High Performance Liquid Chromatography coupled Diode Array Detector (HPLC-DAD) method development and validation for the quantification of triclosan in toothpaste

被引:0
|
作者
Muniz-Valencia, R. [1 ]
Rodriguez-Perez, M. A. [1 ]
Barragan-Mendoza, L. [1 ]
De la Cruz-torres, L. F. [1 ]
Macias-Lopez, E. G. [1 ]
Maldonado-Michel, M. A. [1 ]
Rodriguez-Aguilar, B. A. [1 ]
Ceballos-Magana, S. G. [2 ]
机构
[1] Univ Colima, Fac Ciencias Quim, Coquimatlan Km 9, Coquimatlan 28400, Colima, Mexico
[2] Univ Colima, Fac Ciencias, C Bernal Diaz del Castillo 340, Colima 28045, Mexico
来源
REVISTA BIO CIENCIAS | 2023年 / 10卷
关键词
Emerging pollutants; endocrine disruptor; HPLC-DAD; triclosan; personal care products; EXPOSURE; TRICLOCARBAN; POPULATION; PRODUCTS; FATE;
D O I
10.15741/revbio.10.e1410
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Triclosan is used in many healthcare products as a broad-spectrum antimicrobial and disinfectant agent; however, it is currently considered an emerging pollutant. The present study aimed to develop an analytical method using liquid chromatography coupled to a Diode Array Detector for triclosan determination in toothpaste. Method development involved the optimization of separation and sample preparation. For chromatographic separation optimization, different Reverse Phase columns and elution systems were tested. After different experiments, chromatographic separation was optimized employing the following conditions: a Symmetry C18 column at 30 degrees C, 0.6 mL/min flow-rate, running time of about 3 minutes, and wavelength detection at 225 nm. To optimize toothpaste sample preparation, a response surface methodology using a Box-Behnken fractional factorial design was chosen. The sample preparation consisted of extracting 0.2 g of the sample by sonication for 7 minutes using 2 mL of methanol. According to the International Conference on Harmonization and European Commission Decision 200/657/EC guidelines, the developed method was validated. The developed analytical method was found fast, economic, linear, sensitive, precise, and robust and allowed to quantify triclosan in different healthcare products.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Development and validation of an HPLC-DAD method for the determination of moniliformin in maize
    Radic, Bojana
    Janic Hajnal, Elizabet
    Mandic, Anamarija
    Krulj, Jelena
    Stojanovic, Zorica
    Kos, Jovana
    JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2022, 46 (10)
  • [42] Determination of eumelanin and pheomelanin in melanomas using solid-phase extraction and high performance liquid chromatography-diode array detection (HPLC-DAD) analysis
    Rioux, Benjamin
    Rouanet, Jacques
    Akil, Hussein
    Besse, Sophie
    Debiton, Eric
    Bouchon, Bernadette
    Degoul, Francoise
    Quintana, Mercedes
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1113 : 60 - 68
  • [43] Validation of a method for the simultaneous quantification of chloroquine, desethylchloroquine and primaquine in plasma by HPLC-DAD
    Zuluaga-Idarraga, Lina
    Yepes-Jimenez, Natalia
    Lopez-Cordoba, Carlos
    Blair-Trujillo, Silvia
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 95 : 200 - 206
  • [44] Validation of a liquid chromatography detection method (HPLC-DAD) for the determination of aloin in Aloe vera food products
    Ulate-Molina, Ricardo
    Borbon-Alpizar, Henry
    Pablo Sibaja-Brenes, Jose
    Vega-Guzman, Hena
    Arguedas-Gonzalez, Maricruz
    UNICIENCIA, 2019, 33 (02) : 13 - 26
  • [45] A validated high performance liquid chromatography - diode array detector method for the quantification of mitomycin C in plasma, peritoneal fluid and urine
    Lemoine, Lieselotte
    Van Tiggel, Dorien
    Sugarbaker, Paul
    Van der Eycken, Johan
    Goeman, Jan
    Noben, Jean-Paul
    Penders, Joris
    Van der Speeten, Kurt
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2018, 41 (13-14) : 839 - 848
  • [46] Method development and validation for the determination of five synthetic food colorants in alcoholic beverages by reversed-phase high performance liquid chromatography coupled with diode-array detector
    Zhang, Jian
    Gao, Nianfa
    Zhang, Ying
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3080 - 3094
  • [47] Determination of Pesticides in Sunflower Seeds by High-Performance Liquid Chromatography Coupled with a Diode Array Detector
    Tuzimski, Tomasz
    Rejczak, Tomasz
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (04) : 1012 - 1020
  • [48] Quality evaluation of Houttuynia cordata Thunb. by high performance liquid chromatography with photodiode-array detection (HPLC-DAD)
    Yang, Zhan-nan
    Sun, Yi-ming
    Luo, Shi-qiong
    Chen, Jin-wu
    Yu, Zheng-wen
    Sun, Min
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 27 (02) : 223 - 231
  • [49] High Performance Liquid Chromatography-Diode Array Detector Method for the Determination of Tartrazine and Indigotine
    Yalcin, Guler
    Seyhan, Suleyman
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (16) : 8867 - 8874
  • [50] Stability indicating method for verapamil by high-performance liquid chromatography/diode array detector
    Chen, Gan-Lin
    Li, Yi-Fen
    Lee, Fang-Yu
    Chinese Pharmaceutical Journal, 2000, 52 (02): : 113 - 122