A very thin MRPC developed for TOF-PET

被引:0
|
作者
Liu, J. [1 ]
Wang, Y. [1 ]
Guo, B. [1 ]
Han, D. [1 ]
Li, Y. [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 02期
基金
中国国家自然科学基金;
关键词
Gaseous detectors; Resistive-plate chambers;
D O I
10.1088/1748-0221/19/02/C02068
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
PET (Positron Emission Tomography) is a medical molecular imaging modality employed in cancer diagnosis and monitoring. Multi -gap Resistive Plate Chambers (MRPCs) are utilized in Time of Flight (TOF)-PET due to their superior time resolution. Our research group has successfully developed a 4 -chamber 32 -gap MRPC prototype with 0.128 mm gap thickness. The measured time resolution for cosmic rays is 20 ps, while the time resolution for the time difference between 0.511 MeV photon pairs is 193 ps Full Width at Half Maximum (FWHM). The 23.6 mm thickness of the MRPC prototype will affect the time resolution. To investigate the influence of the number and total thickness of gas gaps on the time resolution, Geant4 software is used to simulate the interaction between particles (such as cosmic rays and photons) and MRPC detectors. Most of the gamma photons interact with the resistive plates in MRPCs. It is ejected mostly a Compton electron into one gas gap, causing the gas ionization. In this paper, two 8 -gap MRPC prototypes with 0.128 mm gap thickness and 4.2 mm total thickness are fabricated and tested. The time resolution of 39 ps for cosmic rays and 166 ps FWHM for 0.511 MeV photons is obtained using the fast front-end amplifier and waveform acquisition system. So, a real time PET image can be obtained with a pair of MRPCs, and the detection efficiency for gamma can be improved by increasing the number of thin MRPCs.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT-Initial Results
    Zeimpekis, Konstantinos G.
    Barbosa, Felipe
    Huellner, Martin
    ter Voert, Edwin
    Davison, Helen
    Veit-Haibach, Patrick
    Delso, Gaspar
    MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (05) : 735 - 744
  • [32] The TT-PET project: a thin TOF-PET scanner based on fast novel silicon pixel detectors
    Bandi, Y.
    Benoit, M.
    Cadoux, F. R.
    Forshaw, D. C.
    Hanni, R.
    Hayakawa, D.
    Iacobucci, G.
    Michal, S.
    Miucci, A.
    Paolozzi, L.
    Ratib, O.
    Ripiccini, E.
    Tognina, C.
    Valerio, P.
    Weber, M.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [33] TOF-PET detector concept based on organic scintillators
    Moskal, Pawel
    Bednarski, Tomasz
    Bialas, Piotr
    Ciszewska, Marta
    Czerwinski, Eryk
    Heczko, Andrzej
    Kajetanowicz, Marcin
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Konopka-Cupial, Gabriela
    Korcyl, Grzegorz
    Krzemien, Wojciech
    Lojek, Konrad
    Majewski, Jerzy
    Migdal, Wojciech
    Molenda, Marcin
    Niedzwiecki, Szymon
    Palka, Marek
    Rudy, Zbigniew
    Salabura, Piotr
    Silarski, Michal
    Slomski, Artur
    Smyrski, Jerzy
    Zdebik, Jaroslaw
    Zielinski, Marcin
    NUCLEAR MEDICINE REVIEW, 2012, 15 : C81 - C84
  • [34] Towards 50 ps TOF-PET for Brain imaging
    Harmon, Eric S.
    Thompson, Michael O.
    Schmidtlein, C. Ross
    Turner, James N.
    Krol, Andrzej
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [35] TOF-PET/MR和TOF-PET/CT在体部恶性肿瘤SUV值的比较
    宋天彬
    卢洁
    崔碧霄
    马杰
    杨宏伟
    马蕾
    梁志刚
    中国医学影像技术, 2017, 33 (09) : 1401 - 1406
  • [36] Strip-PET: a novel detector concept for the TOF-PET scanner
    Moskal, Pawel
    Bednarski, Tomasz
    Bialas, Piotr
    Ciszewska, Marta
    Czerwinski, Eryk
    Heczko, Andrzej
    Kajetanowicz, Marcin
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Konopka-Cupial, Gabriela
    Korcyl, Grzegorz
    Krzemien, Wojciech
    Lojek, Konrad
    Majewski, Jerzy
    Migdal, Wojciech
    Molenda, Marcin
    Niedzwiecki, Szymon
    Palka, Marek
    Rudy, Zbigniew
    Salabura, Piotr
    Silarski, Michal
    Slomski, Artur
    Smyrski, Jerzy
    Zdebik, Jaroslaw
    Zielinski, Marcin
    NUCLEAR MEDICINE REVIEW, 2012, 15 : C68 - C69
  • [37] J-PET analysis framework for the prototype TOF-PET detector
    Krzemien, Wojciech
    Silarski, Michal
    Stola, Karol
    Trybek, Damian
    Bednarski, Tomasz
    Bialas, Piotr
    Czerwinski, Eryk
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Korcyl, Grzegorz
    Kowal, Jakub
    Kowalski, Pawel
    Kozik, Tomasz
    Molenda, Marcin
    Moskal, Pawel
    Niedzwiecki, Szymon
    Palka, Marek
    Pawlik, Monika
    Raczynski, Lech
    Rudy, Zbigniew
    Salabura, Piotr
    Sharma, Neha Gupta
    Slomski, Artur
    Smyrski, Jerzy
    Strzelecki, Adam
    Wislicki, Wojciech
    Zielinski, Marcin
    Zon, Natalia
    BIO-ALGORITHMS AND MED-SYSTEMS, 2014, 10 (01) : 33 - 36
  • [38] Hybrid TOF-PET/MRI local transceiver coil
    Glowacz, B.
    Zielinski, M.
    Alfs, D.
    Bednarski, T.
    Bialas, P.
    Czerwinski, E.
    Gajos, A.
    Gorgol, M.
    Jasinska, B.
    Kaminska, D.
    Kaplon, L.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krzemien, W.
    Kubicz, E.
    Mohammed, M.
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Palka, M.
    Raczynski, L.
    Rudy, Z.
    Rundel, O.
    Sharma, N. G.
    Silarski, M.
    Slomski, A.
    Strzelecki, A.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Moskal, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S47 - S48
  • [39] A 40-Channel Readout ASIC for ToF-PET
    Ritzert, Michael
    Fischer, Peter
    Peric, Ivan
    Solf, Torsten
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4307 - +
  • [40] Performance Characterization of MPPC Modules for TOF-PET Applications
    Goertzen, Andrew L.
    Van Elburg, Devin
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (04) : 475 - 482