Patient- Specific Drill Guide Template for Pedicle Screw Insertion into the Atlantoaxial Cervical Spine Using Stereolithographic Modeling: An In Vitro Study

被引:2
|
作者
Bundoc, Rafael Cruz [1 ]
Obenieta, Harjoland Lim [1 ]
Dizon, Dave Anthony Gatchalian [1 ]
机构
[1] Univ Philippines, Dept Orthopaed, Sect Spine Surg, Philippine Gen Hosp, Manila, Philippines
关键词
Axial cervical spine; Cervical pedicle screw fixation; Three-dimensional printing; Stereolithography; Patient-specific surgical template; FIXATION; PLACEMENT; ACCURACY;
D O I
10.31616/asj.2021.0362
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Cadaveric study. Purpose: This study aimed to assess the accuracy and feasibility of cervical pedicle screw (CPS) insertion into the atlantoaxial cervical spine using a patient-specific drill guide template constructed from a stereolithographic model. Overview of Literature: CPS fixation is a widely accepted procedure for posterior cervical fixation because of its biomechanical advantages, particularly in the subaxial cervical region. The extremely narrow corridors of the atlantoaxial spine make CPS insertion more difficult, requiring the development of new tools to ensure accurate placement. Methods: Fifteen atlantoaxial cervical vertebra specimens from 15 cadavers were scanned into thin slices using computed tomography. Images of the cadaver spine were digitally processed and rendered stl files so that they could be printed to scale as three-dimensional (3D) plastic models. Manually molded dental acrylic drill guide templates with pins inserted in the pedicles of the plastic cervical models were placed over the 3D printed models. The drill guide templates were used for precise placement of the drill holes in the pedicles of cadaveric specimens for pedicle screw fixation. The accuracy of screw placement was evaluated by an independent evaluator. Results: A total of 60 pedicles (combined C1 and C2) from 15 cadaveric axial cervical vertebrae were evaluated. The total acceptable accuracy for pedicle screw insertion in the atlantoaxial cervical vertebrae is 95%. An accuracy rate of 100% was achieved for C1 while an acceptable accuracy rate of 90% was achieved for C2. Conclusions: The use of a patient-specific drill guide constructed using stereolithography improved the accuracy of CPS placement in a cadaveric model.
引用
下载
收藏
页码:8 / 16
页数:9
相关论文
共 50 条
  • [21] Accuracy of pedicle screw insertion in the cervical spine for internal fixation using frameless stereotactic guidance
    Rath, Stefan A.
    Moszko, Slawomir
    Schaeffner, Petra M.
    Cantone, Giuseppe
    Braun, Veit
    Richter, Hans-Peter
    Antoniadis, Gregor
    JOURNAL OF NEUROSURGERY-SPINE, 2008, 8 (03) : 237 - 245
  • [22] Operative Effect Comparison of Flexible Drill Guiding vs. Traditional Drill Guiding Template for Lower Cervical Pedicle Screw Insertion: A Retrospective Analysis
    Wu, Chao
    Deng, Jiayan
    Hu, Haigang
    Shen, Danwei
    Qin, Binwei
    Wang, Xiangyu
    Gao, Tao
    Xu, Lian
    ORTHOPAEDIC SURGERY, 2023, 15 (07) : 1823 - 1830
  • [23] Assessing the Accuracy and Safety Thresholds of Patient-Specific Screw Guide Template System in Cervical and Thoracic Spine Surgeries Using DAST Measurements
    Kaneyama, Shuichi
    Sugawara, Taku
    SPINE SURGERY AND RELATED RESEARCH, 2024, 8 (03): : 297 - 305
  • [24] Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion An Analysis of 76 Cervical and Thoracic Screw Trajectories
    Pijpker, Peter A. J.
    Kraeima, Joep
    Witjes, Max J. H.
    Oterdoom, D. L. Marinus
    Vergeer, Rob A.
    Coppes, Maarten H.
    Groen, Rob J. M.
    Kuijlen, Jos M. A.
    SPINE, 2021, 46 (03) : 160 - 168
  • [25] A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study
    Lu, Sheng
    Xu, Yong Q.
    Zhang, Yuan Z.
    Li, Yan B.
    Xie, L. E.
    Shi, Ji H.
    Guo, Hai
    Chen, Guo P.
    Chen, Yu B.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (02): : 184 - 191
  • [26] Application of a novel 3D drill template for cervical pedicle screw tunnel design: a cadaveric study
    Zhengxi Yu
    Guodong Zhang
    Xuanhuang Chen
    Xu Chen
    Changfu Wu
    Yijun Lin
    Wenhua Huang
    Haibin Lin
    European Spine Journal, 2017, 26 : 2348 - 2356
  • [27] Application of a novel 3D drill template for cervical pedicle screw tunnel design: a cadaveric study
    Yu, Zhengxi
    Zhang, Guodong
    Chen, Xuanhuang
    Chen, Xu
    Wu, Changfu
    Lin, Yijun
    Huang, Wenhua
    Lin, Haibin
    EUROPEAN SPINE JOURNAL, 2017, 26 (09) : 2348 - 2356
  • [28] A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine
    Merc, Matjaz
    Drstvensek, Igor
    Vogrin, Matjaz
    Brajlih, Tomaz
    Recnik, Gregor
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (07) : 893 - 899
  • [29] In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III)
    Heiko Koller
    Wolfgang Hitzl
    Frank Acosta
    Mark Tauber
    Juliane Zenner
    Herbert Resch
    Yasutsugu Yukawa
    Oliver Meier
    Rene Schmidt
    Michael Mayer
    European Spine Journal, 2009, 18 : 1300 - 1313
  • [30] In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III)
    Koller, Heiko
    Hitzl, Wolfgang
    Acosta, Frank
    Tauber, Mark
    Zenner, Juliane
    Resch, Herbert
    Yukawa, Yasutsugu
    Meier, Oliver
    Schmidt, Rene
    Mayer, Michael
    EUROPEAN SPINE JOURNAL, 2009, 18 (09) : 1300 - 1313