Evaluation of radiation dose reduction in head CT using the half-dose method

被引:4
|
作者
Nakai, Yoshitomo [1 ,2 ]
Miyazaki, Osamu [1 ]
Kitamura, Masayuki [1 ]
Imai, Rumi [1 ]
Okamoto, Reiko [1 ]
Tsutsumi, Yoshiyuki [1 ]
Miyasaka, Mikiko [1 ]
Ogiwara, Hideki [3 ]
Miura, Hiroshi [4 ]
Yamada, Kei [2 ]
Nosaka, Shunsuke [1 ]
机构
[1] Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
[2] Kyoto Prefectural Univ Med, Dept Radiol, 465 Kawaramachi Hirokoji Kamigyo Ku, Kyoto, Japan
[3] Natl Ctr Child Hlth & Dev, Div Neurosurg, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
[4] Kyoto Daini Hosp, Dept Radiol Japanese Red Cross Soc, 355-5 Haruobicho Kamanza Dori Marutamachi Agaru,Ka, Kyoto, Japan
关键词
Computed tomography; CT dose index volume; Dose-length product; Hydrocephalus; Craniosynostosis; EXPOSURE; CHILDREN; RISK;
D O I
10.1007/s11604-023-01410-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe present study introduced the half-dose method (HDM), which halves the radiation dose for conventional head computed tomography (CT), for postoperative hydrocephalus and follow-up for craniosynostosis at a children's hospital. This study aimed to evaluate the contribution of selective head CT scanning optimization towards the overall reduction of radiation exposure.Materials and methodsWe retrospectively assessed 1227 and 1352 head CT examinations acquired before and after the introduction of the HDM, respectively, in children aged 0-15 years. The radiation exposure was evaluated using the CT dose index volume (CTDI-vol), dose-length product (DLP), rate of HDM introduction, and effect of reducing in-hospital radiation dose before and after the introduction of the HDM. For an objective evaluation of the image quality, head CT scans acquired with HDM and full-dose method (FDM) were randomly selected, and the image noise standard deviation (SD) was measured for each scan. In addition, some HDM images were randomly selected and independently reviewed by two radiologists.ResultsThe HDM was introduced in 27.9% of all head CTs. The mean CTDI-vol of all head CTs was 21.5 +/- 6.9 mGy after the introduction, a 14.9% reduction. The mean DLP was 418.4 +/- 152.9 mGy.cm after the introduction, a 17.2% reduction. Compared to the FDM images, the noise SD of the HDM ones worsened by almost 0.9; however, none of the images were difficult or impossible to evaluate.ConclusionThe HDM yielded diagnostically acceptable images. In addition, a change in protocol for only two diseases successfully reduced the patients' overall radiation exposure by approximately 15%. Introducing and optimizing the HDM for frequently performed target diseases will be useful in reducing the exposure dose for the hospital's patient population.
引用
收藏
页码:872 / 881
页数:10
相关论文
共 50 条
  • [41] RADIATION-DOSE REDUCTION IN PEDIATRIC CT
    HILL, EP
    ALABAMA JOURNAL OF MEDICAL SCIENCES, 1984, 21 (03): : 326 - 326
  • [42] RADIATION-DOSE REDUCTION IN PEDIATRIC CT
    ROBINSON, AE
    HILL, EP
    HARPEN, MD
    PEDIATRIC RADIOLOGY, 1986, 16 (01) : 53 - 54
  • [43] Radiation dose reduction in CT coronary angiography
    Shapiro B.P.
    Young P.M.
    Kantor B.
    Choe Y.H.
    McCollough C.H.
    Gerber T.C.
    Current Cardiology Reports, 2010, 12 (1) : 59 - 67
  • [44] The Latest in Radiation Dose Reduction Techniques in CT
    McCollough, C.
    Yu, L.
    Leng, S.
    Kofler, J.
    MEDICAL PHYSICS, 2010, 37 (06) : 3397 - +
  • [45] Radiation Dose Reduction at Multidetector CT Response
    Kulkarni, Naveen M.
    Uppot, Raul N.
    Eisner, Brian H.
    Sahani, Dushyant V.
    RADIOLOGY, 2013, 268 (03) : 926 - 926
  • [46] PEDIATRIC CT RADIATION-DOSE REDUCTION
    HILL, EP
    ROBINSON, AE
    HARPEN, MD
    INVESTIGATIVE RADIOLOGY, 1984, 19 (05) : S12 - S12
  • [47] RADIATION-DOSE REDUCTION IN PEDIATRIC CT
    ROBINSON, AE
    HILL, EP
    HARPEN, MD
    PEDIATRIC RADIOLOGY, 1985, 15 (01) : 69 - 69
  • [48] Radiation dose reduction in paediatric cranial CT
    C.-Y. Chan
    Yiu-chung Wong
    Luen-fai Chau
    S.-K. Yu
    Po-chung Lau
    Pediatric Radiology, 1999, 29 : 770 - 775
  • [49] Evaluation of Image Quality and Radiation Dose of Various Unenhanced Head CT Protocols
    Chen, L.
    Khan, M.
    Alapati, K.
    Hsieh, M.
    Barry, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3237 - 3237
  • [50] Half-Dose Versus Full-Dose Alteplase for Treatment of Pulmonary Embolism
    Kiser, Tyree H.
    Burnham, Ellen L.
    Clark, Brendan
    Ho, P. Michael
    Allen, Richard R.
    Moss, Marc
    Vandivier, R. William
    CRITICAL CARE MEDICINE, 2018, 46 (10) : 1617 - 1625