A single-phase solid-state fault current limiter: Simulation and experimental study

被引:0
|
作者
Kucukaydin, Baris [1 ]
Isen, Evren [2 ]
Arikan, Oktay [3 ]
机构
[1] Kirklareli Univ, Dept Elect & Elect Engn, TR-39000 Kirklareli, Turkiye
[2] Bandirma Onyedi Eylul Univ, Dept Elect Engn, TR-10200 Bandirma, Turkiye
[3] Yildiz Tech Univ, Dept Elect Engn, TR-34220 Istanbul, Turkiye
关键词
Single-Phase Fault Current Limiter; Parallel Resonance; Series Resonance; Phase To Ground Fault; CAPABILITY; RIDE;
D O I
10.14744/sigma.2024.00017
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Various methods are used to reduce fault currents in fault situations occurring in power systems. In this study, a developed single-phase power electronics -based solid-state fault current limiter is presented. The proposed single-phase solid-state fault current limiter is designed as preliminary prototype of the three-phase low voltage solid-state fault current limiter. The maximum current and voltage capability of the fault current limiter is 16 A and 480 V. This limiter works according to the principle of series and parallel resonance. In normal operation, the current passes through the inductance and capacitor, which are in series resonance. Thus, extra voltage drops and power loss in the system are prevented. In the event of a fault, the limiter switches to parallel resonance, and its impedance increases. Therefore, the fault current is decreased. The developed circuit and control algorithm reduces the first peak of fault current with a rather high percentage by comparison with the fault current without fault current limiter. In addition, the amplitude of current oscillation is decreased, and the current is recovered in a short time because the control algorithm determines the fault start and end time fast. The effect of the limiter is demonstrated with the simulation results in Matlab/Simulink. The simulation results are verified with the application study carried out in the laboratory environment. The fault current reaches up to 58.5 A in case of fault current limiter is not used, whereas the developed fault current limiter suppresses the current to around 9 A. The value of maximum fault current decreases to 15% according to the non -fault current limiter used situation. In the study, detailed application notes of the limiter circuit are shared.
引用
收藏
页码:164 / 176
页数:13
相关论文
共 50 条
  • [31] Single-phase fault current calculations
    Dunn, I
    [J]. IEE REVIEW, 1996, 42 (05): : 184 - 184
  • [32] Reliability analysis of component-level redundant topologies for solid-state fault current limiter
    Farhadi, Masoud
    Abapour, Mehdi
    Mohammadi-Ivatloo, Behnam
    [J]. INTERNATIONAL JOURNAL OF ELECTRONICS, 2018, 105 (04) : 541 - 558
  • [33] Simulation study of bridge type solid state fault current limiter for high-voltage power network
    Chen, G
    Jiang, DZ
    Wu, ZL
    Lu, ZY
    [J]. 2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 2521 - 2526
  • [34] Bridge-Type Solid-State Fault Current Limiter Based on AC/DC Reactor
    Radmanesh, Hamid
    Fathi, Seyed Hamid
    Gharehpetian, G. B.
    Heidary, Amir
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (01) : 200 - 209
  • [35] SINGLE-PHASE SOLID-STATE COMPENSATORS OF THE PASSIVE COMPONENT OF INSTANTANEOUS POWER
    LABUNTSOV, VA
    ZHANG, DR
    [J]. ELECTRICAL TECHNOLOGY, 1993, (04): : 119 - 139
  • [36] Stability Assessment Extensions for Single-Phase Distribution Solid-State Transformers
    Shah, D. G.
    Crow, M. L.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1636 - 1638
  • [37] Evaluation of DC-AC Single-Phase Solid-State Transformers
    Bosso, J.
    Llomplat, M.
    Oggier, G.
    Garcia, G.
    [J]. IEEE LATIN AMERICA TRANSACTIONS, 2019, 17 (05) : 708 - 717
  • [38] Simulation research on the effect of the paralleled compensating capacitor on the solid state fault current limiter operation
    Jin, Xin
    Jiang, Dao-Zhuo
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (04): : 54 - 57
  • [39] OPTIMUM FILTER DESIGN FOR A SINGLE-PHASE SOLID-STATE UPS SYSTEM
    DEWAN, SB
    ZIOGAS, PD
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1979, 15 (06) : 664 - 669
  • [40] Experiments with a 6.6kV/1kA single-phase superconducting fault current limiter
    Yazawa, T
    Yoneda, E
    Nomura, S
    Tsurunaga, K
    Urata, M
    Ohkuma, T
    Honjo, S
    Iwata, Y
    Hara, T
    [J]. APPLIED SUPERCONDUCTIVITY 1997, VOLS 1 AND 2: VOL 1: SMALL SCALE AND ELECTRONIC APPLICATIONS; VOL 2: LARGE SCALE AND POWER APPLICATIONS, 1997, (158): : 1183 - 1186