Application of O-RADS US combined with MV-Flow to diagnose ovarian-adnexal tumors

被引:0
|
作者
Ruan, Linlin [1 ]
Liu, Hui [1 ]
Xiang, Hong [1 ]
Ni, Yongkang [2 ]
Feng, Yuling [1 ]
Zhou, Huili [1 ]
Qi, Mengtong [1 ]
机构
[1] Xinjiang Med Univ, Xinjiang Key Lab Ultrasound Med, Affiliated Hosp 1, Obstet & Gynecol Ultrasound Dept, Urumqi, Peoples R China
[2] Xinjiang Med Univ, Sch Publ Hlth, Urumqi, Peoples R China
关键词
Ovarian-adnexal ultrasound reporting and data system; O-RADS US; MV-Flow; VIMV; Ovarian-adnexal mass; VALIDATION; SYSTEM;
D O I
10.14366/usg.23061
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses. Methods: A total of 112 ovarian-adnexal masses ( 81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VIMV) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency. Results: Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VIMV was >= 7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1). Conclusion: O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses.
引用
收藏
页码:15 / 24
页数:10
相关论文
共 50 条
  • [41] Tumor biomarkers contribute to the diagnosis and clinical management of the O-RADS MRI risk stratification system for epithelial ovarian tumors
    Shengjie Xu
    Weijian Gong
    Xiyi Chen
    Jiatong Wang
    Yuan Zhu
    Tao Zhang
    Yun Gu
    Jinxia Zheng
    Juan Xu
    World Journal of Surgical Oncology, 23 (1)
  • [42] Prospective comparative trial comparing O-RADS, IOTA ADNEX model, and RMI score for preoperative evaluation of adnexal masses for prediction of ovarian cancer
    Poonyakanok, Vitcha
    Tanmahasamut, Prasong
    Jaishuen, Atthapon
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2023, 49 (05) : 1412 - 1417
  • [43] Clinical value of O-RADS combined with serum CA125 and HE4 for the diagnosis of ovarian tumours
    Wang, Rongling
    Li, Xiumei
    Li, Shuqin
    Fang, Shibao
    Zhao, Cheng
    Yang, Hui
    Yang, Zongli
    ACTA RADIOLOGICA, 2023, 64 (02) : 821 - 828
  • [44] Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification
    Pelayo, Mar
    Sancho-Sauco, Javier
    Sanchez-Zurdo, Javier
    Perez-Mies, Belen
    Abarca-Martinez, Leopoldo
    Cancelo-Hidalgo, Ma Jesus
    Sainz-Bueno, Jose Antonio
    Alcazar, Juan Luis
    Pelayo-Delgado, Irene
    DIAGNOSTICS, 2023, 13 (17)
  • [45] Comparison of performance between O-RADS, IOTA simple rules risk assessment and ADNEX model in the discrimination of ovarian Brenner tumors
    Shang, JianHong
    Lei, Ting
    Wu, LiHong
    Lin, MeiFang
    Xie, HongNing
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2023, 308 (03) : 961 - 970
  • [46] Comparison of performance between O-RADS, IOTA simple rules risk assessment and ADNEX model in the discrimination of ovarian Brenner tumors
    JianHong Shang
    Ting Lei
    LiHong Wu
    MeiFang Lin
    HongNing Xie
    Archives of Gynecology and Obstetrics, 2023, 308 : 961 - 970
  • [47] Does Combing O-RADS US and CA-125 Improve Diagnostic Accuracy in Assessing Adnexal Malignancy Risk in Women with Different Menopausal Status?
    Wu, Manli
    Wang, Qingjuan
    Zhang, Man
    Cao, Junyan
    Chen, Ying
    Zheng, Jian
    Luo, Liping
    Su, Manting
    Lin, Xin
    Kuang, Xiaohong
    Zhang, Xinling
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (03) : 675 - 685
  • [48] Differentiating Benign From Malignant Ovarian Masses With Solid Components: Diagnostic Performance of CEUS Combined With IOTA Simple Rules and O-RADS
    Lu, Beilei
    He, Wanyuan
    Liu, Chang
    Wang, Pan
    Yang, Ping
    Zhao, Zhengyong
    Qi, Jiuling
    Huang, Beijian
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (09): : 1449 - 1458
  • [49] Differentiating struma ovarii from FIGO stage I malignant ovarian tumors in O-RADS MRI 5 lesions: a targeted cohort study
    Ye, Rongping
    Zheng, Yao
    Pan, Feng
    Wang, Huifang
    Yan, Chuan
    Li, Yueming
    ABDOMINAL RADIOLOGY, 2024, : 1426 - 1434
  • [50] Diagnostic performance of IOTA SR and O-RADS combined with CA125, HE4, and risk of malignancy algorithm to distinguish benign and malignant adnexal masses
    Yang, Yang
    Ju, Hao
    Huang, Ying
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 165