Volumetric absorptive microsampling-LC-MS/MS assays for quantitation of giredestrant in dried human whole blood

被引:2
|
作者
Johnson, Ryan [1 ]
Rehmani, Imran [2 ]
Leahy, Mark [2 ]
Walker, Abigail [2 ]
Liang, Xiaorong [1 ]
Dean, Brian [1 ]
Wang, Jianshuang [1 ]
机构
[1] Genentech Inc, Dept Drug Metab & Pharmacokinet, San Francisco, CA 94080 USA
[2] Labcorp Early Drug Dev, Dept Bioanalyt Chem, Madison, WI USA
关键词
anticoagulant; hematocrit; LC-MS/MS; microsampling; Mitra; Tasso-M20; validation; VAMS; whole blood; QUANTIFICATION; HEMATOCRIT; SPOTS; VALIDATION;
D O I
10.4155/bio-2022-0189
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Volumetric absorption microsampling devices offer minimally invasive and user-friendly collection of capillary blood in volumes as low as 10 mu l. Herein we describe the assay validation for determination of the selective estrogen receptor degrader giredestrant (GDC-9545) in dried human whole blood collected using the Mitra((R)) and Tasso-M20 devices. Both LC-MS/MS assays met validation acceptance criteria for the linear range 1-1000 ng/ml giredestrant. Mitra and Tasso-M20 samples were stable for 84 and 28 days at ambient conditions, respectively, and for 7-9 days at 40 and -70 degrees C. Blood hematocrit, hyperlipidemia and anticoagulant did not impact quantitation of giredestrant. These validated assays are suitable for the determination of giredestrant in dried blood samples collected using Mitra and Tasso-M20 microsampling devices. This methodology publication explores the bioanalytical considerations of the assays used to measure giredestrant in human whole blood samples collected using the Mitra and Tasso-M20 volumetric absorption microsampling devices. #Microsampling
引用
收藏
页码:1377 / 1389
页数:14
相关论文
共 50 条
  • [21] Quantitation of total folate in whole blood using LC-MS/MS
    Owens, JE
    Holstege, DM
    Clifford, AJ
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (19) : 7390 - 7394
  • [22] Development and validation of volumetric absorptive microsampling coupled with UHPLC-MS/MS for the analysis of gamma-hydroxybutyric acid in human blood
    Mohamed, Susan
    Riva, Roberto
    Moresco, Monica
    Plazzi, Giuseppe
    Contin, Manuela
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (03)
  • [23] LC-MS/MS measurement of endogenous steroid hormones and phase II metabolites in blood volumetric absorptive microsampling (VAMS) for doping control purposes
    Ponzetto, Federico
    Parasiliti-Caprino, Mirko
    Leoni, Laura
    Marinelli, Lorenzo
    Nonnato, Antonello
    Nicoli, Raul
    Kuuranne, Tiia
    Ghigo, Ezio
    Mengozzi, Giulio
    Settanni, Fabio
    CLINICA CHIMICA ACTA, 2024, 557
  • [24] Quantitation of tenofovir and emtricitabine in dried blood spots (DBS) with LC-MS/MS
    Zheng, Jia-Hua
    Guida, Louis A.
    Rower, Caitlin
    Castillo-Mancilla, Jose
    Meditz, Amie
    Klein, Brandon
    Kerr, Becky Jo
    Langness, Jacob
    Bushman, Lane
    Kiser, Jennifer
    Anderson, Peter L.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 : 144 - 151
  • [25] Quantitative bioanalytical validation of fosfomycin in human whole blood with volumetric absorptive microsampling
    Parker, Suzanne L.
    Roberts, Jason A.
    Lipman, Jeffrey
    Wallis, Steven C.
    BIOANALYSIS, 2015, 7 (19) : 2585 - 2595
  • [26] Validation and clinical application of a LC-MS/MS method for simultaneous quantification of 4 immunosuppressants using volumetric absorptive microsampling
    Zahr, N.
    Tissot, N.
    Barrou, B.
    Arzouk, N.
    Nguyen, L.
    Calmus, Y.
    Conti, F.
    Funck-Brentano, C.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2021, 35 : 103 - 104
  • [27] Determination of paracetamol and its metabolites via LC-MS/MS in dried blood volumetric absorptive microsamples: A tool for pharmacokinetic studies
    Delahaye, Lisa
    De Baerdemaeker, Luc
    Stove, Christophe P.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 206
  • [28] Patient-Centric Assessment of Thiamine Status in Dried Blood Volumetric Absorptive Microsamples Using LC-MS/MS Analysis
    Verstraete, Jana
    Stove, Christophe
    ANALYTICAL CHEMISTRY, 2021, 93 (04) : 2660 - 2668
  • [29] Quantitation of methotrexate polyglutamates in human whole blood, erythrocytes and leukocytes collected via venepuncture and volumetric absorptive micro-sampling: a green LC-MS/MS-based method
    Daraghmeh, Dala N.
    Moghaddami, Mahin
    Bobrovskaya, Larisa
    Proudman, Susanna M.
    Wiese, Michael D.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (20) : 6029 - 6046
  • [30] A Volumetric Absorptive Microsampling UPLC-MS/MS Method for Simultaneous Quantification of Tacrolimus, Mycophenolic Acid and Creatinine in Whole Blood of Renal Transplant Recipients
    Wang, Xueqiao
    Dai, Xinhua
    Wan, Shiqi
    Fan, Yu
    Wu, Lijuan
    Xu, Huan
    Yan, Lin
    Gong, Xingxin
    Li, Yamei
    Luo, Yao
    Bai, Yangjuan
    Li, Yi
    PHARMACEUTICS, 2022, 14 (12)