Combining electrical capacitance and impedance tomography in monitoring processes

被引:3
|
作者
Klosowski, Grzegorz [1 ]
Adamkiewicz, Przemyslaw [2 ]
Niderla, Konrad [2 ,3 ]
机构
[1] Lublin Univ Technol, Nadbystrzycka 38A, Lublin, Poland
[2] Univ Econ & Innovat, Projektowa 4, Lublin, Poland
[3] Netrix SA, Ctr Res & Dev, Lublin, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2023年 / 99卷 / 02期
关键词
machine learning; electrical impedance tomography; electrical capacitance tomography; process tomography; hybrid tomography;
D O I
10.15199/48.2023.02.28
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The presented research describes an experiment aimed at answering the question of whether the combination of two types of tomographic measurements, namely electrical impedance tomography (EIT) and electrical capacitance tomography (ECT), will improve the quality of the reconstruction in comparison to the tomographic images obtained with both methods considered separately. For this purpose, appropriate tests were carried out, which showed that, in fact, magnification of the measurement vector by combining EIT and ECT measurements increases the quality of the reconstruction.
引用
收藏
页码:161 / 164
页数:4
相关论文
共 50 条
  • [41] BETS - a bladder monitoring system using electrical impedance tomography
    Baran, Bartlomiej
    Wojcik, Dariusz
    Oleszek, Michal
    Vejar, Andres
    Rymarczyk, Tomasz
    PROCEEDINGS OF THE TWENTIETH ACM CONFERENCE ON EMBEDDED NETWORKED SENSOR SYSTEMS, SENSYS 2022, 2022, : 804 - 805
  • [42] Monitoring retroperitoneal bleeding model of piglets by electrical impedance tomography
    You, Fusheng
    Shuai, Wanjun
    Shi, Xuetao
    Fu, Feng
    Liu, Ruigang
    Dong, Xiuzhen
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1185 - +
  • [43] Monitoring patients with left ventricular failure by electrical impedance tomography
    Noble, TJ
    Morice, AH
    Channer, KS
    Milnes, P
    Harris, ND
    Brown, BH
    EUROPEAN JOURNAL OF HEART FAILURE, 1999, 1 (04) : 379 - 384
  • [44] Image reconstruction for lung monitoring in wearable electrical impedance tomography
    Wocik, Dariusz
    Stefaniak, Barbara
    Wos, Michal
    Kiczek, Bartlomiej
    Rymarczyk, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (03): : 106 - 109
  • [45] A Novel Method for Monitoring Data Quality in Electrical Impedance Tomography
    Adler, Andy
    Grychtol, Bartlomiej
    Gaggero, Pascal
    Justiz, Joern
    Koch, Volker
    Mamatjan, Yasin
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [46] Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?
    Steffen Leonhardt
    Burkhard Lachmann
    Intensive Care Medicine, 2012, 38 : 1917 - 1929
  • [47] Enhancing the imaging performance of electrical capacitance tomography for monitoring osseointegrated prostheses
    Gupta, Sumit
    Zhang, Tianjiao
    Loh, Kenneth J.
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2019, 2019, 10970
  • [48] Capacitance measuring circuit for electrical capacitance tomography
    Yu, XY
    Zhao, J
    Zhao, X
    Zheng, GB
    Chen, DY
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, 2002, : 429 - 432
  • [49] Electrical capacitance tomography - A perspective
    Marashdeh, Q.
    Fan, L. -S.
    Du, B.
    Warsito, W.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (10) : 3708 - 3719
  • [50] Electrical capacitance volume tomography
    Warsito, Warsito
    Marashdeh, Qussai
    Fan, Liang-Shih
    IEEE SENSORS JOURNAL, 2007, 7 (3-4) : 525 - 535