CycleSeg: Simultaneous synthetic CT generation and unsupervised segmentation for MR-only radiotherapy treatment planning of prostate cancer

被引:1
|
作者
Luu, Huan Minh [1 ]
Yoo, Gyu Sang [2 ]
Park, Won [3 ,5 ]
Park, Sung-Hong [1 ,4 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Daejeon, South Korea
[2] Chungbuk Natl Univ Hosp, Dept Radiat Oncol, Cheongju, South Korea
[3] Samsung Med Ctr, Dept Radiat Oncol, Seoul, South Korea
[4] Korea Adv Inst Sci & Technol KAIST, Dept Bio & Brain Engn, Rm 1002,CMS E16 Bldg,291 Daehak Ro, Daejeon 34141, South Korea
[5] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Dept Radiat Oncol, Seoul 06351, South Korea
基金
新加坡国家研究基金会;
关键词
CycleSeg; deep learning; prostate; radiotherapy treatment planning; synthetic CT; unsupervised domain adaptation; AUTO-SEGMENTATION; IMAGE; VOLUMES; DELINEATION; ORGANS; TUMOR; RISK;
D O I
10.1002/mp.16976
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMR-only radiotherapy treatment planning is an attractive alternative to conventional workflow, reducing scan time and ionizing radiation. It is crucial to derive the electron density map or synthetic CT (sCT) from MR data to perform dose calculations to enable MR-only treatment planning. Automatic segmentation of relevant organs in MR images can accelerate the process by preventing the time-consuming manual contouring step. However, the segmentation label is available only for CT data in many cases.PurposeWe propose CycleSeg, a unified framework that generates sCT and corresponding segmentation from MR images without access to MR segmentation labelsMethodsCycleSeg utilizes the CycleGAN formulation to perform unpaired synthesis of sCT and image alignment. To enable MR (sCT) segmentation, CycleSeg incorporates unsupervised domain adaptation by using a pseudo-labeling approach with feature alignment in semantic segmentation space. In contrast to previous approaches that perform segmentation on MR data, CycleSeg could perform segmentation on both MR and sCT. Experiments were performed with data from prostate cancer patients, with 78/7/10 subjects in the training/validation/test sets, respectively.ResultsCycleSeg showed the best sCT generation results, with the lowest mean absolute error of 102.2 and the lowest Frechet inception distance of 13.0. CycleSeg also performed best on MR segmentation, with the highest average dice score of 81.0 and 81.1 for MR and sCT segmentation, respectively. Ablation experiments confirmed the contribution of the proposed components of CycleSeg.ConclusionCycleSeg effectively synthesized CT and performed segmentation on MR images of prostate cancer patients. Thus, CycleSeg has the potential to expedite MR-only radiotherapy treatment planning, reducing the prescribed scans and manual segmentation effort, and increasing throughput.
引用
收藏
页码:4365 / 4379
页数:15
相关论文
共 50 条
  • [21] Clinical commissioning of MR-Only Prostate treatment planning workflow
    Bolard, G.
    Bulling, S.
    Hejira, N.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 852 - 852
  • [22] Clinical Commissioning of MR-Only Prostate Treatment Planning Workflow
    Bolard, G.
    Bulling, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3721 - 3721
  • [23] A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck
    Maspero, M.
    Seevinck, P. R.
    Meijer, G. J.
    Lagendijk, J. J. W.
    Viergever, M. A.
    van den Berg, C. A. T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3316 - 3316
  • [24] Joint MR to CT Synthesis and Organs-at-Risk Segmentation with Uncertainty Estimation for MR-Only Brain Radiotherapy Planning
    Mekki, L.
    Acharya, S.
    Ladra, M.
    Lee, J.
    MEDICAL PHYSICS, 2024, 51 (09) : 6618 - 6618
  • [25] Are cone beam CT image matching skills transferrable from planning CT to planning MRI for MR-only prostate radiotherapy?
    Brooks, Rachel L.
    McCallum, Hazel M.
    Pearson, Rachel A.
    Pilling, Karen
    Wyatt, Jonathan
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1123):
  • [26] Abdominal Synthetic CT Generation for MR-Only Liver Radiotherapy Using Conditional Generative Adversarial Network
    Fu, J.
    Santhanam, A.
    Cao, M.
    Guo, M.
    Singhrao, K.
    Yu, V.
    Ruan, D.
    Low, D.
    Lewis, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E701 - E701
  • [27] Dosimetric evaluation of deep learning based synthetic-CT generation for MR-only brain radiotherapy
    Dinkla, A. M.
    Wolterink, J. M.
    Maspero, M.
    Savenije, M. H. F.
    Verhoeff, J. J. C.
    Isgum, I.
    Seevinck, P. R.
    Lagendijk, J. J. W.
    Van den Berg, C. A. T.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S151 - S151
  • [28] Deep learning-based synthetic CT generation for MR-only radiotherapy of prostate cancer patients with 0.35T MRI linear accelerator
    Farjam, Reza
    Nagar, Himanshu
    Kathy Zhou, Xi
    Ouellette, David
    Chiara Formenti, Silvia
    DeWyngaert, J. Keith
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08): : 93 - 104
  • [29] The rationale for MR-only delineation and planning: retrospective CT-MR registration and target volume analysis for prostate radiotherapy
    Ilamurugu, Arivarasan
    Chandrasekaran, Anu Radha
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) : 265 - 272
  • [30] Bony structure enhanced synthetic CT generation using Dixon sequences for pelvis MR-only radiotherapy
    Liang, Xiao
    Yen, Allen
    Bai, Ti
    Godley, Andrew
    Shen, Chenyang
    Wu, Junjie
    Meng, Boyu
    Lin, Mu-Han
    Medin, Paul
    Yan, Yulong
    Owrangi, Amir
    Desai, Neil
    Hannan, Raquibul
    Garant, Aurelie
    Jiang, Steve
    Deng, Jie
    MEDICAL PHYSICS, 2023, 50 (12) : 7368 - 7382