CycleSeg: Simultaneous synthetic CT generation and unsupervised segmentation for MR-only radiotherapy treatment planning of prostate cancer

被引:1
|
作者
Luu, Huan Minh [1 ]
Yoo, Gyu Sang [2 ]
Park, Won [3 ,5 ]
Park, Sung-Hong [1 ,4 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Daejeon, South Korea
[2] Chungbuk Natl Univ Hosp, Dept Radiat Oncol, Cheongju, South Korea
[3] Samsung Med Ctr, Dept Radiat Oncol, Seoul, South Korea
[4] Korea Adv Inst Sci & Technol KAIST, Dept Bio & Brain Engn, Rm 1002,CMS E16 Bldg,291 Daehak Ro, Daejeon 34141, South Korea
[5] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Dept Radiat Oncol, Seoul 06351, South Korea
基金
新加坡国家研究基金会;
关键词
CycleSeg; deep learning; prostate; radiotherapy treatment planning; synthetic CT; unsupervised domain adaptation; AUTO-SEGMENTATION; IMAGE; VOLUMES; DELINEATION; ORGANS; TUMOR; RISK;
D O I
10.1002/mp.16976
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMR-only radiotherapy treatment planning is an attractive alternative to conventional workflow, reducing scan time and ionizing radiation. It is crucial to derive the electron density map or synthetic CT (sCT) from MR data to perform dose calculations to enable MR-only treatment planning. Automatic segmentation of relevant organs in MR images can accelerate the process by preventing the time-consuming manual contouring step. However, the segmentation label is available only for CT data in many cases.PurposeWe propose CycleSeg, a unified framework that generates sCT and corresponding segmentation from MR images without access to MR segmentation labelsMethodsCycleSeg utilizes the CycleGAN formulation to perform unpaired synthesis of sCT and image alignment. To enable MR (sCT) segmentation, CycleSeg incorporates unsupervised domain adaptation by using a pseudo-labeling approach with feature alignment in semantic segmentation space. In contrast to previous approaches that perform segmentation on MR data, CycleSeg could perform segmentation on both MR and sCT. Experiments were performed with data from prostate cancer patients, with 78/7/10 subjects in the training/validation/test sets, respectively.ResultsCycleSeg showed the best sCT generation results, with the lowest mean absolute error of 102.2 and the lowest Frechet inception distance of 13.0. CycleSeg also performed best on MR segmentation, with the highest average dice score of 81.0 and 81.1 for MR and sCT segmentation, respectively. Ablation experiments confirmed the contribution of the proposed components of CycleSeg.ConclusionCycleSeg effectively synthesized CT and performed segmentation on MR images of prostate cancer patients. Thus, CycleSeg has the potential to expedite MR-only radiotherapy treatment planning, reducing the prescribed scans and manual segmentation effort, and increasing throughput.
引用
收藏
页码:4365 / 4379
页数:15
相关论文
共 50 条
  • [31] Patient specific quality assurance for synthetic CT in MR-only radiotherapy of the abdomen
    Dal Bello, R.
    Lapaeva, M.
    Agustina, A.
    Wallimann, P.
    Gunther, M.
    Konukoglu, E.
    Andratschke, N.
    Guckenberger, M.
    Tanadini-Lang, S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S74 - S75
  • [32] Results of the ESTRO 2023 survey on the use of synthetic CT in MR-only radiotherapy
    Fusella, Marco
    Cusumano, Davide
    Alvarez-Andres, Emilie
    Dal Bello, Riccardo
    Dhont, Jennifer
    Garibaldi, Cristina
    Villegas, Fernanda
    Placidi, Lorenzo
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3801 - S3803
  • [33] Robustness of Conditional Generative Adversarial Networks in Generating Head and Neck Synthetic CT Images for MR-Only Radiotherapy Treatment Planning
    Klages, P.
    Benslimane, I.
    Riyahi, S.
    Jiang, J.
    Hunt, M.
    Deasy, J.
    Veeraraghavan, H.
    Tyagi, N.
    MEDICAL PHYSICS, 2019, 46 (06) : E295 - E296
  • [34] Dosimetric and volumetric evaluation of MR-only planning for radiotherapy of rectal cancer
    Vieira, S.
    Pares, O.
    Loucao, N.
    Stroom, J.
    Santiago, I.
    Greco, C.
    Matos, C.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1025 - S1025
  • [35] Clinical Validation of Commercial AI-Generated Synthetic CT Images for Prostate MR-Only Radiotherapy Workflows
    Parchur, A. K.
    Zarenia, M.
    Gage, C.
    Paulson, E. S.
    Ahunbay, E. E.
    MEDICAL PHYSICS, 2024, 51 (09) : 6619 - 6619
  • [36] Joint MR to CT Synthesis and Segmentation for MR-only Pediatric Brain Radiation Therapy Planning
    Mekki, Lina
    Acharya, Sahaja
    Ladra, Matthew
    Lee, Junghoon
    IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, MEDICAL IMAGING 2024, 2024, 12928
  • [37] Patient-Specific Synthetic CT Generation for MRI-Only Prostate Radiotherapy Treatment Planning
    Yang, X.
    Lei, Y.
    Wang, T.
    Patel, P.
    Dhabaan, A.
    Jiang, X.
    Shim, H.
    Mao, H.
    Curran, W.
    Jani, A.
    Liu, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E701 - E702
  • [38] Feasibility of MR-only proton dose calculations for prostate cancer radiotherapy using a commercial pseudo-CT generation method
    Maspero, Matteo
    van den Berg, Cornelis A. T.
    Landry, Guillaume
    Belka, Claus
    Parodi, Katia
    Seevinck, Peter R.
    Raaymakers, Bas W.
    Kurz, Christopher
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (24): : 9159 - 9176
  • [39] Dosimetric Evaluation of Magnetic Resonance-Generated Synthetic CT for MR-Only Rectal Cancer Radiotherapy
    Wang, H.
    Du, K.
    Qu, J.
    Chandarana, H.
    Das, I.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [40] The benefit of MR-only radiotherapy treatment planning for anal and rectal cancers: A planning study
    Bird, David
    Nix, Michael G.
    McCallum, Hazel
    Teo, Mark
    Gilbert, Alexandra
    Casanova, Nathalie
    Cooper, Rachel
    Buckley, David L.
    Sebag-Montefiore, David
    Speight, Richard
    Al-Qaisieh, Bashar
    Henry, Ann M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (11): : 41 - 53