Evaluation of radiation dose reduction in head CT using the half-dose method
被引:4
|
作者:
论文数: 引用数:
h-index:
机构:
Nakai, Yoshitomo
[1
,2
]
Miyazaki, Osamu
论文数: 0引用数: 0
h-index: 0
机构:
Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Miyazaki, Osamu
[1
]
Kitamura, Masayuki
论文数: 0引用数: 0
h-index: 0
机构:
Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Kitamura, Masayuki
[1
]
Imai, Rumi
论文数: 0引用数: 0
h-index: 0
机构:
Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Imai, Rumi
[1
]
Okamoto, Reiko
论文数: 0引用数: 0
h-index: 0
机构:
Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Okamoto, Reiko
[1
]
Tsutsumi, Yoshiyuki
论文数: 0引用数: 0
h-index: 0
机构:
Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Tsutsumi, Yoshiyuki
[1
]
Miyasaka, Mikiko
论文数: 0引用数: 0
h-index: 0
机构:
Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Miyasaka, Mikiko
[1
]
Ogiwara, Hideki
论文数: 0引用数: 0
h-index: 0
机构:
Natl Ctr Child Hlth & Dev, Div Neurosurg, 2-10-1 Okura,Setagaya Ku, Tokyo, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Ogiwara, Hideki
[3
]
Miura, Hiroshi
论文数: 0引用数: 0
h-index: 0
机构:
Kyoto Daini Hosp, Dept Radiol Japanese Red Cross Soc, 355-5 Haruobicho Kamanza Dori Marutamachi Agaru,Ka, Kyoto, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Miura, Hiroshi
[4
]
Yamada, Kei
论文数: 0引用数: 0
h-index: 0
机构:
Kyoto Prefectural Univ Med, Dept Radiol, 465 Kawaramachi Hirokoji Kamigyo Ku, Kyoto, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Yamada, Kei
[2
]
Nosaka, Shunsuke
论文数: 0引用数: 0
h-index: 0
机构:
Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, JapanNatl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
Nosaka, Shunsuke
[1
]
机构:
[1] Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
[2] Kyoto Prefectural Univ Med, Dept Radiol, 465 Kawaramachi Hirokoji Kamigyo Ku, Kyoto, Japan
[3] Natl Ctr Child Hlth & Dev, Div Neurosurg, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
[4] Kyoto Daini Hosp, Dept Radiol Japanese Red Cross Soc, 355-5 Haruobicho Kamanza Dori Marutamachi Agaru,Ka, Kyoto, Japan
PurposeThe present study introduced the half-dose method (HDM), which halves the radiation dose for conventional head computed tomography (CT), for postoperative hydrocephalus and follow-up for craniosynostosis at a children's hospital. This study aimed to evaluate the contribution of selective head CT scanning optimization towards the overall reduction of radiation exposure.Materials and methodsWe retrospectively assessed 1227 and 1352 head CT examinations acquired before and after the introduction of the HDM, respectively, in children aged 0-15 years. The radiation exposure was evaluated using the CT dose index volume (CTDI-vol), dose-length product (DLP), rate of HDM introduction, and effect of reducing in-hospital radiation dose before and after the introduction of the HDM. For an objective evaluation of the image quality, head CT scans acquired with HDM and full-dose method (FDM) were randomly selected, and the image noise standard deviation (SD) was measured for each scan. In addition, some HDM images were randomly selected and independently reviewed by two radiologists.ResultsThe HDM was introduced in 27.9% of all head CTs. The mean CTDI-vol of all head CTs was 21.5 +/- 6.9 mGy after the introduction, a 14.9% reduction. The mean DLP was 418.4 +/- 152.9 mGy.cm after the introduction, a 17.2% reduction. Compared to the FDM images, the noise SD of the HDM ones worsened by almost 0.9; however, none of the images were difficult or impossible to evaluate.ConclusionThe HDM yielded diagnostically acceptable images. In addition, a change in protocol for only two diseases successfully reduced the patients' overall radiation exposure by approximately 15%. Introducing and optimizing the HDM for frequently performed target diseases will be useful in reducing the exposure dose for the hospital's patient population.
机构:
Seoul Natl Univ, Seoul Natl Univ Coll Med, Dept Ophthalmol, Bundang Hosp, Seongnam, South Korea
Konkuk Univ, Sch Med, Dept Ophthalmol, Seoul, South KoreaSeoul Natl Univ, Seoul Natl Univ Coll Med, Dept Ophthalmol, Bundang Hosp, Seongnam, South Korea
Kim, Hyeong Min
Kim, Hyuncheol
论文数: 0引用数: 0
h-index: 0
机构:
Sogang Univ, Dept Chem & Biomol Engn, Seoul, South KoreaSeoul Natl Univ, Seoul Natl Univ Coll Med, Dept Ophthalmol, Bundang Hosp, Seongnam, South Korea
Kim, Hyuncheol
Chung, Jae Yong
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Bundang Hosp, Dept Clin Pharmacol & Therapeut, Seongnam, South KoreaSeoul Natl Univ, Seoul Natl Univ Coll Med, Dept Ophthalmol, Bundang Hosp, Seongnam, South Korea
Chung, Jae Yong
Woo, Se Joon
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Seoul Natl Univ Coll Med, Dept Ophthalmol, Bundang Hosp, Seongnam, South KoreaSeoul Natl Univ, Seoul Natl Univ Coll Med, Dept Ophthalmol, Bundang Hosp, Seongnam, South Korea