The accuracy of dynamic computer assisted implant surgery in fully edentulous jaws: A retrospective case series

被引:6
|
作者
Wang, Jiayi [1 ,2 ,3 ,4 ,5 ,6 ,7 ]
Ge, Yanjun [2 ,3 ,4 ,5 ,6 ,7 ,8 ,10 ]
Muhlemann, Sven [9 ]
Pan, Shaoxia [2 ,3 ,4 ,5 ,6 ,7 ,8 ,10 ]
Jung, Ronald E. [9 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Orthodont, Beijing, Peoples R China
[2] Natl Ctr Stomatol, Beijing, Peoples R China
[3] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[4] Natl Engn Res Ctr Oral Biomat & Digital Med Device, Beijing, Peoples R China
[5] Beijing Key Lab Digital Stomatol, Beijing, Peoples R China
[6] Res Ctr Engn & Technol Computerized Dent Minist Hl, Beijing, Peoples R China
[7] NMPA Key Lab Dent Mat, Beijing, Peoples R China
[8] Peking Univ, Sch & Hosp Stomatol, Dept Prosthodont, Beijing, Peoples R China
[9] Univ Zurich, Ctr Dent Med, Clin Reconstruct Dent, Zurich, Switzerland
[10] Peking Univ, Sch & Hosp Stomatol, Dept Prosthodont, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
基金
北京市自然科学基金;
关键词
accuracy; CAIS; dynamic navigation; edentulous; implant; PLACEMENT;
D O I
10.1111/clr.14168
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the accuracy of implant placement using a dynamic navigation system in fully edentulous jaws and to analyze the influence of implant distribution on implant position accuracy. Materials and Methods: Edentulous patients who received implant placement using a dynamic navigation system were included. Four to six mini screws were placed in the edentulous jaw under local anesthesia as fiducial markers. Then patients received CBCT scans. Virtual implant positions were designed in the planning software based on CBCT data. Under local anesthesia, implants were inserted under the guidance of the dynamic navigation system. CBCTs were taken following implant placement. The deviation between the actual and planned implant positions was measured by comparing the pre- and postsurgery CBCT. Results: A total of 13 edentulous patients with 13 edentulous maxillae and 7 edentulous mandibles were included, and 108 implants were placed. The average linear deviations at the implant entry point and apex were 1.08 +/- 0.52 mm and 1.15 +/- 0.60 mm, respectively. The average angular deviation was 2.85 +/- 1.20 degrees. No significant difference was detected in linear and angular deviations between the maxillary and mandibular implants, neither between the anterior and posterior implants. Conclusions: The dynamic navigation system provides high accuracy for implant placement in fully edentulous jaws, while the distribution of the implants showed little impact on implant position accuracy.
引用
收藏
页码:1278 / 1288
页数:11
相关论文
共 50 条
  • [31] Accuracy of implant surgical guides fabricated using computer numerical control milling for edentulous jaws: a pilot clinical trial
    Jinyou Chai
    Xiaoqian Liu
    Ramona Schweyen
    Jürgen Setz
    Shaoxia Pan
    Jianzhang Liu
    Yongsheng Zhou
    BMC Oral Health, 20
  • [32] Accuracy of implant surgical guides fabricated using computer numerical control milling for edentulous jaws: a pilot clinical trial
    Chai, Jinyou
    Liu, Xiaoqian
    Schweyen, Ramona
    Setz, Juergen
    Pan, Shaoxia
    Liu, Jianzhang
    Zhou, Yongsheng
    BMC ORAL HEALTH, 2020, 20 (01)
  • [33] Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial
    Edelmann, Cornelia
    Wetzel, Martin
    Knipper, Anne
    Luthardt, Ralph G.
    Schnutenhaus, Sigmar
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [34] Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study
    Otaghsara, Seyedeh Sahar Taheri
    Joda, Tim
    Thieringer, Florian Markus
    JOURNAL OF DENTISTRY, 2023, 132
  • [35] Accuracy of computer-guided implant surgery in partially edentulous patients: a prospective observational study
    Chrabieh, Emile
    Hanna, Christine
    Mrad, Stephanie
    Rameh, Stephanie
    Bassil, Joseph
    Zaarour, Joseph
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [36] Accuracy of immediate anterior implantation using static and robotic computer-assisted implant surgery: A retrospective study
    Li, Jun
    Dai, Meng
    Wang, Siwei
    Zhang, Xitao
    Fan, Qin
    Chen, Lin
    JOURNAL OF DENTISTRY, 2024, 148
  • [37] In vitro and in vivo accuracy of autonomous robotic vs. fully guided static computer-assisted implant surgery
    He, Jin
    Zhang, Qinmeng
    Wang, Xueting
    Fu, Mengdie
    Zhang, Hui
    Song, Luyao
    Pu, Rui
    Jiang, Zhiwei
    Yang, Guoli
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 385 - 401
  • [38] A comparative retrospective study of different surgical guide designs for static computer-assisted implant surgery in posterior single edentulous sites
    De Souza, Andre Barbisan
    Kang, Michael
    Negreiros, William Matthew
    El-Rafie, Khaled
    Finkelman, Matthew
    Papaspyridakos, Panos
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (01) : 45 - 52
  • [39] Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients: A Case Report
    Oh, Ji-Hyeon
    An, Xueyin
    Jeong, Seung-Mi
    Choi, Byung-Ho
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (12) : 2541 - 2549
  • [40] Digital workflow for prosthetically driven implant navigation surgery in a fully edentulous patient: a case report
    Wang, Miaozhen
    Eitan, Mijiritsky
    Zhan, Yalin
    Shen, Huidan
    Liu, Feng
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2021, 24 (03) : 303 - 315