Monitoring retroperitoneal bleeding model of piglets by electrical impedance tomography

被引:0
|
作者
You, Fusheng [1 ]
Shuai, Wanjun
Shi, Xuetao
Fu, Feng
Liu, Ruigang
Dong, Xiuzhen [1 ]
机构
[1] Fourth Mil Med Univ, Dept Biomed Engn, Xian 710032, Peoples R China
关键词
D O I
10.1109/IEMBS.2008.4649374
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To investigate continuous monitoring capacity of electrical impedance tomography (EIT) for retroperitoneal bleeding, studies were carried out on six anesthetized piglet's bleeding model produced by injecting anticoagulated blood into renal region. For each subject, total blood of about 200 ml was injected within time periods ranging from tens of minutes to several hours. The simulated bleeding processes were detected and monitored by EIT system with sixteen electrodes at a rate of one image per second. EIT images were reconstructed by dynamic back-projection algorithm. The results showed that impedance changes caused by bleeding could be revealed by EIT images.
引用
收藏
页码:1185 / +
页数:2
相关论文
共 50 条
  • [1] Application of Electrical Impedance Tomography for Continuous Monitoring of Retroperitoneal Bleeding After Blunt Trauma
    Wanjun Shuai
    Fusheng You
    Hongyi Zhang
    Wei Zhang
    Feng Fu
    Xuetao Shi
    Ruigang Liu
    Tingyi Bao
    Xiuzhen Dong
    Annals of Biomedical Engineering, 2009, 37 : 2373 - 2379
  • [2] Application of Electrical Impedance Tomography for Continuous Monitoring of Retroperitoneal Bleeding After Blunt Trauma
    Shuai, Wanjun
    You, Fusheng
    Zhang, Hongyi
    Zhang, Wei
    Fu, Feng
    Shi, Xuetao
    Liu, Ruigang
    Bao, Tingyi
    Dong, Xiuzhen
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (11) : 2373 - 2379
  • [3] Image monitoring for an intraperitoneal bleeding model of pigs using electrical impedance tomography
    Shuai Wanjun
    You Fusheng
    Zhang Wei
    Zhang Hongyi
    Fu Feng
    Shi Xuetao
    Liu Ruigang
    Xu Canhua
    Dong Xiuzhen
    Bao Tingyi
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (02) : 217 - 225
  • [4] Applying electrical impedance tomography to dynamically monitor retroperitoneal bleeding in a renal trauma patient
    Fusheng You
    Xuetao Shi
    Wanjun Shuai
    Hongyi Zhang
    Wei Zhang
    Feng Fu
    Ruigang Liu
    Canhua Xu
    Tingyi Bao
    Xiuzhen Dong
    Intensive Care Medicine, 2013, 39 : 1159 - 1160
  • [5] Applying electrical impedance tomography to dynamically monitor retroperitoneal bleeding in a renal trauma patient
    You, Fusheng
    Shi, Xuetao
    Shuai, Wanjun
    Zhang, Hongyi
    Zhang, Wei
    Fu, Feng
    Liu, Ruigang
    Xu, Canhua
    Bao, Tingyi
    Dong, Xiuzhen
    INTENSIVE CARE MEDICINE, 2013, 39 (06) : 1159 - 1160
  • [6] Experiment research of electrical impedance tomography for monitoring the intraperitoneal bleeding of rabbit in vivo
    You Fusheng
    Dong Xiuzhen
    Li Zheng
    Shi Xuetao
    Zhang Guopeng
    Zhao Daqing
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3929 - 3931
  • [7] Electrical Impedance Tomography for Hemodynamic Monitoring
    Leonhardt, Steffen
    Pikkemaat, Robert
    Stenqvist, Ola
    Lundin, Stefan
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 122 - 125
  • [8] Monitoring lungs with electrical impedance tomography
    Bevilacqua, Joyce Da Silva
    Yoshikawaz, Roberto Masaishi
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2007, 15 (04) : 325 - 337
  • [9] Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model
    Fagerberg, A.
    Stenqvist, O.
    Aneman, A.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (02) : 152 - 158
  • [10] Wearable electrical impedance tomography for chest monitoring
    Frerichs, Inez
    Vogt, Barbara
    Wacker, Josias
    Paradiso, Rita
    Braun, Fabian
    Rapin, Michael
    Caldani, Laura
    Chetelat, Olivier
    Weiler, Norbert
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56