Automated fetal heart rate analysis for baseline determination using EMAU-Net

被引:4
|
作者
Liu, Mujun [1 ]
Zeng, Rongdan [2 ]
Xiao, Yahui [2 ]
Lu, Yaosheng [2 ]
Wu, Yi [1 ]
Long, Shun [3 ]
Liu, Jia [4 ]
Zheng, Zheng [5 ]
Wang, Huijin [3 ]
Bai, Jieyun [2 ]
机构
[1] Army Med Univ, Third Mil Med Univ, Coll Biomed Engn & Imaging Med, Dept Digital Med, Chongqing 400038, Peoples R China
[2] Jinan Univ, Coll Informat Sci & Technol, Dept Elect Engn, Guangzhou 510632, Peoples R China
[3] Jinan Univ, Coll Informat Sci & Technol, Dept Comp Sci, Guangzhou 510632, Peoples R China
[4] Jinan Univ, Affiliated Hosp 1, Guangzhou 510630, Peoples R China
[5] Guangzhou Med Univ, Guangzhou Women & Childrens Med Ctr, Dept Obstet, Preterm Birth Prevent & Treatment Res Unit, Guangzhou 510623, Peoples R China
关键词
Acceleration; Baseline; Convolutional Neural Network; Deceleration; Fetal Heart Rate; ALGORITHM; NETWORK;
D O I
10.1016/j.ins.2023.119281
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Automatic baseline determination is crucial for reducing the occurrence of fetal acidosis in clinical practice. However, there is a nonnegligible gap between the results of automatic baseline determination and the consensus of experts. In this paper, we propose a novel deep learning approach for baseline determination. First, potential accelerations/decelerations are recognized from the fetal heart rate and excluded by an ensemble multiattention U-Net. Then, the reference baseline and reliable interval are calculated via long- and short-term filters. Based on the filters, unreliable points for estimating the baseline are removed, and the final baseline is determined. We evaluate the performance of the proposed method on a public and a private database. Compared with state-of-the-art methods, our method yields better performance (the root mean square difference between baselines (BL. RMSD), F-measures for acceleration and deceleration (Acc/Dec. F-measures), the synthetic inconsistency coefficient (SI), and the morphological analysis discordance index (MADI) are 2.84 bpm, 0.80, 0.77, 48.9% and 3.94%, respectively) on the public database. The proposed method performs optimally in all metrics on the private database (BL. RMSD, Acc/Dec. F-measures, SI, and MADI are 1.75 bpm, 0.88, 0.80, 43.5%, and 3.11%, respectively). The experimental results indicate the effectiveness and generalizability of the proposed method.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] BASELINE FETAL HEART-RATE CHARACTERISTICS AS AN INDICATOR OF FETAL STATUS DURING ANTEPARTUM PERIOD
    TRIERWEILER, MW
    FREEMAN, RK
    JAMES, J
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1976, 125 (05) : 618 - 623
  • [42] Evaluation of fetal heart rate baseline estimation method using testing signals based on a statistical model
    Kupka, T.
    Wrobel, J.
    Jezewski, J.
    Gacek, A.
    Jezewski, M.
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 434 - 437
  • [43] Feature selection using genetic algorithms for fetal heart rate analysis
    Xu, Liang
    Redman, Christopher W. G.
    Payne, Stephen J.
    Georgieva, Antoniya
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (07) : 1357 - 1371
  • [44] AUTOMATED OF ANALYZING FETAL HEART-RATE TESTS - ALREADY A GOOD ALTERNATIVE TO VISUAL ANALYSIS
    BERNARDES, J
    PEREIRA, AC
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 170 (04) : 1207 - 1208
  • [45] Baseline Fetal Heart Rate at Term in Obese and Diabetic Women and Mode of Delivery
    Kidd, Jennifer
    Gimovsky, Martin Larry
    Nazir, Munir
    Koscica, Karen
    [J]. OBSTETRICS AND GYNECOLOGY, 2018, 131 : 115S - 115S
  • [46] EFFECT OF LUMBAR EPIDURAL ANESTHESIA ON FETAL HEART-RATE BASELINE VARIABILITY
    BOEHM, FH
    WOODRUFF, LF
    GROWDON, JH
    [J]. ANESTHESIA AND ANALGESIA, 1975, 54 (06): : 779 - 782
  • [47] Computerised estimation of the baseline fetal heart rate in labour: the low frequency line
    Mongelli, M
    Dawkins, R
    Chung, T
    Sahota, D
    Spencer, JAD
    Chang, AMZ
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (10): : 1128 - 1133
  • [48] Decreased baseline variability on fetal heart rate pattern in a fetus with heterotaxy syndrome
    Yamada, Ryutaro
    Takei, Kohta
    Kaneshi, Yosuke
    Morikawa, Mamoru
    Cho, Kazutoshi
    Minakami, Hisanori
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2015, 41 (12) : 1988 - 1990
  • [49] Comparison of fetal heart rate baseline estimation by SisPorto® 2.01 and a consensus of clinicians
    Ayres-De-Campos, D
    Bernardes, J
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2004, 117 (02) : 174 - 178
  • [50] Computerized Fetal Heart Rate Baseline Estimation Based on Number and Continuity of Occurrences
    Krupa, B. Niranjana
    Ali, M. A. Mohd.
    Zahedi, E.
    [J]. 4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 162 - +