Development and Validation of a High-Performance Liquid Chromatography Diode Array Detector Method to Measure Seven Neonicotinoids in Wheat

被引:0
|
作者
Seccia, Serenella [1 ]
Albrizio, Stefania [1 ]
Morelli, Elena [1 ]
Dini, Irene [1 ]
机构
[1] Univ Naples Federico II, Dept Pharm, Via Domen Montesano 49, I-80131 Naples, Italy
关键词
pesticide residue analysis; SPE-HPLC/DAD; food security; insecticides; neonicotinoids; cereals; acetamiprid; clothianidin; dinotefuran; imidacloprid; nitenpyram; thiacloprid; thiamethoxan;
D O I
10.3390/foods13142235
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Neonicotinoids (NEOs), used as insecticides against aphids, whiteflies, lepidopterans, and beetles, have numerous detrimental impacts on human health, including chronic illnesses, cancer, infertility, and birth anomalies. Monitoring the residues in food products is necessary to guarantee public health and ecological balance. The present work validated a new method to measure seven neonicotinoid insecticides (acetamiprid ACT, clothianidin CLT, dinotefuran DNT, imidacloprid IMD, nitenpyram NTP, thiacloprid TCP, and thiamethoxan THT) in wheat. The analytical procedure was based on simple and fast wheat sample cleanup using solid-phase extraction (SPE) to remove interferents and enrich the NEOs, alongside the NEOs' separation and quantification by reverse-phase chromatography coupled with a diode array detector (DAD). The validation process was validated using the accuracy profile strategy, a straightforward decision tool based on the measure of the total error (bias plus standard deviation) of the method. Our results proved that, in the future, at least 95% of the results obtained with the proposed method would fall within the +/- 15% acceptance limits. The test's cost-effectiveness, rapidity, and simplicity suggest its use for determining the levels of acetamiprid, clothianidin, dinotefuran, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam in routine analyses of wheat.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Identification of phenolic compounds in Myricaria bracteata leaves by high-performance liquid chromatography with a diode array detector and liquid chromatography with tandem mass spectrometry
    Alexander A. Chernonosov
    Evgeniya A. Karpova
    Elena M. Lyakh
    Revista Brasileira de Farmacognosia, 2017, 27 : 576 - 579
  • [32] Determination of squalene using high-performance liquid chromatography with diode array detection
    Lu, HT
    Jiang, Y
    Chen, F
    CHROMATOGRAPHIA, 2004, 59 (5-6) : 367 - 371
  • [33] Determination of Squalene Using High-Performance Liquid Chromatography with Diode Array Detection
    Hai-Tao Lu
    Yue Jiang
    Feng Chen
    Chromatographia, 2004, 59 : 367 - 371
  • [34] Development of a High Performance Liquid Chromatography with Diode Array Detector (HPLC-DAD) Method for Determination of Biogenic Amines in Ripened Cheeses
    Pawul-Gruba, Marzena
    Kiljanek, Tomasz
    Madejska, Anna
    Osek, Jacek
    MOLECULES, 2022, 27 (23):
  • [35] A High-Performance Liquid Chromatography with Electrochemical Detection Method Developed for the Sensitive Determination of Ascorbic Acid: Validation, Application, and Comparison with Titration, Spectrophotometric, and High-Performance Liquid Chromatography with Diode-Array Detection Methods
    Wu, Fanhua
    Xu, Fangrui
    Liu, Wen
    Chen, Sinan
    Luo, Haojie
    Cheng, Ni
    Zhao, Haoan
    Cao, Wei
    FOODS, 2023, 12 (16)
  • [36] Development and Validation of Fingerprints of Turnera diffusa Extracts Obtained by Use of High-Performance Liquid Chromatography with Diode Array Detection and Chemometric Methods
    Garza-Juarez, A.
    Waksman-De-Torres, N.
    Ramirez-Duron, R.
    Salazar Cavazos, M. L.
    ACTA CHROMATOGRAPHICA, 2009, 21 (02) : 217 - 235
  • [37] UNINTENSIFIED PHOTODIODE ARRAY FLUORESCENCE DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WEGRZYN, J
    PATONAY, G
    FORD, M
    WARNER, I
    ANALYTICAL CHEMISTRY, 1990, 62 (17) : 1754 - 1758
  • [38] Development and validation of a high-performance liquid chromatography assay for voriconazole
    Pennick, GJ
    Clark, M
    Sutton, DA
    Rinaldi, MG
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2003, 47 (07) : 2348 - 2350
  • [39] Validation of tablet dissolution method by high-performance liquid chromatography
    Guo, JH
    Harcum, WW
    Skinner, GW
    Dluzneski, PR
    Trumbull, DE
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2000, 26 (03) : 337 - 342
  • [40] Quantitation of tolmetin by high-performance liquid chromatography and method validation
    Chen, FA
    Chen, CY
    Chen, CJ
    Wu, AB
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2003, 41 (07) : 381 - 384