Unveiling a hidden 31P signal coresonating with extracellular inorganic phosphate by outer-volume-suppression and localized 31P MRS in the human brain at 7T

被引:20
|
作者
Ren, Jimin [1 ,2 ]
Shang, Ty [3 ]
Sherry, A. Dean [1 ,2 ,4 ]
Malloy, Craig R. [1 ,2 ,5 ,6 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Adv Imaging Res Ctr, Dallas, TX 75390 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dept Radiol, Dallas, TX USA
[3] Univ Texas Southwestern Med Ctr Dallas, Dept Neurol & Neurotherapeut, Dallas, TX 75390 USA
[4] Univ Texas Dallas, Dept Chem, Richardson, TX 75083 USA
[5] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Dallas, TX USA
[6] VA North Texas Hlth Care Syst, Dallas, TX USA
基金
美国国家卫生研究院;
关键词
P-31; MRS; blood; brain; CSF; inorganic phosphate; pH; IN-VIVO; METABOLITE CONCENTRATIONS; RESONANCE-SPECTROSCOPY; ATP SYNTHESIS; PH; BLOOD; HYPOPHOSPHATEMIA; DYNAMICS; TISSUE;
D O I
10.1002/mrm.27121
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The study was undertaken to demonstrate that there is more than 1 component in the extracellular P-i P-31 signal (P-i(ex)) acquired from human head using nonlocalized P-31 MRS. Methods: Outer-volume-suppression (OVS) saturation and 1D/2D P-31 CSI were utilized to reveal the presence of an additional component in the P-i(ex) signal. Results: 67% of the head extracellular P-i signal was attenuated upon OVS saturation of the peripheral meningeal tissues, likely reflecting elimination of the P-i signal in the meningeal fluids (the blood and CSF). Localized 1D/2D CSI data provided further support for this assignment. Upon correction for the meningeal contribution, the extracellular P-i concentration was 0.51 +/- 0.07 mM, whereas the intracellular P-i was 0.85 +/- 0.10 mM. The extracellular pH was measured as 7.32 +/- 0.04 when using OVS, as compared to 7.39 +/- 0.03 when measured without OVS (N = 7 subjects). Conclusion: The extracellular P-i signal acquired from the human head using nonlocalized P-31 MRS contains a significant component likely contributed by peripheral blood and CSF in meninges that must be removed in order to use this signal as an endogenous probe for measuring extracellular pH and other properties in the brain.
引用
收藏
页码:1289 / 1297
页数:9
相关论文
共 50 条
  • [1] 31P T2s of phosphomonoesters, phosphodiesters, and inorganic phosphate in the human brain at 7T
    van der Kemp, Wybe J. M.
    Klomp, Dennis W. J.
    Wijnen, Jannie P.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 29 - 35
  • [2] Optimized 31P MRS in the human brain at 7T with a dedicated RF coil setup
    van de Bank, Bart L.
    Orzada, Stephan
    Smits, Frits
    Lagemaat, Miriam W.
    Rodgers, Christopher T.
    Bitz, Andreas K.
    Scheenen, Tom W. J.
    NMR IN BIOMEDICINE, 2015, 28 (11) : 1570 - 1578
  • [3] Unveiling extracellular inorganic phosphate signals from blood in human cardiac 31P NMR spectra
    Schmidt, O
    Bunse, M
    Dietze, GJ
    Lutz, O
    Jung, WI
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2001, 3 (04) : 325 - 329
  • [4] Feasibility of absolute quantification for 31P MRS at 7 T
    Purvis, Lucian A. B.
    Valkovic, Ladislav
    Robson, Matthew D.
    Rodgers, Christopher T.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 49 - 61
  • [5] Volumetric mapping of intra- and extracellular pH in the human brain using 31P MRSI at 7T
    Korzowski, Andreas
    Weinfurtner, Nina
    Mueller, Sebastian
    Breitling, Johannes
    Goerke, Steffen
    Schlemmer, Heinz-Peter
    Ladd, Mark E.
    Paech, Daniel
    Bachert, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (04) : 1707 - 1723
  • [6] Repeatability of 31P MRSI in the human brain at 7T with and without the nuclear Overhauser effect
    Lagemaat, Miriam W.
    van de Bank, Bart L.
    Sati, Pascal
    Li, Shizhe
    Maas, Marnix C.
    Scheenen, Tom W. J.
    NMR IN BIOMEDICINE, 2016, 29 (03) : 256 - 263
  • [7] 31P MRSI and 1H MRS at 7T: initial results in human breast cancer
    Klomp, Dennis W. J.
    van de Bank, Bart L.
    Raaijmakers, Alexander
    Korteweg, Mies A.
    Possanzini, Cecilia
    Boer, Vincent O.
    de Berg, Cornelius A. T. van
    van de Bosch, Maurice A. A. J.
    Luijten, Peter R.
    NMR IN BIOMEDICINE, 2011, 24 (10) : 1337 - 1342
  • [8] 31P SPECTROSCOPIC IMAGING AT 7T FOR LOCALIZATION OF SEIZURE ONSET
    Pan, Jullie W.
    Avdievich, N.
    Spencer, Dennis
    EPILEPSIA, 2008, 49 : 397 - 398
  • [9] 31P MRS Study of Hyperbaric Oxygenation Effects on Phosphate Metabolism of Normal Human Brain
    Manzhurtsev, A. V.
    Vasiukova, O. R.
    Sergeeva, V. V.
    Zaitseva, N. L.
    Menshchikov, P. E.
    Melnikov, I. A.
    Akhadov, T. A.
    Semenova, N. A.
    APPLIED MAGNETIC RESONANCE, 2018, 49 (07) : 679 - 686
  • [10] 31P MRS Study of Hyperbaric Oxygenation Effects on Phosphate Metabolism of Normal Human Brain
    A. V. Manzhurtsev
    O. R. Vasiukova
    V. V. Sergeeva
    N. L. Zaitseva
    P. E. Menshchikov
    I. A. Melnikov
    T. A. Akhadov
    N. A. Semenova
    Applied Magnetic Resonance, 2018, 49 : 679 - 686