Comparison of radium-226 separation methods based on chromatographic and extraction resins for its determination by ICP-MS in drinking waters

被引:3
|
作者
Roulier, Marine [1 ]
Baya, Pascale Anabelle [2 ]
Roberge, Steeve [2 ]
Lariviere, Dominic [1 ]
机构
[1] Univ Laval, Dept Chim, Lab Radioecol, Quebec City, PQ G1V 0A6, Canada
[2] Quebec Minist Environm Lutte Changements Climat, Div Chim Inorgan Milieu, Direct Anal Chim, Direct Gen Coordinat Sci, Faune & Parcs, Quebec City, PQ, Canada
来源
JOURNAL OF MASS SPECTROMETRY | 2024年 / 59卷 / 02期
基金
加拿大自然科学与工程研究理事会;
关键词
chromatographic resin; drinking waters; environmental; ICP-MS; radium; MASS-SPECTROMETRY; ENVIRONMENTAL-SAMPLES; RAPID-DETERMINATION; NATURAL-WATERS; RADIUM; PRECONCENTRATION; QUANTIFICATION;
D O I
10.1002/jms.5005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the past century, human activities have contributed to the release of 226Ra (t1/2 = 1,600 y) in the environment, increasing the potential risks for human exposure and thus prompting scientists to monitor it. Inductively coupled plasma mass spectrometry (ICP-MS) is an alternative to alpha-spectrometry for the quantification of 226Ra. However, the performances of radioanalytical procedures are rarely compared in a rigorous framework, which means that researchers may choose one on subjective factors or guesses.This article compares five published methods for the separation and preconcentration of 226Ra in drinking waters based on chromatographic and extraction resins prior to its analysis by ICP-MS. We evaluated the turnaround time, generated wastes, and final cost of each protocol as the economic aspect can be an important criterion when selecting a method, particularly for sustainable environmental monitoring. Our results showed that 226Ra was successfully separated and preconcentrated, yielding recoveries ranging between 84% and 105%. Method detection and quantification limits of respectively 2-7 fg L-1 (0.1-0.3 mBq L-1) and 6-24 fg L-1 (0.2-0.9 mBq L-1) were achieved when the separation method was coupled with ICP-MS. The turnaround times ranged between 6 and 21 hours, whereas the cost of the methods varied between 40 and 132 USD.This study highlights for the first time that methodologies recently published on the evaluation of 226Ra levels in drinking water by ICP-MS have comparable figures of merit. Our results offer essential insights into the selection of the most suitable separation method.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Hyphenation of flow injection on-line preconcentration and ICP-MS for the rapid determination of 226Ra in natural waters
    Benkhedda, K
    Larivière, D
    Scott, S
    Evans, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (06) : 523 - 528
  • [22] Micro-extraction procedures for the determination of Ra-226 in well waters by SF-ICP-MS
    Larivière, D
    Epov, VN
    Reiber, KM
    Cornett, RJ
    Evans, RD
    ANALYTICA CHIMICA ACTA, 2005, 528 (02) : 175 - 182
  • [23] Determination of eleven small selenium species in human urine by chromatographic-coupled ICP-MS methods
    Hildebrand, Joerg
    Greiner, Annette
    Drexler, Hans
    Goeen, Thomas
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2020, 61
  • [24] Rapid Determination of Technetium-99 in Large Volume Seawater Samples Using Sequential Injection Extraction Chromatographic Separation and ICP-MS Measurement
    Shi, Keliang
    Qiao, Jixin
    Wu, Wangsuo
    Roos, Per
    Hou, Xiaolin
    ANALYTICAL CHEMISTRY, 2012, 84 (15) : 6783 - 6789
  • [25] Determination of trace amounts of Si and P in iron and steel using gel chromatographic separation followed by ICP-MS
    Hanada, K
    Fujimoto, K
    Shimura, M
    Yoshioka, K
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1998, 167 (02): : 383 - 388
  • [26] Determination of trace amounts of mercury, lead and cadmium in steels by ICP-MS after ion exchange chromatographic separation
    Fujimoto, K
    Chino, A
    BUNSEKI KAGAKU, 2006, 55 (04) : 245 - 249
  • [27] Quantification of 226Ra at environmental relevant levels in natural waters by ICP-MS: Optimization, validation and limitations of an extraction and preconcentration approach
    Lagace, Francois
    Foucher, Delphine
    Surette, Celine
    Clarisse, Olivier
    TALANTA, 2017, 167 : 658 - 665
  • [28] Comparison of ICP-MS and Two Other Analytical Methods for Determination of Selenium Content in Cordyceps Militaris
    Wang Ying
    Tie Mei
    Kang Ping-li
    Lue Yong-tong
    Ben Song-bin
    Chen Chang-lan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (03) : 815 - 818
  • [29] Comparison of Open Digestion Methods for the Determination of Rare Earth Elements in Plant Samples by ICP-MS
    Masson, P.
    Dalix, T.
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2016, 47 (16) : 1866 - 1874
  • [30] Chromatographic Separation of Cd from Plants via Anion Exchange Resin for an Isotope Determination by Multiple Collector ICP-MS
    Wei, Rongfei
    Guo, Qingjun
    Wen, Hanjie
    Peters, Marc
    Yang, Junxing
    Tian, Liyan
    Han, Xiaokun
    ANALYTICAL SCIENCES, 2017, 33 (03) : 335 - 341