T2-weighted MRI and reduced-FOV diffusion-weighted imaging of the human pancreas at 5 T: A comparison study with 3 T

被引:2
|
作者
Zheng, Liyun [1 ,2 ,3 ]
Yang, Chun [1 ,2 ]
Liang, Liang [1 ,2 ]
Rao, Shengxiang [1 ,2 ]
Dai, Yongming [4 ]
Zeng, Mengsu [1 ,2 ]
机构
[1] Shanghai Inst Med Imaging, Shanghai, Peoples R China
[2] Fudan Univ, Zhongshan Hosp, Dept Radiol, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[3] Shenzhen United Imaging Res Inst Innovat Med Equi, Shenzhen, Peoples R China
[4] United Imaging Healthcare, Cent Res Inst, MR Collaborat, 2258 Chengbei Rd, Shanghai 201807, Peoples R China
基金
中国国家自然科学基金;
关键词
diffusion-weighted imaging; high-field MRI; pancreatic imaging; reduced field-of-view; 5; 0; T; MAGNETIC-RESONANCE; LESION DETECTION; BREATH-HOLD; NORMAL HEAD; 3.0; TESLA; LIVER; CANCER; BODY; DWI; REPRODUCIBILITY;
D O I
10.1002/mp.15970
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to explore the feasibility of pancreatic imaging at 5 T and evaluate the practical improvement of T2-weighted MRI and diffusion-weighted imaging (DWI) at 5 T as compared with 3 T. Methods Eighteen healthy subjects were recruited for this pilot study. MRI examinations were performed using 3 and 5 T scanners. MRI sequences included T2-weighted fast spin-echo and DWI with reduced field-of-view. Subjective image analysis using a four-point Likert scale was performed by two experienced radiologists. The SNR, contrast ratio, and apparent diffusion coefficient (ADC) were measured in the pancreatic head, body, and tail. The coefficient of variation (CV) of the ADC was calculated. A series of paired Wilcoxon tests were used to compare the subjective image quality, mean ADC value, and CV of ADC between the 3 and 5 T measurements. p For T2-weighted images, there were no significant differences in image quality ratings between 3 and 5 T. On DWI images (b = 0 and 800 s/mm(2)), the image quality ratings were significantly higher at 5 T than at 3 T. The SNRs of both T2-weighted and DWI images were significantly higher at 5 T. There was no significant difference in the mean ADC values and CV of ADC between 3 and 5 T. Conclusion This initial study proved that 5 T MRI can be used to acquire pancreatic images with higher SNR and sufficient image quality compared to 3 T MRI.
引用
收藏
页码:344 / 353
页数:10
相关论文
共 50 条
  • [21] COMPARISON OF DIFFUSION-WEIGHTED AND T2-WEIGHTED MRI FOR THE EARLY DETECTION OF CEREBRAL-ISCHEMIA AND REPERFUSION IN RATS
    MINTOROVITCH, J
    MOSELEY, ME
    CHILEUITT, L
    SHIMIZU, H
    COHEN, Y
    WEINSTEIN, PR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) : 39 - 50
  • [22] Pulmonary Nodule and Mass: Superiority of MRI of Diffusion-Weighted Imaging and T2-Weighted Imaging to FDG-PET/CT
    Usuda, Katsuo
    Ishikawa, Masahito
    Iwai, Shun
    Yamagata, Aika
    Iijima, Yoshihito
    Motono, Nozomu
    Matoba, Munetaka
    Doai, Mariko
    Hirata, Keiya
    Uramoto, Hidetaka
    [J]. CANCERS, 2021, 13 (20)
  • [23] A Brief Review of the Combined Use of T2-Weighted MRI and Diffusion-Weighted Imaging for Prostate Cancer Diagnosis Reply
    Wu, Lian-Ming
    Xu, Jian-Rong
    Hu, Jiani
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (02) : W220 - W221
  • [24] Correction: Diffusion-weighted imaging complements T2-weighted MRI for tumour response assessment in squamous anal carcinoma
    Davide Prezzi
    Keerthini Muthuswamy
    Ashik Amlani
    Kasia Owczarczyk
    Ahmed Elowaidy
    Tina Mistry
    Paul Bassett
    Vicky Goh
    [J]. European Radiology, 2024, 34 : 1408 - 1408
  • [25] EARLY DETECTION OF REGIONAL CEREBRAL-ISCHEMIA IN CATS - COMPARISON OF DIFFUSION-WEIGHTED AND T2-WEIGHTED MRI AND SPECTROSCOPY
    MOSELEY, ME
    COHEN, Y
    MINTOROVITCH, J
    CHILEUITT, L
    SHIMIZU, H
    KUCHARCZYK, J
    WENDLAND, MF
    WEINSTEIN, PR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 330 - 346
  • [26] Histological grade of differentiation of hepatocellular carcinoma: Comparison of the efficacy of diffusion-weighted MRI with T2-weighted imaging and angiography-assisted CT
    Saito, Kazuhiro
    Moriyasu, Fuminori
    Sugimoto, Katsutoshi
    Nishio, Ryota
    Saguchi, Toru
    Akata, Soichi
    Tokuuye, Koichi
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (03) : 261 - 269
  • [27] Three-dimensional isotropic T2-weighted cervical MRI at 3 T: Comparison with two-dimensional T2-weighted sequences
    Kwon, J. W.
    Yoon, Y. C.
    Choi, S. -H.
    [J]. CLINICAL RADIOLOGY, 2012, 67 (02) : 106 - 113
  • [28] Combined use of T2-weighted and diffusion-weighted 3-T MR imaging for differentiating uterine sarcomas from benign leiomyomas
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    Awai, Kazuo
    Nakaura, Takeshi
    Yanaga, Yumi
    Hirai, Toshinori
    Saito, Tetsuo
    Katabuchi, Hidetaka
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (11) : 2756 - 2764
  • [29] Combined use of T2-weighted and diffusion-weighted 3-T MR imaging for differentiating uterine sarcomas from benign leiomyomas
    Tomohiro Namimoto
    Yasuyuki Yamashita
    Kazuo Awai
    Takeshi Nakaura
    Yumi Yanaga
    Toshinori Hirai
    Tetsuo Saito
    Hidetaka Katabuchi
    [J]. European Radiology, 2009, 19 : 2756 - 2764
  • [30] Extracapsular Extension in Prostate Cancer: Added Value of Diffusion-Weighted MRI in Patients With Equivocal Findings on T2-Weighted Imaging
    Woo, Sungmin
    Cho, Jeong Yeon
    Kim, Sang Youn
    Kim, Seung Hyup
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (02) : W168 - W175