Rapid Whole-Body FDG PET/MRI in Oncology Patients: Utility of Combining Bayesian Penalised Likelihood PET Reconstruction and Abbreviated MRI

被引:2
|
作者
Inukai, Junko Inoue [1 ]
Nogami, Munenobu [2 ,3 ]
Tachibana, Miho [1 ]
Zeng, Feibi [2 ]
Nishitani, Tatsuya [2 ]
Kubo, Kazuhiro [2 ]
Murakami, Takamichi [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Radiol, 7-5-1 Kusunoki Cho, Chuo Ku, Kobe, Hyogo 6500017, Japan
[2] Kobe Univ Hosp, Dept Radiol, 7-5-2 Kusunoki Cho, Chuo Ku, Kobe, Hyogo 6500017, Japan
[3] Univ Fukui, Biomed Imaging Res Ctr, Div Med Imaging, 23-3 Matsuokashimoaizuki, Yoshida, Fukui 9101193, Japan
基金
日本学术振兴会;
关键词
PET; MRI; image reconstruction; fluorodeoxyglucose; Bayesian penalised likelihood; whole-body imaging; abbreviated MRI; Q.CLEAR;
D O I
10.3390/diagnostics13111871
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated the diagnostic value of a rapid whole-body fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance imaging (MRI) approach, combining Bayesian penalised likelihood (BPL) PET with an optimised beta value and abbreviated MRI (abb-MRI). The study compares the diagnostic performance of this approach with the standard PET/MRI that utilises ordered subsets expectation maximisation (OSEM) PET and standard MRI (std-MRI). The optimal beta value was determined by evaluating the noise-equivalent count (NEC) phantom, background variability, contrast recovery, recovery coefficient, and visual scores (VS) for OSEM and BPL with beta 100-1000 at 2.5-, 1.5-, and 1.0-min scans, respectively. Clinical evaluations were conducted for NECpatient, NECdensity, liver signal-to-noise ratio (SNR), lesion maximum standardised uptake value, lesion signal-to-background ratio, lesion SNR, and VS in 49 patients. The diagnostic performance of BPL/abb-MRI was retrospectively assessed for lesion detection and differentiation in 156 patients using VS. The optimal beta values were beta 600 for a 1.5-min scan and beta 700 for a 1.0-min scan. BPL/abb-MRI at these beta values was equivalent to OSEM/std-MRI for a 2.5-min scan. By combining BPL with optimal beta and abb-MRI, rapid whole-body PET/MRI could be achieved in <= 1.5 min per bed position, while maintaining comparable diagnostic performance to standard PET/MRI.
引用
收藏
页数:16
相关论文
共 50 条
  • [11] Whole-body tumor staging: MRI or FDG-PET/CT?
    Antoch, G
    Vogt, FM
    Bockisch, A
    Ruehm, SG
    RADIOLOGE, 2004, 44 (09): : 882 - 888
  • [12] Whole Body MRI and FDG PET in Myeloma
    Lindenberg, Liza
    Mena, Esther
    Ton, Anita
    Turkbey, Baris
    Hill, Elizabeth
    Eclarinal, Philip
    Daar, Dagane
    Tieu, Hoa
    Leyson, Christopher
    Cedo, Mona Lisa
    Weaver, Juanita
    McKinney, Yolanda
    Dew, Alexander
    Braylan, Raul
    Wang, Hao-Wei
    Yuan, Constance
    Maric, Irina
    Stetler-Stevenson, Maryalice
    Calvo, Katherine
    Dulau-Florea, Alina
    Choyke, Peter
    Kazandjian, Dickran
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [13] Combined PET/MRI: a new dimension in whole-body oncology imaging?
    Gerald Antoch
    Andreas Bockisch
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 113 - 120
  • [14] Whole-body PET/MRI in oncology: Current status and clinical applications
    Pace L.
    Nicolai E.
    Aiello M.
    Catalano O.A.
    Salvatore M.
    Clinical and Translational Imaging, 2013, 1 (1) : 31 - 44
  • [15] Combined PET/MRI: a new dimension in whole-body oncology imaging?
    Antoch, Gerald
    Bockisch, Andreas
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : 113 - 120
  • [16] Response assessment of pediatric malignancies using whole-body MRI and FDG-PET/MRI
    Theruvath, A. J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 367 - 369
  • [17] Whole-Body Functional MRI and PET/MRI in Multiple Myeloma
    Mule, Sebastien
    Reizine, Edouard
    Blanc-Durand, Paul
    Baranes, Laurence
    Zerbib, Pierre
    Burns, Robert
    Nouri, Refaat
    Itti, Emmanuel
    Luciani, Alain
    CANCERS, 2020, 12 (11) : 1 - 11
  • [18] WHOLE-BODY FDG-PET ONCOLOGY ATLAS
    BROWN, CV
    KHONSARY, SA
    BHATTATHIRY, M
    ROPCHAN, JR
    FARAHI, JB
    QUINONES, N
    RIBE, JY
    COLOURIS, GC
    GLASS, EC
    COYLE, JJ
    MANDELKERN, MA
    BLAHD, WH
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P273 - P273
  • [19] Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology
    Antoch, G
    Vogt, FM
    Freudenberg, LS
    Nazaradeh, F
    Goehde, SC
    Barkhausen, J
    Dahmen, G
    Bockisch, A
    Debatin, JF
    Ruehm, SG
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (24): : 3199 - 3206
  • [20] Whole-body PET/MRI of Pediatric Patients: The Details That Matter
    Pareek, Anuj
    Muehe, Anne M.
    Theruvath, Ashok J.
    Gulaka, Praveen K.
    Spunt, Sheri L.
    Daldrup-Link, Heike E.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (130):