Correction method of the fluorescence intensity of petroleum hydrocarbons in different soil types based on resonance scattering spectroscopy

被引:0
|
作者
Yang, Jinqiang [1 ,2 ,3 ]
Yang, Ruifang [1 ,3 ]
Zhao, Nanjing [1 ,3 ]
Shi, Gaoyong [1 ,2 ,3 ]
Liu, Wenqing [1 ,3 ]
机构
[1] Chinese Acad Sci, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[3] Key Lab Opt Monitoring Technol Environm Anhui Prov, Hefei 230031, Anhui, Peoples R China
关键词
Soil; Petroleum Hydrocarbons; Fluorescence spectroscopy; Resonance scattering spectroscopy; Correction; LASER-INDUCED FLUORESCENCE; PAHS;
D O I
10.1016/j.saa.2023.123174
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Soil types has an obvious impact influence on the fluorescence intensity of soil petroleum hydrocarbons. To reduce the interference caused by soil types, this paper proposes a calibration method using resonance scattering spectroscopy. To establish the correction method, 100 g/kg crude oil samples from six soil types were prepared. The mission and resonance scattering spectrum under 280 nm excitation were measured for all samples. The results showed that the fluorescence spectra and resonance scattering spectra of soil crude oil vary with different soil types. And the fluorescence peak intensity and the resonance scattering peak intensity at 360 nm of soil petroleum hydrocarbons are highly correlated in different soil types. The fluorescence peak intensity at 360 nm was divided by the resonance scattering light intensity at 360 nm to obtain the corrected fluorescence intensity, which can effectively reduce the influence of soil type on fluorescence intensity. The feasibility of correction method was further verified for different types and concentrations of soil crude oil. The results showed better linearity between the fluorescence intensity and the concentration of Petroleum Hydrocarbons after the correction (with a correlation coefficient R(2 )of 0.96) than before the correction (with R(2 )of 0.72), the mean relative prediction error of all samples decreased from 31.92 % to 4.71 % after correction. The research can provide theoretical basis and technical support for the accurate and rapid detection of Petroleum Hydrocarbons in soil by fluorescence spectroscopy.
引用
收藏
页数:6
相关论文
共 35 条
  • [21] Digital Evaluation of Aroma Intensity and Odor Characteristics of Tea with Different Types-Based on OAV-Splitting Method
    Hu, Wenwen
    Wang, Gege
    Lin, Shunxian
    Liu, Zhijun
    Wang, Peng
    Li, Jiayu
    Zhang, Qi
    He, Haibin
    FOODS, 2022, 11 (15)
  • [22] Inversion method of organic matter content of different types of soils in black soil area based on hyperspectral indices
    Lin, Nan
    Liu, Yanlong
    Liu, Qiang
    Jiang, Ranzhe
    Ma, Xunhu
    OPEN GEOSCIENCES, 2024, 16 (01):
  • [23] Application of the method of measurement of fluorescence intensity in vivo in biological tissues for pharmacokinetic studies of different chlorin-based photosensitizers
    Shlyakhtin S.V.
    Trukhacheva T.V.
    Isakov G.A.
    Istomin Y.P.
    Biochemistry (Moscow) Supplement Series B: Biomedical Chemistry, 2010, 4 (2) : 184 - 190
  • [24] A Fast Raman Spectroscopy Classification Method for Fuels Combining the Fluorescence Background Correction Based on GCB Preprocess and Modified Hierarchical Clustering
    Yu Xing-chen
    Guan Liang
    Li Zi-cun
    Gong Ying-zhong
    Ma Jun
    Xu Xian
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (03) : 807 - 812
  • [25] Transferability of soil organic matter prediction models between different soil types based on improved standard-sample calibration transfer method
    Zhou, Ziyu
    Wei, Guangyuan
    Zhou, Ping
    Chen, Zhe
    Yan, Jiadong
    Wang, Jingshan
    JOURNAL OF APPLIED REMOTE SENSING, 2024, 18 (04)
  • [26] Quantitative attribution analysis of soil erosion in different morphological types of geomorphology in karst areas: Based on the geographical detector method
    Wang H.
    Gao J.
    Hou W.
    Gao, Jiangbo (gaojiangbo@igsnrr.ac.cn), 1674, Science Press (73): : 1674 - 1686
  • [27] SVD-based method for intensity normalization, background correction and solvent subtraction in Raman spectroscopy exploiting the properties of water stretching vibrations
    Palacky, Jan
    Mojzes, Peter
    Bok, Jiri
    JOURNAL OF RAMAN SPECTROSCOPY, 2011, 42 (07) : 1528 - 1539
  • [28] Can magnetization transfer data front different magnetic resonance imaging scanner/sequence/pulse types be standardized? an application of correction factor function method
    Kelemen, Arpad
    Dwyer, Michael G.
    Hussein, Sara
    Stosic, Milena
    Liang, Yulan
    Zivadinov, Robert
    MULTIPLE SCLEROSIS JOURNAL, 2008, 14 : S111 - S111
  • [29] APPLICATION OF A METHOD FOR MATRIX CORRECTION USING COMPTON-SCATTERING FOR THE QUANTITATIVE-DETERMINATION OF METALS IN SILICA BY WAVELENGTH DISPERSIVE-X-RAY FLUORESCENCE SPECTROSCOPY (WDXRF)
    LUHRMANN, M
    WEGENER, F
    KETTRUP, A
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 323 (02): : 132 - 134
  • [30] A distinct approach to laser plasma spectroscopy through internal reference standard method with peak intensity-based self-absorption correction
    Ghoreyshi, Seyede Elahe
    Shirvani-Mahdavi, Hamidreza
    Shoursheini, Seyede Zahra
    APPLIED PHYSICS B-LASERS AND OPTICS, 2019, 125 (07):