Calculation of biological effectiveness of SOBP proton beams: a TOPAS Monte Carlo study

被引:0
|
作者
Chattaraj, Arghya [1 ,2 ]
Selvam, T. Palani [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Hlth Safety & Environm Grp, Mumbai 400085, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, India
关键词
relative biological effectiveness; TOPAS Monte Carlo; microdosimetry; SOBP protons; MICRODOSIMETRIC-KINETIC-MODEL; EFFECTIVENESS RBE VALUES; THERAPY BEAMS; CELL-SURVIVAL; SIMULATION; ENERGIES; REPAIR; V79;
D O I
10.1088/2057-1976/ad2b02
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. This study aims to investigate the biological effectiveness of Spread-Out Bragg-Peak (SOBP) proton beams with initial kinetic energies 50-250 MeV at different depths in water using TOPAS Monte Carlo code. Approach. The study modelled SOBP proton beams using TOPAS time feature. Various LET-based models and Repair-Misrepair-Fixation model were employed to calculate Relative Biological Effectiveness (RBE) for V79 cell lines at different on-axis depths based on TOPAS. Microdosimetric Kinetic Model and biological weighting function-based models, which utilize microdosimetric distributions, were also used to estimate the RBE. A phase-space-based method was adopted for calculating microdosimetric distributions. Main results. The trend of variation of RBE with depth is similar in all the RBE models, but the absolute RBE values vary based on the calculation models. RBE sharply increases at the distal edge of SOBP proton beams. In the entrance region of all the proton beams, RBE values at 4 Gy i.e. RBE(4 Gy) resulting from different models are in the range of 1.04-1.07, comparable to clinically used generic RBE of 1.1. Moving from the proximal to distal end of the SOBP, RBE(4 Gy) is in the range of 1.15-1.33, 1.13-1.21, 1.11-1.17, 1.13-1.18 and 1.17-1.21, respectively for 50, 100, 150, 200 and 250 MeV SOBP beams, whereas at the distal dose fall-off region, these values are 1.68, 1.53, 1.44, 1.42 and 1.40, respectively. Significance. The study emphasises application of depth-, dose- and energy- dependent RBE values in clinical application of proton beams.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] The Proton Therapy Nozzles at Samsung Medical Center: A Monte Carlo Simulation Study using TOPAS
    Chung, Kwangzoo
    Kim, Jinsung
    Kim, Dae-Hyun
    Ahn, Sunghwan
    Han, Youngyih
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 170 - 174
  • [22] Microdosimetric calculation of relative biological effectiveness for design of therapeutic proton beams
    Kase, Yuki
    Yamashita, Wataru
    Matsufuji, Naruhiro
    Takada, Kenta
    Sakae, Takeji
    Furusawa, Yoshiya
    Yamashita, Haruo
    Murayama, Shigeyuki
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (03) : 485 - 493
  • [23] Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization
    Carlsson, AK
    Andreo, P
    Brahme, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06): : 1033 - 1053
  • [24] Monte Carlo calculation of beam quality correction factors in proton beams using PENH
    Goma, Carles
    Sterpin, Edmond
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18):
  • [25] Monte Carlo calculation of beam quality correction factors in proton beams using FLUKA
    Baumann, Kilian-Simon
    Derksen, Larissa
    Witt, Matthias
    Burg, Jan Michael
    Engenhart-Cabillic, Rita
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (17):
  • [26] Proton Beam Delivery to a Moving Lung Tumor and Monte Carlo Simulation with TOPAS
    Coruh, M.
    Demez, N.
    Ewell, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3483 - 3483
  • [27] Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy
    Testa, M.
    Schuemann, J.
    Lu, H. -M.
    Shin, J.
    Faddegon, B.
    Perl, J.
    Paganetti, H.
    MEDICAL PHYSICS, 2013, 40 (12)
  • [28] Modeling of a Compact Proton Therapy System Using TOPAS Monte Carlo Code
    Prusator, M.
    Ahmad, S.
    Chen, Y.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [29] TOPAS Monte Carlo simulation for double scattering proton therapy and dosimetric evaluation
    Liu, Hongdong
    Li, Zuofeng
    Slopsema, Roelf
    Hong, Liu
    Pei, Xi
    Xu, Xie George
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 62 : 53 - 62
  • [30] Pencil-Beam Versus Monte Carlo Based Dose Calculation for Proton Therapy Patients with Complex Geometries. Clinical Use of the TOPAS Monte Carlo System
    Schuemann, J.
    Shin, J.
    Perl, J.
    Grassberger, C.
    Verburg, J.
    Faddegon, B.
    Paganetti, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3820 - 3820