Stability indicating method for verapamil by high-performance liquid chromatography/diode array detector

被引:0
|
作者
Chen, Gan-Lin
Li, Yi-Fen
Lee, Fang-Yu
机构
来源
Chinese Pharmaceutical Journal | 2000年 / 52卷 / 02期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A stability indicating HPLC procedure for the determination of verapamil in acidic and basic media is described. The samples were analyzed before and after degradation by HPLC with C-18, CN, and phenyl columns. The peak purity of verapamil in each chromatogram was identified by a Diode Array Detector (DAD). A C-18 column using acetonitrile:triethylamine 7.3 mM pH 3.5 (33:67, v/v) as the mobile phase could be employed in chemical stability studies of verapamil. The LOQ was 2.50 μg/mL and the LOD was 0.833 μg/mL. The degradation of verapamil in 3% H2O2 and 0.1 N NaOH solutions were described. They followed second order kinetics model with rate constants of 498.5 and 339.5 M-1hr-1, respectively. The correlation coefficients were greater than 0.99.
引用
收藏
页码:113 / 122
相关论文
共 50 条
  • [1] Development and Validation of a High-Performance Liquid Chromatography Diode Array Detector Method to Measure Seven Neonicotinoids in Wheat
    Seccia, Serenella
    Albrizio, Stefania
    Morelli, Elena
    Dini, Irene
    FOODS, 2024, 13 (14)
  • [2] Determination of Pesticides in Sunflower Seeds by High-Performance Liquid Chromatography Coupled with a Diode Array Detector
    Tuzimski, Tomasz
    Rejczak, Tomasz
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (04) : 1012 - 1020
  • [3] A Simultaneous Determination of Principal Compounds in Tokishakuyakusan by High-Performance Liquid Chromatography with Diode Array Detector
    Sumino, Megumi
    Saito, Yuko
    Ikegami, Fumio
    Namiki, Takao
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (02) : 320 - 324
  • [4] Determination of glybenclamide in human plasma by high-performance liquid chromatography and diode-array detector
    Ionescu, M
    Galaon, T
    David, V
    Medvedovici, A
    REVUE ROUMAINE DE CHIMIE, 2004, 49 (3-4) : 351 - 359
  • [5] Application of a validated method in the stability study of colistin sulfate and methylparaben in a veterinary suspension formulation by high-performance liquid chromatography with a diode array detector
    Perez-Lozano, Pilar
    Garcia-Montoya, Encarna
    Orriols, Anna
    Minarro, Montse
    Tico, Josep Ramon
    Sune-Negre, Josep Maria
    JOURNAL OF AOAC INTERNATIONAL, 2007, 90 (03) : 706 - 714
  • [6] DEVELOPMENT OF A VALIDATED METHOD FOR SIMULTANEOUS QUANTIFICATION OF CLARITHROMYCIN AND LEVOFLOXACIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR
    Ijaz, Qazi Amir
    Abbas, Nasir
    Latif, Sumera
    Hussain, Amjad
    Arshad, Muhammad Sohail
    Ali, Ejaz
    Rashid, Memoona
    Sohail, Kashif
    Riaz, Sohail
    Bukhari, Nadeem Irfan
    ACTA POLONIAE PHARMACEUTICA, 2020, 77 (06): : 841 - 847
  • [7] High Performance Liquid Chromatography-Diode Array Detector Method for the Determination of Tartrazine and Indigotine
    Yalcin, Guler
    Seyhan, Suleyman
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (16) : 8867 - 8874
  • [8] Stability—Indicating assay for haloperidol syrup by high-performance liquid chromatography
    R. Driouich
    H. Trabelsi
    K. A. Bouzouita
    Chromatographia, 2001, 53 : 629 - 634
  • [9] Stability - Indicating assay for haloperidol syrup by high-performance liquid chromatography
    Driouich, R
    Trabelsi, H
    Bouzouita, KA
    CHROMATOGRAPHIA, 2001, 53 (11-12) : 629 - 634
  • [10] Nucleotide Analysis in Korean Dairy Products Using High-Performance Liquid Chromatography with Diode Array Detector
    Won, Jong-Eun
    Bang, Han-Yeol
    Kwak, Byung-Man
    Park, Jong-Su
    Kim, Gui-Ran
    Kwon, Joong-Ho
    FOOD SCIENCE OF ANIMAL RESOURCES, 2019, 39 (01) : 93 - 101