Quantitative 31P magnetic resonance imaging on pathologic rat bones by ZTE at 7T

被引:2
|
作者
Kassey, Victor B. [1 ,2 ,3 ,6 ]
Walle, Matthias [1 ]
Egan, Jonathan [1 ]
Yeritsyan, Diana [1 ]
Beeram, Indeevar [1 ]
Wu, Yaotang [2 ,3 ,6 ]
Snyder, Brian D. [1 ,2 ,6 ]
Rodriguez, Edward K. [1 ,6 ]
Ackerman, Jerome L. [3 ,4 ,6 ]
Nazarian, Ara [1 ,5 ,6 ,7 ]
机构
[1] Beth Israel Deaconess Med Ctr, Carl J Shapiro Dept Orthopaed Surg, Musculoskeletal Translat Innovat Initiat, Boston, MA 02215 USA
[2] Childrens Hosp, Dept Orthopaed Surg, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA 02129 USA
[4] Harvard MIT Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[5] Yerevan State Med Univ, Dept Orthopaed Surg, Yerevan, Armenia
[6] Harvard Med Sch, Boston, MA 02115 USA
[7] Beth Israel Deaconess Med Ctr, Musculoskeletal Translat Innovat Initiat, 330 Brookline Ave,RN123, Boston, MA 02215 USA
基金
美国国家卫生研究院;
关键词
Bone mineral density; Solid state MR imaging; Osteoporosis; Renal osteodystrophy; Rat; ULTRASHORT ECHO TIME; SOLID-STATE P-31; PROJECTION MRI WASPI; VITAMIN-D DEFICIENCY; IMAGED IN-VIVO; CORTICAL BONE; WATER; OSTEOPOROSIS; OSTEOMALACIA; DENSITY;
D O I
10.1016/j.bone.2023.116996
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Osteoporosis is characterized by low bone mineral density (BMD), which predisposes individuals to frequent fragility fractures. Quantitative BMD measurements can potentially help distinguish bone pathologies and allow clinicians to provide diseaserelieving therapies. Our group has developed non-invasive and non ionizing magnetic resonance imaging (MRI) techniques to measure bone mineral density quantitatively. Dual energy X-ray Absorptiometry (DXA) is a clinically approved non-invasive modality to diagnose osteoporosis but has associated disadvantages and limitations. Purpose: Evaluate the clinical feasibility of phosphorus (31P) MRI as a non-invasive and non-ionizing medical diagnostic tool to compute bone mineral density to help differentiate between different metabolic bone diseases. Materials and methods: Fifteen ex-vivo rat bones in three groups [control, ovariectomized (osteoporosis), and vitamin-D deficient (osteomalacia hypo-mineralized) were scanned to compute BMD. A double-tuned (1H/31P) transmit-receive single RF coil was custom-designed and in-house-built with a better filling factor and strong radiofrequency (B1) field to acquire solid-state 31P MR images from rat femurs with an optimum signal-to-noise ratio (SNR). Micro-computed tomography (mu CT) and gold-standard gravimetric analyses were performed to compare and validate MRI-derived bone mineral densities. Results: Three-dimensional 31P MR images of rat bones were obtained with a zero-echo-time (ZTE) sequence with 468 mu m spatial resolution and 12-17 SNR on a Bruker 7 T Biospec having multinuclear capability. BMD was measured quantitatively on cortical and trabecular bones with a known standard reference. A strong positive correlation (R = 0.99) and a slope close to 1 in phantom measurements indicate that the densities measured by 31P ZTE MRI are close to the physical densities in computing quantitative BMD. The 31P NMR properties (resonance linewidth of 4 kHz and T1 of 67 s) of ex-vivo rat bones were measured, and 31P ZTE imaging parameters were optimized. The BMD results obtained from MRI are in good agreement with mu CT and gravimetry results. Conclusion: Quantitative measurements of BMD on ex-vivo rat femurs were successfully conducted on a 7 T preclinical scanner. This study suggests that quantitative measurements of BMD are feasible on humans in clinical MRI with suitable hardware, RF coils, and pulse sequences with optimized parameters within an acceptable scan time since human femurs are approximately ten times larger than rat femurs. As MRI provides quantitative in-vivo data, various systemic musculoskeletal conditions can be diagnosed potentially in humans.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] 31P magnetic resonance spectroscopy in fibromyalgic muscle
    Sprott, H
    Rzanny, R
    Reichenbach, JR
    Kaiser, WA
    Hein, G
    Stein, G
    RHEUMATOLOGY, 2000, 39 (10) : 1121 - 1125
  • [32] Magnetic resonance imaging of the cervical spinal cord in multiple sclerosis at 7T
    Dula, Adrienne N.
    Pawate, Siddharama
    Dortch, Richard D.
    Barry, Robert L.
    George-Durrett, Kristen M.
    Lyttle, Bailey D.
    Dethrage, Lindsey M.
    Gore, John C.
    Smith, Seth A.
    MULTIPLE SCLEROSIS JOURNAL, 2016, 22 (03) : 320 - 328
  • [33] Optimization of 31P magnetic resonance spectroscopy in vivo
    Manzhurtsev, A., V
    Akhadov, T. A.
    Semenova, N. A.
    VI INTERNATIONAL SCIENTIFIC SCHOOL-CONFERENCE OF YOUNG SCIENTISTS MODERN PROBLEMS OF PHYSICS AND TECHNOLOGIES, 2018, 945
  • [34] Total strength of the magnetic dipole resonance in 31P
    Kachan A.S.
    Kurguz I.V.
    Kovtunenko I.S.
    Mischenko V.M.
    Panin V.A.
    Bulletin of the Russian Academy of Sciences: Physics, 2009, 73 (11) : 1506 - 1510
  • [35] Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T
    Uwano, Ikuko
    Kudo, Kohsuke
    Yamashita, Fumio
    Goodwin, Jonathan
    Higuchi, Satomi
    Ito, Kenji
    Harada, Taisuke
    Ogawa, Akira
    Sasaki, Makoto
    MEDICAL PHYSICS, 2014, 41 (02) : 022302
  • [36] Rapid and recoverable in vivo magnetic resonance imaging of the adult zebrafish at 7T
    Merrifield, Gavin D.
    Mullin, James
    Gallagher, Lindsay
    Tucker, Carl
    Jansen, Maurits A.
    Denvir, Martin
    Holmes, William M.
    MAGNETIC RESONANCE IMAGING, 2017, 37 : 9 - 15
  • [37] Comparison of compressed sensing reconstruction algorithms for 31P magnetic resonance spectroscopic imaging
    Santos-Diaz, Alejandro
    Noseworthy, Michael D.
    MAGNETIC RESONANCE IMAGING, 2019, 59 : 88 - 96
  • [38] Unveiling a hidden 31P signal coresonating with extracellular inorganic phosphate by outer-volume-suppression and localized 31P MRS in the human brain at 7T
    Ren, Jimin
    Shang, Ty
    Sherry, A. Dean
    Malloy, Craig R.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) : 1289 - 1297
  • [39] Magnetic resonance imaging and 31P magnetic resonance spectroscopy investigations of muscle function disclose no abnormality in macrophagic myofasciitis
    Nicol, F
    Figarella-Branger, D
    Le Fur, Y
    Kaplanski, G
    Pelletier, J
    Harle, JR
    Cozzone, PJ
    Bendahan, D
    JOURNAL OF RHEUMATOLOGY, 2004, 31 (11) : 2313 - 2315
  • [40] Sharpness in motion corrected quantitative imaging at 7T
    Bazin, Pierre-Louis
    Nijsse, Hannah E.
    van der Zwaag, Wietske
    Gallichan, Daniel
    Alkemade, Anneke
    Vos, Frans M.
    Forstmann, Birte U.
    Caan, Matthan W. A.
    NEUROIMAGE, 2020, 222