List-Mode PET Image Reconstruction Using Deep Image Prior

被引:12
|
作者
Ote, Kibo [1 ]
Hashimoto, Fumio [1 ]
Onishi, Yuya [1 ]
Isobe, Takashi [1 ]
Ouchi, Yasuomi [2 ]
机构
[1] Hamamatsu Photon KK, Cent Res Lab, Hamamatsu 4348601, Japan
[2] Hamamatsu Univ, Preeminent Med Photon Educ & Res Ctr, Dept Biofunct Imaging, Sch Med, Hamamatsu 4313192, Japan
关键词
Image reconstruction; Positron emission tomography; Electronics packaging; Convolutional neural networks; Deep learning; Optimization; Heuristic algorithms; Deep neural network; image recon-struction; list-mode; positron emission tomography; unsupervised learning; MOTION-COMPENSATION; ALGORITHMS; DESIGN; OSEM;
D O I
10.1109/TMI.2023.3239596
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
List-mode positron emission tomography (PET) image reconstruction is an important tool for PET scanners with many lines-of-response and additional information such as time-of-flight and depth-of-interaction. Deep learning is one possible solution to enhance the quality of PET image reconstruction. However, the application of deep learning techniques to list-mode PET image reconstruction has not been progressed because list data is a sequence of bit codes and unsuitable for processing by convolutional neural networks (CNN). In this study, we propose a novel list-mode PET image reconstruction method using an unsupervised CNN called deep image prior (DIP) which is the first trial to integrate list-mode PET image reconstruction and CNN. The proposed list-mode DIP reconstruction (LM-DIPRecon) method alternatively iterates the regularized list-mode dynamic row action maximum likelihood algorithm (LM-DRAMA) and magnetic resonance imaging conditioned DIP (MR-DIP) using an alternating direction method of multipliers. We evaluated LM-DIPRecon using both simulation and clinical data, and it achieved sharper images and better tradeoff curves between contrast and noise than the LM-DRAMA, MR-DIP and sinogram-based DIPRecon methods. These results indicated that the LM-DIPRecon is useful for quantitative PET imaging with limited events while keeping accurate raw data information. In addition, as list data has finer temporal information than dynamic sinograms, list-mode deep image prior reconstruction is expected to be useful for 4D PET imaging and motion correction.
引用
收藏
页码:1822 / 1834
页数:13
相关论文
共 50 条
  • [31] A Fully 4D Mesh Parameterisation PET Image Reconstruction Algorithm for List-Mode Data
    Bickell, Matthew G.
    Buffler, Andy
    Govender, Indresan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2620 - 2624
  • [32] List-mode image reconstruction for the high resolution ClearPET™ neuro system
    Musmann, Patrick
    Pietrzyk, Uwe
    Schramm, Nils
    Weber, Simone
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1770 - 1773
  • [33] Accelerated Regularised List-Mode PET Reconstruction Using Subset Relaxation
    Spangler-Bickell, Matthew G.
    Deller, Timothy
    Jansen, Floris
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [34] Uncertainty-Informed Bayesian PET Image Reconstruction Using a Deep Image Prior
    Sudarshan, Viswanath P.
    Reddy, K. Pavan Kumar
    Singh, Mohana
    Gubbi, Jayavardhana
    Pal, Arpan
    MACHINE LEARNING FOR MEDICAL IMAGE RECONSTRUCTION (MLMIR 2022), 2022, 13587 : 145 - 155
  • [35] Efficient fully 3D list-mode TOF PET image reconstruction using a factorized system matrix with an image domain resolution model
    Zhou, Jian
    Qi, Jinyi
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : 541 - 559
  • [36] Compensation of patient motion in PET using a rotator and list-mode reconstruction
    Chen, Yu
    Glick, J.
    King, Michael A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2692 - 2696
  • [37] 4D PET with the quad-HIDAC: Development of dynamic list-mode EM image reconstruction
    Walledge, RJ
    Reader, AJ
    Aboagye, EO
    Spinks, TJ
    Honer, M
    Missimer, J
    Jeavons, AP
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1716 - 1720
  • [38] Maximum-likelihood image reconstruction from list-mode data.
    Parra, LC
    Barrett, HH
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 486 - 486
  • [39] Four-dimensional PET image reconstruction with respiratory and cardiac motion compensation from list-mode data
    Chen, Si
    Bravo, Paco
    Lodge, Martin
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [40] Maximum Likelihood Event Estimation and List-mode Image Reconstruction on GPU Hardware
    Caucci, Luca
    Furenlid, Lars R.
    Barrett, Harrison H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4072 - 4076