Comparison of radium-226 separation methods based on chromatographic and extraction resins for its determination by ICP-MS in drinking waters

被引:3
|
作者
Roulier, Marine [1 ]
Baya, Pascale Anabelle [2 ]
Roberge, Steeve [2 ]
Lariviere, Dominic [1 ]
机构
[1] Univ Laval, Dept Chim, Lab Radioecol, Quebec City, PQ G1V 0A6, Canada
[2] Quebec Minist Environm Lutte Changements Climat, Div Chim Inorgan Milieu, Direct Anal Chim, Direct Gen Coordinat Sci, Faune & Parcs, Quebec City, PQ, Canada
来源
JOURNAL OF MASS SPECTROMETRY | 2024年 / 59卷 / 02期
基金
加拿大自然科学与工程研究理事会;
关键词
chromatographic resin; drinking waters; environmental; ICP-MS; radium; MASS-SPECTROMETRY; ENVIRONMENTAL-SAMPLES; RAPID-DETERMINATION; NATURAL-WATERS; RADIUM; PRECONCENTRATION; QUANTIFICATION;
D O I
10.1002/jms.5005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the past century, human activities have contributed to the release of 226Ra (t1/2 = 1,600 y) in the environment, increasing the potential risks for human exposure and thus prompting scientists to monitor it. Inductively coupled plasma mass spectrometry (ICP-MS) is an alternative to alpha-spectrometry for the quantification of 226Ra. However, the performances of radioanalytical procedures are rarely compared in a rigorous framework, which means that researchers may choose one on subjective factors or guesses.This article compares five published methods for the separation and preconcentration of 226Ra in drinking waters based on chromatographic and extraction resins prior to its analysis by ICP-MS. We evaluated the turnaround time, generated wastes, and final cost of each protocol as the economic aspect can be an important criterion when selecting a method, particularly for sustainable environmental monitoring. Our results showed that 226Ra was successfully separated and preconcentrated, yielding recoveries ranging between 84% and 105%. Method detection and quantification limits of respectively 2-7 fg L-1 (0.1-0.3 mBq L-1) and 6-24 fg L-1 (0.2-0.9 mBq L-1) were achieved when the separation method was coupled with ICP-MS. The turnaround times ranged between 6 and 21 hours, whereas the cost of the methods varied between 40 and 132 USD.This study highlights for the first time that methodologies recently published on the evaluation of 226Ra levels in drinking water by ICP-MS have comparable figures of merit. Our results offer essential insights into the selection of the most suitable separation method.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Direct analysis of radium-226 in sediment by ICP-MS: an analytical challenge?
    Ben Yaala, Hamza
    Fniter, Rihab
    Foucher, Delphine
    Clarisse, Olivier
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (08) : 1597 - 1605
  • [2] ON ICP-MS DETERMINATION OF URANIUM IN DRINKING, GROUND AND MINERAL WATERS
    Georgiev, Valentin
    Dakova, Ivanka
    Karadjova, Irina
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2023, 76 (04): : 525 - 531
  • [3] Extraction and determination of Cs in natural waters by ICP-MS after ion exchange separation
    Epov, VN
    Lariviere, D
    Reiber, KM
    Evans, RD
    Cornett, RJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (09) : 1225 - 1229
  • [4] Simple and sensitive determination of radium-226 in river water by single column-chromatographic separation coupled to SF-ICP-MS analysis in medium resolution mode
    Yang, Guosheng
    Zheng, Jian
    Tagami, Keiko
    Uchida, Shigeo
    Zhang, Jing
    Wang, Jinlong
    Du, Jinzhou
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2020, 220 (220-221)
  • [5] Determination of plutonium in the air by isotopic dilution ICP-MS after TNOA extraction chromatographic separation
    Jin, YR
    Gao, JF
    Bai, JF
    Zhou, GQ
    Li, L
    Xie, JC
    Wu, JF
    Wang, XH
    Zhu, FR
    ENVIRONMENTAL RADIOCHEMICAL ANALYSIS II, 2003, (291): : 263 - 272
  • [6] Determination of bromate in drinking waters using low pressure liquid chromatography/ICP-MS
    Tirez, Kristof
    Brusten, Wilfried
    Beutels, Filip
    Wevers, Mai
    Vanhaecke, Frank
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (12) : 1894 - 1902
  • [7] Sequential extraction separation for determination of technetium-99 in radwastes by ICP-MS
    J.H. Chao
    C.L. Tseng
    C.J. Lee
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 251 : 105 - 112
  • [8] Sequential extraction separation for determination of technetium-99 in radwastes by ICP-MS
    Chao, JH
    Tseng, CL
    Lee, CJ
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 251 (01) : 105 - 112
  • [9] Determination of iodine species in milk using ion chromatographic separation and ICP-MS detection
    Leiterer M.
    Truckenbrodt D.
    Franke K.
    European Food Research and Technology, 2001, 213 (2) : 150 - 153
  • [10] Determination of iodine species in milk using ion chromatographic separation and ICP-MS detection
    Leiterer, M
    Truckenbrodt, D
    Franke, K
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2001, 213 (02) : 150 - 153