Automated fetal heart rate analysis for baseline determination using EMAU-Net

被引:4
|
作者
Liu, Mujun [1 ]
Zeng, Rongdan [2 ]
Xiao, Yahui [2 ]
Lu, Yaosheng [2 ]
Wu, Yi [1 ]
Long, Shun [3 ]
Liu, Jia [4 ]
Zheng, Zheng [5 ]
Wang, Huijin [3 ]
Bai, Jieyun [2 ]
机构
[1] Army Med Univ, Third Mil Med Univ, Coll Biomed Engn & Imaging Med, Dept Digital Med, Chongqing 400038, Peoples R China
[2] Jinan Univ, Coll Informat Sci & Technol, Dept Elect Engn, Guangzhou 510632, Peoples R China
[3] Jinan Univ, Coll Informat Sci & Technol, Dept Comp Sci, Guangzhou 510632, Peoples R China
[4] Jinan Univ, Affiliated Hosp 1, Guangzhou 510630, Peoples R China
[5] Guangzhou Med Univ, Guangzhou Women & Childrens Med Ctr, Dept Obstet, Preterm Birth Prevent & Treatment Res Unit, Guangzhou 510623, Peoples R China
关键词
Acceleration; Baseline; Convolutional Neural Network; Deceleration; Fetal Heart Rate; ALGORITHM; NETWORK;
D O I
10.1016/j.ins.2023.119281
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Automatic baseline determination is crucial for reducing the occurrence of fetal acidosis in clinical practice. However, there is a nonnegligible gap between the results of automatic baseline determination and the consensus of experts. In this paper, we propose a novel deep learning approach for baseline determination. First, potential accelerations/decelerations are recognized from the fetal heart rate and excluded by an ensemble multiattention U-Net. Then, the reference baseline and reliable interval are calculated via long- and short-term filters. Based on the filters, unreliable points for estimating the baseline are removed, and the final baseline is determined. We evaluate the performance of the proposed method on a public and a private database. Compared with state-of-the-art methods, our method yields better performance (the root mean square difference between baselines (BL. RMSD), F-measures for acceleration and deceleration (Acc/Dec. F-measures), the synthetic inconsistency coefficient (SI), and the morphological analysis discordance index (MADI) are 2.84 bpm, 0.80, 0.77, 48.9% and 3.94%, respectively) on the public database. The proposed method performs optimally in all metrics on the private database (BL. RMSD, Acc/Dec. F-measures, SI, and MADI are 1.75 bpm, 0.88, 0.80, 43.5%, and 3.11%, respectively). The experimental results indicate the effectiveness and generalizability of the proposed method.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Fetal heart rate baseline computation with a weighted median filter
    Boudet, Samuel
    de l'Aulnoit, Agathe Houze
    Demailly, Romain
    Peyrodie, Laurent
    Beuscart, Regis
    de l'Aulnoit, Denis Houze
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 114
  • [22] EFFECT OF SCOPOLAMINE ON FETAL HEART-RATE BASELINE VARIABILITY
    BOEHM, FH
    GROWDON, JH
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1974, 120 (08) : 1099 - 1104
  • [23] Robust Baseline Measurement for Reliable Fetal Heart Rate Evaluation
    Frigo, G.
    Giorgi, G.
    [J]. 2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 206 - 211
  • [24] Can the reproducibility of fetal heart rate baseline estimation be improved?
    Ayres-de-Campos, D
    Bernardes, J
    Marsal, K
    Nickelsen, C
    Makarainen, L
    Banfield, P
    Xavier, P
    Campos, I
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2004, 112 (01) : 49 - 54
  • [25] BASELINE IN HUMAN-FETAL HEART-RATE RECORDS
    DAWES, GS
    HOUGHTON, CRS
    REDMAN, CWG
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (04): : 270 - 275
  • [26] Association of Fetal Heart Rate Baseline Change and Neonatal Outcomes
    Yang, Michael
    Stout, Molly J.
    Lopez, Julia D.
    Colvin, Ryan
    Macones, George A.
    Cahill, Alison G.
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2017, 34 (09) : 879 - 886
  • [27] RAPID METHOD FOR FETAL HEART RATE DETERMINATION
    NAPOLITANI, FD
    SWARTZ, DP
    [J]. OBSTETRICS AND GYNECOLOGY, 1967, 29 (01): : 142 - +
  • [28] Magnetocardiography in the determination of fetal heart rate complexity
    Van Leeuwen, P
    Bettermann, H
    Schüssler, M
    Lange, S
    [J]. BIOMAG 96: PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON BIOMAGNETISM, VOLS I & II, 2000, : 573 - 576
  • [29] Determining Fetal Heart Rate Using Independent Component Analysis
    Szalai, Janos
    Mozes, Ferenc Emil
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTER COMMUNICATION AND PROCESSING (ICCP), 2014, : 11 - +
  • [30] Computerized fetal heart rate analysis in labor: detection of intervals with un-assignable baseline
    Georgieva, Antoniya
    Payne, Stephen J.
    Moulden, Mary
    Redman, Christopher W. G.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2011, 32 (10) : 1549 - 1560