List-Mode PET Image Reconstruction Using Deep Image Prior

被引:12
|
作者
Ote, Kibo [1 ]
Hashimoto, Fumio [1 ]
Onishi, Yuya [1 ]
Isobe, Takashi [1 ]
Ouchi, Yasuomi [2 ]
机构
[1] Hamamatsu Photon KK, Cent Res Lab, Hamamatsu 4348601, Japan
[2] Hamamatsu Univ, Preeminent Med Photon Educ & Res Ctr, Dept Biofunct Imaging, Sch Med, Hamamatsu 4313192, Japan
关键词
Image reconstruction; Positron emission tomography; Electronics packaging; Convolutional neural networks; Deep learning; Optimization; Heuristic algorithms; Deep neural network; image recon-struction; list-mode; positron emission tomography; unsupervised learning; MOTION-COMPENSATION; ALGORITHMS; DESIGN; OSEM;
D O I
10.1109/TMI.2023.3239596
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
List-mode positron emission tomography (PET) image reconstruction is an important tool for PET scanners with many lines-of-response and additional information such as time-of-flight and depth-of-interaction. Deep learning is one possible solution to enhance the quality of PET image reconstruction. However, the application of deep learning techniques to list-mode PET image reconstruction has not been progressed because list data is a sequence of bit codes and unsuitable for processing by convolutional neural networks (CNN). In this study, we propose a novel list-mode PET image reconstruction method using an unsupervised CNN called deep image prior (DIP) which is the first trial to integrate list-mode PET image reconstruction and CNN. The proposed list-mode DIP reconstruction (LM-DIPRecon) method alternatively iterates the regularized list-mode dynamic row action maximum likelihood algorithm (LM-DRAMA) and magnetic resonance imaging conditioned DIP (MR-DIP) using an alternating direction method of multipliers. We evaluated LM-DIPRecon using both simulation and clinical data, and it achieved sharper images and better tradeoff curves between contrast and noise than the LM-DRAMA, MR-DIP and sinogram-based DIPRecon methods. These results indicated that the LM-DIPRecon is useful for quantitative PET imaging with limited events while keeping accurate raw data information. In addition, as list data has finer temporal information than dynamic sinograms, list-mode deep image prior reconstruction is expected to be useful for 4D PET imaging and motion correction.
引用
收藏
页码:1822 / 1834
页数:13
相关论文
共 50 条
  • [41] List-Mode Wavelet-Based Multiresolution Image Reconstruction for Compton Imaging
    Frandes, Mirela
    Maxim, Voichita
    Prost, Remy
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3781 - 3785
  • [42] Dynamic PET Image Reconstruction Using Nonnegative Matrix Factorization Incorporated With Deep Image Prior
    Yokota, Tatsuya
    Kawai, Kazuya
    Sakata, Muneyuki
    Kimura, Yuichi
    Hontani, Hidekata
    2019 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV 2019), 2019, : 3126 - 3135
  • [43] Impact of list-mode reconstruction and image-space point spread function correction on PET image contrast and quantitative value using SiPM-based PET/CT system
    Shirakawa, Yuya
    Matsutomo, Norikazu
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (03) : 384 - 396
  • [44] Impact of list-mode reconstruction and image-space point spread function correction on PET image contrast and quantitative value using SiPM-based PET/CT system
    Yuya Shirakawa
    Norikazu Matsutomo
    Radiological Physics and Technology, 2023, 16 : 384 - 396
  • [45] Optimization-Based Image Reconstruction From Low-Count, List-Mode TOF-PET Data
    Zhang, Zheng
    Rose, Sean
    Ye, Jinghan
    Perkins, Amy E.
    Chen, Buxin
    Kao, Chien-Min
    Sidky, Emil Y.
    Tung, Chi-Hua
    Pan, Xiaochuan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (04) : 936 - 946
  • [46] PET Image Reconstruction Incorporating Deep Image Prior and a Forward Projection Model
    Hashimoto, Fumio
    Ote, Kibo
    Onishi, Yuya
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (08) : 841 - 846
  • [47] Efficient Rendering of Regions of Response in List-Mode Reconstruction for PET
    Sportelli, Giancarlo
    Ortuno, Juan E.
    Santos, Andres
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4219 - 4221
  • [48] List-mode reconstruction in 2D strip PET
    Bialas, Piotr
    Kowal, Jakub
    Strzelecki, Adam
    Bednarski, Tomasz
    Czerwinski, Eryk
    Giergiel, Krzysztof
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Korcyl, Grzegorz
    Kowalski, Pawel
    Kozik, Tomasz
    Krzemien, Wojciech
    Molenda, Marcin
    Moskal, Ines
    Moskal, Pawel
    Niedzwiecki, Szymon
    Palka, Marek
    Pawlik, Monika
    Raczynski, Lech
    Rudy, Zbigniew
    Salabura, Piotr
    Sharma, Neha G.
    Silarski, Michal
    Slomski, Artur
    Smyrski, Jerzy
    Szymanski, Konrad
    Wislicki, Wojciech
    Witkowski, Piotr
    Zielinski, Marcin
    Zon, Natalia
    BIO-ALGORITHMS AND MED-SYSTEMS, 2014, 10 (01) : 9 - 12
  • [49] List-mode reconstruction for TOF PET by estimating annihilation positions
    Kao, Chien-Min
    Kim, Heejong
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2402 - 2406
  • [50] A Preliminary Study on Optimization-Based Image Reconstruction from Sparse, List-Mode TOF-PET Data
    Zhang, Zheng
    Rose, Sean
    Chen, Buxin
    Perkins, Amy E.
    Kao, Chien-Min
    Sidky, Emil Y.
    Manjeshwar, Ravindra M.
    Pan, Xiaochuan
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,