Volumetric absorptive microsampling-LC-MS/MS assays for quantitation of giredestrant in dried human whole blood

被引:2
|
作者
Johnson, Ryan [1 ]
Rehmani, Imran [2 ]
Leahy, Mark [2 ]
Walker, Abigail [2 ]
Liang, Xiaorong [1 ]
Dean, Brian [1 ]
Wang, Jianshuang [1 ]
机构
[1] Genentech Inc, Dept Drug Metab & Pharmacokinet, San Francisco, CA 94080 USA
[2] Labcorp Early Drug Dev, Dept Bioanalyt Chem, Madison, WI USA
关键词
anticoagulant; hematocrit; LC-MS/MS; microsampling; Mitra; Tasso-M20; validation; VAMS; whole blood; QUANTIFICATION; HEMATOCRIT; SPOTS; VALIDATION;
D O I
10.4155/bio-2022-0189
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Volumetric absorption microsampling devices offer minimally invasive and user-friendly collection of capillary blood in volumes as low as 10 mu l. Herein we describe the assay validation for determination of the selective estrogen receptor degrader giredestrant (GDC-9545) in dried human whole blood collected using the Mitra((R)) and Tasso-M20 devices. Both LC-MS/MS assays met validation acceptance criteria for the linear range 1-1000 ng/ml giredestrant. Mitra and Tasso-M20 samples were stable for 84 and 28 days at ambient conditions, respectively, and for 7-9 days at 40 and -70 degrees C. Blood hematocrit, hyperlipidemia and anticoagulant did not impact quantitation of giredestrant. These validated assays are suitable for the determination of giredestrant in dried blood samples collected using Mitra and Tasso-M20 microsampling devices. This methodology publication explores the bioanalytical considerations of the assays used to measure giredestrant in human whole blood samples collected using the Mitra and Tasso-M20 volumetric absorption microsampling devices. #Microsampling
引用
收藏
页码:1377 / 1389
页数:14
相关论文
共 50 条
  • [41] Quantitation of meropenem in dried blood spots using microfluidic-based volumetric sampling coupled with LC-MS/MS bioanalysis in preterm neonates
    Hu, Linlin
    Zhang, Jinlu
    He, Jie
    Zhang, Siliang
    Liu, Dongxue
    Shao, Hua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1217
  • [42] Study of dried blood spots technique for the determination of dextromethorphan and its metabolite dextrorphan in human whole blood by LC-MS/MS
    Liang, Xiaorong
    Li, Yinghe
    Barfield, Matthew
    Ji, Qin C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (8-9): : 799 - 806
  • [43] Detection of ethyl glucuronide in dried human blood using LC-MS/MS
    Kaufmann, Eckhard
    Alt, Andreas
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2008, 122 (03) : 245 - 249
  • [44] Detection of ethyl glucuronide in dried human blood using LC-MS/MS
    Eckhard Kaufmann
    Andreas Alt
    International Journal of Legal Medicine, 2008, 122 : 245 - 249
  • [45] LC-APCI-MS-MS for the determination of celastrol in human whole blood
    Xu, Qing
    Huang, Mei
    Jin, Micong
    Ren, Qilong
    CHROMATOGRAPHIA, 2007, 66 (9-10) : 735 - 739
  • [46] Volumetric absorptive microsampling (VAMS) as an alternative to conventional dried blood spots in the quantification of miltefosine in dried blood samples
    Kip, A. E.
    Kiers, K. C.
    Rosing, H.
    Schellens, J. H. M.
    Beijnen, J. H.
    Dorlo, T. P. C.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 135 : 160 - 166
  • [47] QUANTITATION OF THC AND METABOLITES IN WHOLE BLOOD BY LC-MS/MS FOR PER SE LAW TESTING
    Taylor, Adrian
    Tran, Diana
    He, Xiang
    Blethen, Tracy
    Kopp, Kevin
    Kopp, Matt
    Wang, Alexandre
    Liu, Hua-Fen
    FORENSIC SCIENCE INTERNATIONAL, 2017, 277 : 244 - 244
  • [48] An improved LC-MS/MS method for quantitation of indapamide in whole blood: application for a bioequivalence study
    Pinto, Guilherme Araujo
    Fercondini Pastre, Katia Isabel
    Bellorio, Karini Bruno
    Teixeira, Leonardo de Souza
    de Souza, Weidson Carlo
    de Abreu, Fernanda Crunivel
    de Santana e Silva Cardoso, Fabiana Fernandes
    Pianetti, Gerson Antonio
    Cesar, Isabela Costa
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (09) : 1212 - 1218
  • [49] Development and validation of a LC-MS/MS method for the quantitation of lumefantrine in mouse whole blood and plasma
    Govender, Katya
    Gibhard, Liezl
    Du Plessis, Lissinda
    Wiesner, Lubbe
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 985 : 6 - 13
  • [50] Quantitation of drugs using for treatment of essential hypertension in dried blood spots by LC-MS/MS and correlation with dried serum spots
    Chernonosov, A.
    Kasakin, M.
    Koval, V.
    FEBS OPEN BIO, 2018, 8 : 467 - 468