Simultaneous time-of-flight MR angiography and quantitative susceptibility mapping with key time-of-flight features

被引:0
|
作者
De, Ashmita [1 ]
Grenier, Justin [1 ]
Wilman, Alan H. [1 ,2 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB, Canada
[2] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
基金
加拿大健康研究院;
关键词
quantitative susceptibility mapping; susceptibility-weighted imaging; time-of-flight MR angiography; MAGNETIC-RESONANCE ANGIOGRAPHY; BRAIN; ACQUISITION; VENOGRAPHY; SEQUENCE; ARTERIES; VOLUME; VEINS; IRON; SWI;
D O I
10.1002/nbm.5079
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A technique for combined time-of-flight (TOF) MR angiography (MRA) and quantitative susceptibility mapping (QSM) was developed with key features of standard three-dimensional (3D) TOF acquisitions, including multiple overlapping thin slab acquisition (MOTSA), ramped RF excitation, and venous saturation. The developed triple-echo 3D TOF-QSM sequence enabled TOF-MRA, susceptibility-weighted imaging (SWI), QSM, and R2* mapping. The effects of ramped RF, resolution, flip angle, venous saturation, and MOTSA were studied on QSM. Six volunteers were scanned at 3 T with the developed sequence, conventional TOF-MRA, and conventional SWI. Quantitative comparison of susceptibility values on QSM and normalized arterial and venous vessel-to-background contrasts on TOF and SWI were performed. The ramped RF excitation created an inherent phase variation in the raw phase. A generic correction factor was computed to remove the phase variation to obtain QSM without artifacts from the TOF-QSM sequence. No statistically significant difference was observed between the developed and standard QSM sequence for susceptibility values. However, maintaining standard TOF features led to compromises in signal-to-noise ratio for QSM and SWI, arising from the use of MOTSA rather than one large 3D slab, higher TOF spatial resolution, increased TOF background suppression due to larger flip angles, and reduced venous signal from venous saturation. In terms of vessel contrast, veins showed higher normalized contrast on SWI derived from TOF-QSM than the standard SWI sequence. While fast flowing arteries had reduced contrast compared with standard TOF-MRA, no statistical difference was observed for slow flowing arteries. Arterial contrast differences largely arise from the longer TR used in TOF-QSM over standard TOF-MRA to accommodate additional later echoes for SWI. In conclusion, although the sequence has a longer TR and slightly lower arterial contrast, provided an adequate correction is made for ramped RF excitation effects on phase, QSM may be performed from a multiecho sequence that includes all key TOF features, thus enabling simultaneous TOF-MRA, SWI, QSM, and R2* map computation. A triple-echo 3D sequence was developed with key time-of-flight (TOF) MR angiography (MRA) features, including ramped RF excitation, venous saturation, and multiple overlapping thin slab acquisition (MOTSA), enabling TOF-MRA, susceptibility-weighted imaging (SWI), quantitative susceptibility mapping (QSM), and transverse relaxation rate (R2*) mapping. The effects of TOF features on QSM were studied.image
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Malignant glioma - Evaluation with 3D time-of-flight MR angiography
    Kadota, T
    Nakagawa, H
    Kuroda, C
    ACTA RADIOLOGICA, 1998, 39 (03) : 227 - 232
  • [42] Noninvasive Depiction of the Lenticulostriate Arteries with Time-of-Flight MR Angiography at 7.0 T
    Hendrikse, Jeroen
    Zwanenburg, Jaco J.
    Visser, Fredy
    Takahara, Taro
    Luijten, Peter
    CEREBROVASCULAR DISEASES, 2008, 26 (06) : 624 - 629
  • [43] A laminar flow model for 3D Time-of-Flight MR Angiography
    Chen, DJ
    Hedges, LK
    Yu, CX
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2167 - 2170
  • [44] 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY - APPLICATIONS IN THE ABDOMEN AND THORAX
    LEWIN, JS
    LAUB, G
    HAUSMANN, R
    RADIOLOGY, 1991, 179 (01) : 261 - 264
  • [45] Evaluation of Fourier rebinning of time-of-flight PET data to non time-of-flight
    Li, Quanzheng
    Cho, S.
    Ahn, S.
    Ren, R.
    Leahy, R.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [46] OPTIMIZING 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY WITH VARIABLE REPETITION TIME
    TKACH, JA
    LIN, WL
    DUDA, JJ
    HAACKE, EM
    MASARYK, TJ
    RADIOLOGY, 1994, 191 (03) : 805 - 811
  • [47] Time-of-flight magnetic resonance angiography at 7 tesla
    Heverhagen, Johannes T.
    Bourekas, Eric
    Sammet, Steffen
    Knopp, Michael V.
    Schmalbrock, Petra
    INVESTIGATIVE RADIOLOGY, 2008, 43 (08) : 568 - 573
  • [48] Editorial for "Quantitative Time-of-Flight Head Magnetic Resonance Angiography of Cerebrovascular Disease"
    Balu, Niranjan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (01) : 413 - 414
  • [49] TIME-OF-FLIGHT TIME-OF-FLIGHT TANDEM MASS-SPECTROMETRY OF MULTIPLE INCIDENT IONS
    JARDINE, DR
    ALDERDICE, DS
    DERRICK, PJ
    ORGANIC MASS SPECTROMETRY, 1991, 26 (10): : 915 - 916
  • [50] Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET
    Rezaei, Ahmadreza
    Nuyts, Johan
    Defrise, Michel
    Bal, Girish
    Michel, Christian
    Conti, Maurizio
    Watson, Charles
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2375 - 2382