Development and Validation of a High-Performance Liquid Chromatography Diode Array Detector Method to Measure Seven Neonicotinoids in Wheat

被引:0
|
作者
Seccia, Serenella [1 ]
Albrizio, Stefania [1 ]
Morelli, Elena [1 ]
Dini, Irene [1 ]
机构
[1] Univ Naples Federico II, Dept Pharm, Via Domen Montesano 49, I-80131 Naples, Italy
关键词
pesticide residue analysis; SPE-HPLC/DAD; food security; insecticides; neonicotinoids; cereals; acetamiprid; clothianidin; dinotefuran; imidacloprid; nitenpyram; thiacloprid; thiamethoxan;
D O I
10.3390/foods13142235
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Neonicotinoids (NEOs), used as insecticides against aphids, whiteflies, lepidopterans, and beetles, have numerous detrimental impacts on human health, including chronic illnesses, cancer, infertility, and birth anomalies. Monitoring the residues in food products is necessary to guarantee public health and ecological balance. The present work validated a new method to measure seven neonicotinoid insecticides (acetamiprid ACT, clothianidin CLT, dinotefuran DNT, imidacloprid IMD, nitenpyram NTP, thiacloprid TCP, and thiamethoxan THT) in wheat. The analytical procedure was based on simple and fast wheat sample cleanup using solid-phase extraction (SPE) to remove interferents and enrich the NEOs, alongside the NEOs' separation and quantification by reverse-phase chromatography coupled with a diode array detector (DAD). The validation process was validated using the accuracy profile strategy, a straightforward decision tool based on the measure of the total error (bias plus standard deviation) of the method. Our results proved that, in the future, at least 95% of the results obtained with the proposed method would fall within the +/- 15% acceptance limits. The test's cost-effectiveness, rapidity, and simplicity suggest its use for determining the levels of acetamiprid, clothianidin, dinotefuran, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam in routine analyses of wheat.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Stability indicating method for verapamil by high-performance liquid chromatography/diode array detector
    Chen, Gan-Lin
    Li, Yi-Fen
    Lee, Fang-Yu
    Chinese Pharmaceutical Journal, 2000, 52 (02): : 113 - 122
  • [2] DEVELOPMENT OF A VALIDATED METHOD FOR SIMULTANEOUS QUANTIFICATION OF CLARITHROMYCIN AND LEVOFLOXACIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR
    Ijaz, Qazi Amir
    Abbas, Nasir
    Latif, Sumera
    Hussain, Amjad
    Arshad, Muhammad Sohail
    Ali, Ejaz
    Rashid, Memoona
    Sohail, Kashif
    Riaz, Sohail
    Bukhari, Nadeem Irfan
    ACTA POLONIAE PHARMACEUTICA, 2020, 77 (06): : 841 - 847
  • [3] Validation of a Method for Anacardic Acid Quantification in Cashew Peduncles via High-Performance Liquid Chromatography Coupled to a Diode-Array Detector
    Filho Oiram, Francisco
    Mitri, Morgana Pereira
    Zocolo, Guilherme Juliao
    Canuto, Kirley Marques
    de Brito, Edy Sousa
    FOODS, 2023, 12 (14)
  • [4] Development and validation of a rapid ultra-high performance liquid chromatography diode array detector method for Verbena officinalis L.
    Gibitz-Eisath, Nora
    Eichberger, Miriam
    Gruber, Regina
    Sturm, Sonja
    Stuppner, Hermann
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 160 : 160 - 167
  • [5] Development and validation of a rapid ultra-high performance liquid chromatography diode array detector method for Vitex agnus-castus
    Hoegner, C.
    Sturm, S.
    Seger, C.
    Stuppner, H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 927 : 181 - 190
  • [6] High Performance Liquid Chromatography coupled Diode Array Detector (HPLC-DAD) method development and validation for the quantification of triclosan in toothpaste
    Muniz-Valencia, R.
    Rodriguez-Perez, M. A.
    Barragan-Mendoza, L.
    De la Cruz-torres, L. F.
    Macias-Lopez, E. G.
    Maldonado-Michel, M. A.
    Rodriguez-Aguilar, B. A.
    Ceballos-Magana, S. G.
    REVISTA BIO CIENCIAS, 2023, 10
  • [7] Development and validation of an high-performance liquid chromatography-diode array detector method for the simultaneous determination of six phenolic compounds in abnormal savda munziq decoction
    Tian, Shuge
    Liu, Wenxian
    Liu, Feng
    Zhang, Xuejia
    Upur, Halmuart
    PHARMACOGNOSY MAGAZINE, 2015, 11 (41) : 157 - 162
  • [8] Determination of Pesticides in Sunflower Seeds by High-Performance Liquid Chromatography Coupled with a Diode Array Detector
    Tuzimski, Tomasz
    Rejczak, Tomasz
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (04) : 1012 - 1020
  • [9] A Simultaneous Determination of Principal Compounds in Tokishakuyakusan by High-Performance Liquid Chromatography with Diode Array Detector
    Sumino, Megumi
    Saito, Yuko
    Ikegami, Fumio
    Namiki, Takao
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (02) : 320 - 324
  • [10] Determination of glybenclamide in human plasma by high-performance liquid chromatography and diode-array detector
    Ionescu, M
    Galaon, T
    David, V
    Medvedovici, A
    REVUE ROUMAINE DE CHIMIE, 2004, 49 (3-4) : 351 - 359