Correction method of the fluorescence intensity of petroleum hydrocarbons in different soil types based on resonance scattering spectroscopy

被引:0
|
作者
Yang, Jinqiang [1 ,2 ,3 ]
Yang, Ruifang [1 ,3 ]
Zhao, Nanjing [1 ,3 ]
Shi, Gaoyong [1 ,2 ,3 ]
Liu, Wenqing [1 ,3 ]
机构
[1] Chinese Acad Sci, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[3] Key Lab Opt Monitoring Technol Environm Anhui Prov, Hefei 230031, Anhui, Peoples R China
关键词
Soil; Petroleum Hydrocarbons; Fluorescence spectroscopy; Resonance scattering spectroscopy; Correction; LASER-INDUCED FLUORESCENCE; PAHS;
D O I
10.1016/j.saa.2023.123174
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Soil types has an obvious impact influence on the fluorescence intensity of soil petroleum hydrocarbons. To reduce the interference caused by soil types, this paper proposes a calibration method using resonance scattering spectroscopy. To establish the correction method, 100 g/kg crude oil samples from six soil types were prepared. The mission and resonance scattering spectrum under 280 nm excitation were measured for all samples. The results showed that the fluorescence spectra and resonance scattering spectra of soil crude oil vary with different soil types. And the fluorescence peak intensity and the resonance scattering peak intensity at 360 nm of soil petroleum hydrocarbons are highly correlated in different soil types. The fluorescence peak intensity at 360 nm was divided by the resonance scattering light intensity at 360 nm to obtain the corrected fluorescence intensity, which can effectively reduce the influence of soil type on fluorescence intensity. The feasibility of correction method was further verified for different types and concentrations of soil crude oil. The results showed better linearity between the fluorescence intensity and the concentration of Petroleum Hydrocarbons after the correction (with a correlation coefficient R(2 )of 0.96) than before the correction (with R(2 )of 0.72), the mean relative prediction error of all samples decreased from 31.92 % to 4.71 % after correction. The research can provide theoretical basis and technical support for the accurate and rapid detection of Petroleum Hydrocarbons in soil by fluorescence spectroscopy.
引用
收藏
页数:6
相关论文
共 35 条
  • [31] A distinct approach to laser plasma spectroscopy through internal reference standard method with peak intensity-based self-absorption correction
    Seyede Elahe Ghoreyshi
    Hamidreza Shirvani-Mahdavi
    Seyede Zahra Shoursheini
    Applied Physics B, 2019, 125
  • [32] In situ analysis of petroleum hydrocarbons in soils by a combination of laser induced fluorescence (LIF) spectroscopy with cone penetration tests (CPT) -: Application of the OPTIMOS (Oil Pollution Transportable Independent Monitoring System) for surface and subsurface soil analysis
    Hengstermann, T
    Schultze, RH
    Wollenhaupt, H
    Lemke, M
    FIELD SCREENING EUROPE 2001, 2002, : 299 - 302
  • [33] Soil Quality Assessment of Different Land Use Types Based on TOPSIS Method in Hilly Sandy Area of Loess Plateau, Northern China
    An, Yida
    Zhang, Lei
    Wang, Qing
    Han, Yunwei
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (24)
  • [34] Calibration Transfer of Soil Total Carbon and Total Nitrogen between Two Different Types of Soils Based on Visible-Near-Infrared Reflectance Spectroscopy
    Li, Xue-Ying
    Liu, Yan
    Lv, Mei-Rong
    Zou, Yan
    Fan, Ping-Ping
    JOURNAL OF SPECTROSCOPY, 2018, 2018
  • [35] Correction to: Effects of different spectral processing methods on soil organic matter prediction based on VNIR-SWIR spectroscopy in karst areas, Southwest China
    Wu, Mengjuan
    Huang, Yuqing
    Zhao, Xin
    Jin, Jia
    Ruan, Yangchun
    JOURNAL OF SOILS AND SEDIMENTS, 2024, 24 (11) : 3789 - 3789