T2-weighted MRI and reduced-FOV diffusion-weighted imaging of the human pancreas at 5 T: A comparison study with 3 T

被引:2
|
作者
Zheng, Liyun [1 ,2 ,3 ]
Yang, Chun [1 ,2 ]
Liang, Liang [1 ,2 ]
Rao, Shengxiang [1 ,2 ]
Dai, Yongming [4 ]
Zeng, Mengsu [1 ,2 ]
机构
[1] Shanghai Inst Med Imaging, Shanghai, Peoples R China
[2] Fudan Univ, Zhongshan Hosp, Dept Radiol, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[3] Shenzhen United Imaging Res Inst Innovat Med Equi, Shenzhen, Peoples R China
[4] United Imaging Healthcare, Cent Res Inst, MR Collaborat, 2258 Chengbei Rd, Shanghai 201807, Peoples R China
基金
中国国家自然科学基金;
关键词
diffusion-weighted imaging; high-field MRI; pancreatic imaging; reduced field-of-view; 5; 0; T; MAGNETIC-RESONANCE; LESION DETECTION; BREATH-HOLD; NORMAL HEAD; 3.0; TESLA; LIVER; CANCER; BODY; DWI; REPRODUCIBILITY;
D O I
10.1002/mp.15970
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to explore the feasibility of pancreatic imaging at 5 T and evaluate the practical improvement of T2-weighted MRI and diffusion-weighted imaging (DWI) at 5 T as compared with 3 T. Methods Eighteen healthy subjects were recruited for this pilot study. MRI examinations were performed using 3 and 5 T scanners. MRI sequences included T2-weighted fast spin-echo and DWI with reduced field-of-view. Subjective image analysis using a four-point Likert scale was performed by two experienced radiologists. The SNR, contrast ratio, and apparent diffusion coefficient (ADC) were measured in the pancreatic head, body, and tail. The coefficient of variation (CV) of the ADC was calculated. A series of paired Wilcoxon tests were used to compare the subjective image quality, mean ADC value, and CV of ADC between the 3 and 5 T measurements. p For T2-weighted images, there were no significant differences in image quality ratings between 3 and 5 T. On DWI images (b = 0 and 800 s/mm(2)), the image quality ratings were significantly higher at 5 T than at 3 T. The SNRs of both T2-weighted and DWI images were significantly higher at 5 T. There was no significant difference in the mean ADC values and CV of ADC between 3 and 5 T. Conclusion This initial study proved that 5 T MRI can be used to acquire pancreatic images with higher SNR and sufficient image quality compared to 3 T MRI.
引用
收藏
页码:344 / 353
页数:10
相关论文
共 50 条
  • [1] Prostate cancer detection with 3-T MRI: Comparison of diffusion-weighted and T2-weighted imaging
    Miao, Huadong
    Fukatsu, Hiroshi
    Ishigaki, Takeo
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2007, 61 (02) : 297 - 302
  • [2] Prostate Cancer Detection With 3 T MRI: Comparison of Diffusion-Weighted Imaging and Dynamic Contrast-Enhanced MRI in Combination With T2-Weighted Imaging
    Kitajima, Kazuhiro
    Kaji, Yasushi
    Fukabori, Yoshitatsu
    Yoshida, Ken-ichiro
    Suganuma, Narufumi
    Sugimura, Kazuro
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 625 - 631
  • [3] Hadamard Slice Encoding for Reduced-FOV Diffusion-Weighted Imaging
    Saritas, Emine Ulku
    Lee, Daeho
    Cukur, Tolga
    Shankaranarayanan, Ajit
    Nishimura, Dwight G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (05) : 1277 - 1290
  • [4] T staging of rectal cancer: Accuracy of diffusion-weighted imaging compared with T2-weighted imaging on 3.0 tesla MRI
    Feng, Qi
    Yan, Yun Qi
    Zhu, Jiong
    Xu, Jian Rong
    [J]. JOURNAL OF DIGESTIVE DISEASES, 2014, 15 (04) : 188 - 194
  • [5] Combined T2-weighted and diffusion-weighted MRI for localization of prostate cancer
    Haider, Masoom A.
    van der Kwast, Theodorus H.
    Tanguay, Jeff
    Evans, Andrew J.
    Hashmi, Ali-Tahir
    Lockwood, Gina
    Trachtenberg, John
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) : 323 - 328
  • [6] Comparison of Diffusion-Weighted with T2-weighted Imaging for Detection of Small Hepatocellular Carcinoma in Cirrhosis: Preliminary Quantitative Study at 3-T
    Wang, Hua
    Wang, Xiao-Ying
    Jiang, Xue-Xiang
    Ye, Zhao-Xiang
    [J]. ACADEMIC RADIOLOGY, 2010, 17 (02) : 239 - 243
  • [7] Comparison of diffusion-weighted with T2-weighted imaging for detection of edema in acute myocardial infarction
    Kociemba, Anna
    Pyda, Malgorzta
    Katulska, Katarzyna
    Lanocha, Magdalena
    Siniawski, Andrzej
    Janus, Magdalena
    Grajek, Stefan
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [8] Comparison of diffusion-weighted with T2-weighted imaging for detection of edema in acute myocardial infarction
    Anna Kociemba
    Małgorzta Pyda
    Katarzyna Katulska
    Magdalena Łanocha
    Andrzej Siniawski
    Magdalena Janus
    Stefan Grajek
    [J]. Journal of Cardiovascular Magnetic Resonance, 15
  • [9] Comparison of T2-weighted and diffusion-weighted imaging for the diagnosis of placenta accreta spectrum abnormality
    Prakash, Adity
    Kumar, Ishan
    Verma, Ashish
    Shukla, Ram C.
    [J]. ACTA RADIOLOGICA, 2023, 64 (04) : 1694 - 1701
  • [10] T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
    Kang, Kyung A.
    Kim, Young Kon
    Kim, EunJu
    Jeong, Woo Kyoung
    Choi, Dongil
    Lee, Won Jae
    Jung, Sin-Ho
    Baek, Sun-Young
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (05) : 1038 - 1046