Calculation of biological effectiveness of SOBP proton beams: a TOPAS Monte Carlo study

被引:0
|
作者
Chattaraj, Arghya [1 ,2 ]
Selvam, T. Palani [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Hlth Safety & Environm Grp, Mumbai 400085, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, India
关键词
relative biological effectiveness; TOPAS Monte Carlo; microdosimetry; SOBP protons; MICRODOSIMETRIC-KINETIC-MODEL; EFFECTIVENESS RBE VALUES; THERAPY BEAMS; CELL-SURVIVAL; SIMULATION; ENERGIES; REPAIR; V79;
D O I
10.1088/2057-1976/ad2b02
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. This study aims to investigate the biological effectiveness of Spread-Out Bragg-Peak (SOBP) proton beams with initial kinetic energies 50-250 MeV at different depths in water using TOPAS Monte Carlo code. Approach. The study modelled SOBP proton beams using TOPAS time feature. Various LET-based models and Repair-Misrepair-Fixation model were employed to calculate Relative Biological Effectiveness (RBE) for V79 cell lines at different on-axis depths based on TOPAS. Microdosimetric Kinetic Model and biological weighting function-based models, which utilize microdosimetric distributions, were also used to estimate the RBE. A phase-space-based method was adopted for calculating microdosimetric distributions. Main results. The trend of variation of RBE with depth is similar in all the RBE models, but the absolute RBE values vary based on the calculation models. RBE sharply increases at the distal edge of SOBP proton beams. In the entrance region of all the proton beams, RBE values at 4 Gy i.e. RBE(4 Gy) resulting from different models are in the range of 1.04-1.07, comparable to clinically used generic RBE of 1.1. Moving from the proximal to distal end of the SOBP, RBE(4 Gy) is in the range of 1.15-1.33, 1.13-1.21, 1.11-1.17, 1.13-1.18 and 1.17-1.21, respectively for 50, 100, 150, 200 and 250 MeV SOBP beams, whereas at the distal dose fall-off region, these values are 1.68, 1.53, 1.44, 1.42 and 1.40, respectively. Significance. The study emphasises application of depth-, dose- and energy- dependent RBE values in clinical application of proton beams.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Monte Carlo calculation of beam quality correction factors in proton beams using TOPAS/GEANT4
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05):
  • [2] Macro Monte Carlo for dose calculation of proton beams
    Fix, Michael K.
    Frei, Daniel
    Volken, Werner
    Born, Ernst J.
    Aebersold, Daniel M.
    Manser, Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2027 - 2044
  • [3] Monte Carlo simulations of cell survival in proton SOBP
    Sebastian, Salgado Maldonado
    Alejandro, Carabe
    Ignacio, Espinoza
    Sophia, Galvez
    Pia, Valenzuela Maria
    Andrea, Russomando
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (19):
  • [4] Comparison of Proton Treatment Planning and Monte Carlo Calculation Using TOPAS for Liver Cancer
    Moteabbed, M.
    Schuemann, J.
    Paganetti, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3813 - 3813
  • [5] Simplified Monte Carlo dose calculation for therapeutic proton beams
    Kohno, R
    Sakae, T
    Takada, Y
    Matsumoto, K
    Matsuda, H
    Nohtomi, A
    Terunuma, T
    Tsunashima, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2002, 41 (3A): : L294 - L297
  • [6] Estimating the relative biological effectiveness of light ions using TOPAS monte carlo simulation
    Efendi, M. Arif
    Sakata, D.
    Keat, Y. C.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2024, 22 (03):
  • [7] Mechanistic Calculation of Relative Biological Effectiveness of Proton Irradiation Via Microscopic Monte Carlo Simulations
    Xing, M.
    Lai, Y.
    Chi, Y.
    Jia, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E598 - E598
  • [8] Monte Carlo calculation of perturbation correction factors for air-filled ionization chambers in clinical proton beams using TOPAS/GEANT
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2021, 31 (02): : 175 - 191
  • [9] Monte Carlo Calculation of Perturbation Correction Factors for AirFilled Ionization Chambers in Clinical Proton Beams Using TOPAS/GEANT4
    Baumann, K.
    Kaupa, S.
    Engenhart-Cabillic, R.
    Zink, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E281 - E282
  • [10] Proton dose deposition in heterogeneous media: A TOPAS Monte Carlo simulation study
    Li, Jie
    Cui, Xiangli
    Liu, Lingling
    Li, Bingbing
    Fei, Zhenle
    Han, Wei
    APPLIED RADIATION AND ISOTOPES, 2025, 217