Simultaneous time-of-flight MR angiography and quantitative susceptibility mapping with key time-of-flight features

被引:0
|
作者
De, Ashmita [1 ]
Grenier, Justin [1 ]
Wilman, Alan H. [1 ,2 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB, Canada
[2] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
基金
加拿大健康研究院;
关键词
quantitative susceptibility mapping; susceptibility-weighted imaging; time-of-flight MR angiography; MAGNETIC-RESONANCE ANGIOGRAPHY; BRAIN; ACQUISITION; VENOGRAPHY; SEQUENCE; ARTERIES; VOLUME; VEINS; IRON; SWI;
D O I
10.1002/nbm.5079
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A technique for combined time-of-flight (TOF) MR angiography (MRA) and quantitative susceptibility mapping (QSM) was developed with key features of standard three-dimensional (3D) TOF acquisitions, including multiple overlapping thin slab acquisition (MOTSA), ramped RF excitation, and venous saturation. The developed triple-echo 3D TOF-QSM sequence enabled TOF-MRA, susceptibility-weighted imaging (SWI), QSM, and R2* mapping. The effects of ramped RF, resolution, flip angle, venous saturation, and MOTSA were studied on QSM. Six volunteers were scanned at 3 T with the developed sequence, conventional TOF-MRA, and conventional SWI. Quantitative comparison of susceptibility values on QSM and normalized arterial and venous vessel-to-background contrasts on TOF and SWI were performed. The ramped RF excitation created an inherent phase variation in the raw phase. A generic correction factor was computed to remove the phase variation to obtain QSM without artifacts from the TOF-QSM sequence. No statistically significant difference was observed between the developed and standard QSM sequence for susceptibility values. However, maintaining standard TOF features led to compromises in signal-to-noise ratio for QSM and SWI, arising from the use of MOTSA rather than one large 3D slab, higher TOF spatial resolution, increased TOF background suppression due to larger flip angles, and reduced venous signal from venous saturation. In terms of vessel contrast, veins showed higher normalized contrast on SWI derived from TOF-QSM than the standard SWI sequence. While fast flowing arteries had reduced contrast compared with standard TOF-MRA, no statistical difference was observed for slow flowing arteries. Arterial contrast differences largely arise from the longer TR used in TOF-QSM over standard TOF-MRA to accommodate additional later echoes for SWI. In conclusion, although the sequence has a longer TR and slightly lower arterial contrast, provided an adequate correction is made for ramped RF excitation effects on phase, QSM may be performed from a multiecho sequence that includes all key TOF features, thus enabling simultaneous TOF-MRA, SWI, QSM, and R2* map computation. A triple-echo 3D sequence was developed with key time-of-flight (TOF) MR angiography (MRA) features, including ramped RF excitation, venous saturation, and multiple overlapping thin slab acquisition (MOTSA), enabling TOF-MRA, susceptibility-weighted imaging (SWI), quantitative susceptibility mapping (QSM), and transverse relaxation rate (R2*) mapping. The effects of TOF features on QSM were studied.image
引用
收藏
页数:13
相关论文
共 50 条
  • [31] TIME-OF-FLIGHT DOSIMETRY
    SHAPIRO, P
    THEUS, RB
    SURRATT, RE
    AUGUST, LS
    ATTIX, FH
    BONDELID, RO
    ROGERS, CC
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1974, 19 (OCT27): : 52 - 53
  • [32] Orbitrap or Time-of-flight?
    Kaufmann, Anton
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [33] Increased Resolution of Time-of-Flight MR Angiography at Higher Field Strength Response
    Shi, Zhang
    Zhao, Xueying
    Zeng, Mengsu
    Wang, He
    RADIOLOGY, 2023, 307 (04)
  • [34] MOYAMOYA DISEASE - DIAGNOSIS WITH 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    YAMADA, I
    MATSUSHIMA, Y
    SUZUKI, S
    RADIOLOGY, 1992, 184 (03) : 773 - 778
  • [35] Postcontrast time-of-flight MR angiography demonstrating collateral flow in acute stroke
    Sohn, Chul-Ho
    Sohn, Sung-Il
    Chang, Hyuk-Won
    Demchuk, Andrew M.
    STROKE, 2007, 38 (04) : 1132 - 1133
  • [36] Time-of-flight MR angiography of different patterns of internal carotid artery dissection
    Brunereau, L
    Levy, C
    Djouhri, H
    MarsotDupuch, K
    Bousser, MG
    Tubiana, J
    RADIOLOGY, 1996, 201 : 107 - 107
  • [37] Lack of flow on time-of-flight MR angiography does not always indicate occlusion
    Mair, Grant
    BJR CASE REPORTS, 2016, 2 (01):
  • [38] 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY IN THE EVALUATION OF CEREBRAL ANEURYSMS
    SEVICK, RJ
    TSURUDA, JS
    SCHMALBROCK, P
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) : 874 - 881
  • [39] Autocorrection of three-dimensional time-of-flight MR angiography of the circle of Willis
    McGee, KP
    Felmlee, JP
    Jack, CR
    Manduca, A
    Riederer, SJ
    Ehman, RL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 513 - 518
  • [40] Magnetization transfer on in vitro circulating blood: Implications for time-of-flight MR angiography
    Dousset, V
    Degreze, P
    Mieze, S
    Sesay, M
    BasseCathalinat, B
    Caille, JM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06): : 786 - 788