Comparison of radium-226 separation methods based on chromatographic and extraction resins for its determination by ICP-MS in drinking waters

被引:3
|
作者
Roulier, Marine [1 ]
Baya, Pascale Anabelle [2 ]
Roberge, Steeve [2 ]
Lariviere, Dominic [1 ]
机构
[1] Univ Laval, Dept Chim, Lab Radioecol, Quebec City, PQ G1V 0A6, Canada
[2] Quebec Minist Environm Lutte Changements Climat, Div Chim Inorgan Milieu, Direct Anal Chim, Direct Gen Coordinat Sci, Faune & Parcs, Quebec City, PQ, Canada
来源
JOURNAL OF MASS SPECTROMETRY | 2024年 / 59卷 / 02期
基金
加拿大自然科学与工程研究理事会;
关键词
chromatographic resin; drinking waters; environmental; ICP-MS; radium; MASS-SPECTROMETRY; ENVIRONMENTAL-SAMPLES; RAPID-DETERMINATION; NATURAL-WATERS; RADIUM; PRECONCENTRATION; QUANTIFICATION;
D O I
10.1002/jms.5005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the past century, human activities have contributed to the release of 226Ra (t1/2 = 1,600 y) in the environment, increasing the potential risks for human exposure and thus prompting scientists to monitor it. Inductively coupled plasma mass spectrometry (ICP-MS) is an alternative to alpha-spectrometry for the quantification of 226Ra. However, the performances of radioanalytical procedures are rarely compared in a rigorous framework, which means that researchers may choose one on subjective factors or guesses.This article compares five published methods for the separation and preconcentration of 226Ra in drinking waters based on chromatographic and extraction resins prior to its analysis by ICP-MS. We evaluated the turnaround time, generated wastes, and final cost of each protocol as the economic aspect can be an important criterion when selecting a method, particularly for sustainable environmental monitoring. Our results showed that 226Ra was successfully separated and preconcentrated, yielding recoveries ranging between 84% and 105%. Method detection and quantification limits of respectively 2-7 fg L-1 (0.1-0.3 mBq L-1) and 6-24 fg L-1 (0.2-0.9 mBq L-1) were achieved when the separation method was coupled with ICP-MS. The turnaround times ranged between 6 and 21 hours, whereas the cost of the methods varied between 40 and 132 USD.This study highlights for the first time that methodologies recently published on the evaluation of 226Ra levels in drinking water by ICP-MS have comparable figures of merit. Our results offer essential insights into the selection of the most suitable separation method.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Determination of trace amounts of Si in iron and steel using gel chromatographic separation followed by isotopic dilution ICP-MS
    Hanada, K
    Fujimoto, K
    Shimura, M
    Yoshioka, K
    BUNSEKI KAGAKU, 1997, 46 (09) : 749 - 753
  • [32] Extraction chromatographic separation of Y, REE, Bi, Th, and U from the matrix suitable for their determination in pure iron and Low-Alloyed steels by ICP-MS and ICP-AES
    Vasili K. Karandashev
    Alexander N. Turanov
    Heinz-Martin Kuß
    Iris Kumpmann
    Ludmila V. Zadnepruk
    Vladimir E. Baulin
    Microchimica Acta, 1998, 130 : 47 - 54
  • [33] Determination of rare earth elements in uranium materials by ICP-MS and ICP-OES after matrix separation by solvent extraction with TEHP
    Baghaliannejad, Reza
    Aghahoseini, Masoud
    Amini, Mohammad K.
    TALANTA, 2021, 222
  • [34] Determination of rare earth elements in uranium materials by ICP-MS and ICP-OES after matrix separation by solvent extraction with TEHP
    Baghaliannejad, Reza
    Aghahoseini, Masoud
    Amini, Mohammad K.
    Amini, Mohammad K. (mkamini@chem.ui.ac.ir), 1600, Elsevier B.V. (222):
  • [35] Extraction chromatographic separation of Y, REE, Bi, Th, and U from the matrix suitable for their determination in pure iron and low-alloyed steels by ICP-MS and ICP-AES
    Karandashev, VK
    Turanov, AN
    Kuss, HM
    Kumpmann, I
    Zadnepruk, LV
    Baulin, VE
    MIKROCHIMICA ACTA, 1998, 130 (1-2) : 47 - 54
  • [36] Determination of plutonium concentration and its isotopic ratio in environmental materials by ICP-MS after separation using ion-exchange and extraction chromatography
    Muramatsu, Y
    Uchida, S
    Tagami, K
    Yoshida, S
    Fujikawa, T
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (05) : 859 - 865
  • [37] Comparison of Microwave Assisted Acid Digestion Methods for ICP-MS Determination of Total Arsenic in Fish Tissue
    Ghanthimathi, S.
    Aminah, A.
    Salmijah, S.
    Ujang, T.
    Izzah, A. Nurul
    SAINS MALAYSIANA, 2012, 41 (12): : 1557 - 1564
  • [38] Comparison of Three Digestion Methods for Heavy Metals Determination in Soils and Sediments Materials by ICP-MS Technique
    Geana, E. I.
    Iordache, A. M.
    Voica, C.
    Culea, M.
    Ionete, R. E.
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (12) : 5213 - 5216
  • [39] Comparison of alkaline fusion and acid digestion methods for the determination of rhenium in rock and soil samples by ICP-MS
    Uchida, S
    Tagami, K
    Tabei, K
    ANALYTICA CHIMICA ACTA, 2005, 535 (1-2) : 317 - 323
  • [40] Comparison of multiple preservation and digestion methods for determination of tungsten concentrations in environmental media using ICP-MS
    Song, Lei
    Yang, Fei
    Bostick, Benjamin C.
    Du, Huihui
    Dai, Yu
    Li, Chao
    Sun, Jing
    Liu, Chengshuai
    TALANTA, 2024, 276