Ctr, Montreal, PQ, Canada
[8] Univ Alberta, Cross Canc Inst, Med Isotope & Cyclotron Facil, Edmonton, AB, Canada
[9] Heidelberg Univ, Med Fac Mannheim, Clin Radiol & Nucl Med, Biomed Chem, Mannheim, Germany
[10] Heidelberg Univ, Med Fac Mannheim, Clin Radiol & Nucl Med, Mol Imaging & Radiochem, Mannheim, Germany
[11] Univ Alberta, Neurosci & Mental Hlth Inst, Edmonton, AB, Canada
[12] Univ Alberta, Dept Oncol, Div Oncol Imaging, Edmonton, AB, Canada
[13] Univ Bern, Med Fac, Bern, Switzerland
基金
加拿大健康研究院;
关键词
Tropomyosin receptor kinases; Positron emission tomography; F-18]TRACK; Dosimetry;
D O I
10.1186/s41181-023-00219-x
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Background: Reduced expression or impaired signalling of tropomyosin receptor kinases (Trk receptors) are found in a vast spectrum of CNS disorders. [F-18]TRACK is the first PET radioligand for TrkB/C with proven in vivo brain penetration and on-target specific signal. Here we report dosimetry data for [F-18]TRACK in healthy humans. 6 healthy participants (age 22-61 y, 3 female) were scanned on a General Electric Discovery PET/CT 690 scanner. [F-18]TRACK was synthesized with high molar activities (A(m) = 250 +/- 75 GBq/mu mol), and a dynamic series of 12 whole-body scans were acquired after injection of 129 to 147 MBq of the tracer. Images were reconstructed with standard corrections using the manufacturer's OSEM algorithm. Tracer concentration time-activity curves (TACs) were obtained using CT-derived volumes-of-interest. Organ-specific doses and the total effective dose were estimated using the Committee on Medical Internal Radiation Dose equation for adults and tabulated Source tissue values (S values).Results: Average organ absorbed dose was highest for liver and gall bladder with 6.1E-2 (+/- 1.06E-2) mGy/MBq and 4.6 (+/- 1.18E-2) mGy/MBq, respectively. Total detriment weighted effective dose E-DW was 1.63E-2 +/- 1.68E-3 mSv/MBq. Organ-specific TACs indicated predominantly hepatic tracer elimination.Conclusion: Total and organ-specific effective doses for [F-18]TRACK are low and the dosimetry profile is similar to other F-18-labelled radio tracers currently used in clinical settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Bridging the gaps in 18F PET tracer development
    Campbell, Michael G.
    Mercier, Joel
    Genicot, Christophe
    Gouverneur, Veronique
    Hooker, Jacob M.
    Ritter, Tobias
    NATURE CHEMISTRY, 2017, 9 (01) : 1 - 3
  • [42] Efficient radiosynthesis and preclinical evaluation of [18F]FOMPyD as a positron emission tomography tracer candidate for TrkB/C receptor imaging
    Singleton, Thomas A.
    Bdair, Hussein
    Bailey, Justin J.
    Choi, Sangho
    Aliaga, Arturo
    Rosa-Neto, Pedro
    Schirrmacher, Ralf
    Bernard-Gauthier, Vadim
    Kostikov, Alexey
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2020, 63 (03): : 144 - 150
  • [43] Evaluation of [18F]FPyKYNE-losartan as a novel PET tracer for imaging kidney AT1 receptors in rats
    Ismail, Basma
    Arksey, Natasha
    Hadizad, Tayebeh
    Croteau, Etienne
    Thibodeau, Jean-Francois
    Kennedy, Christopher
    Hebert, Richard
    deKemp, Robert
    Beanlands, Rob
    DaSilva, Jean
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [44] Radiolabeling of [18F]-fluoroethylnormemantine and initial in vivo evaluation of this innovative PET tracer for imaging the PCP sites of NMDA receptors
    Salabert, Anne-Sophie
    Fonta, Caroline
    Fontan, Charlotte
    Adel, Djilali
    Alonso, Mathieu
    Pestourie, Carine
    Belhadj-Tahar, Hafid
    Tafani, Mathieu
    Payoux, Pierre
    NUCLEAR MEDICINE AND BIOLOGY, 2015, 42 (08) : 643 - 653
  • [45] High Correlation of Static First-Minute-Frame (FMF) PET Imaging after 18F-Labeled Amyloid Tracer Injection with [18F]FDG PET Imaging
    Seiffert, Alexander P.
    Gomez-Grande, Adolfo
    Villarejo-Galende, Alberto
    Gonzalez-Sanchez, Marta
    Bueno, Hector
    Gomez, Enrique J.
    Sanchez-Gonzalez, Patricia
    SENSORS, 2021, 21 (15)
  • [46] PET Imaging of Somatostatin Receptors with Fluorine-18: Microfluidic Radiosynthesis and Preclinical Dosimetry of [18F]AMBF3-TATE
    Lisova, Ksenia
    Sergeev, Maxim
    Axelsson, Susan Evans
    Stuparu, Andreea
    Beykan, Seval
    Herrmann, Ken
    Czernin, Johannes
    Lassmann, Michael
    Lee, Jason T.
    Perrin, David
    Slavik, Roger J.
    van Dam, R. Michael
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2017, 60 : S524 - S524
  • [47] Human biodistribution and dosimetry of [18F]nifene, an α4β2*nicotinic acetylcholine receptor PET tracer
    Betthauser, Tobey J.
    Hillmer, Ansel T.
    Lao, Patrick J.
    Ehlerding, Emily
    Mukherjee, Jogeshwar
    Stone, Charles K.
    Christian, Bradley T.
    NUCLEAR MEDICINE AND BIOLOGY, 2017, 55 : 7 - 11
  • [48] Correction: Radiation dosimetry and pharmacokinetics of the tau PET tracer florzolotau (18F) in healthy Japanese subjects
    Masaomi Miyamoto
    Chio Okuyama
    Shinya Kagawa
    Kuninori Kusano
    Masaaki Takahashi
    Keisuke Takahata
    Ming-Kuei Jang
    Hiroshi Yamauchi
    Annals of Nuclear Medicine, 2024, 38 : 328 - 328
  • [49] A novel synthesis of 6"-[18F]-fluoromaltotriose as a PET tracer for imaging bacterial infection
    Namavari, Mohammad
    Gowrishankar, Gayatri
    Srinivasan, Ananth
    Gambhir, Sanjiv S.
    Haywood, Thomas
    Beinat, Corinne
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2018, 61 (05): : 408 - 414
  • [50] Preparation of the hypoxia imaging PET tracer [18F]FAZA:: reaction parameters and automation
    Reischl, G
    Ehrlichmann, W
    Bieg, C
    Solbach, C
    Kumar, P
    Wiebe, LI
    Machulla, H
    APPLIED RADIATION AND ISOTOPES, 2005, 62 (06) : 897 - 901