Design of intermittent continuous measurement of radon concentration in water

被引:1
|
作者
Hu, Tao [1 ]
Yuan, Shuai [1 ]
Mo, Yixiang [1 ]
Lin, Fen [1 ]
Fan, Zhongkai [2 ]
Liu, Shuaibin [1 ]
Xie, Ruomei [1 ]
Yi, Haibo [1 ]
Li, Huiying [1 ]
Liu, Zhipeng [1 ]
Sun, Jiale [1 ]
Wu, Jiulin [1 ]
Chen, Linquan [1 ]
Wang, Luwei [1 ]
Yuan, Hongzhi [1 ]
Tan, Yanliang [1 ,3 ]
机构
[1] Hengyang Normal Univ, Coll Phys & Elect Engn, Hengyang 421008, Hunan, Peoples R China
[2] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Hunan, Peoples R China
[3] Hengyang Normal Univ, Hengyang, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Water radon concentration; Intermittent continuous measurement; Bubbling method; RAD7; RN-222;
D O I
10.1016/j.apradiso.2023.110894
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The U.S. Environmental Protection Agency established the maximum contaminant level limit for radon concentration in drinking water as 11.1 Bq L-1. A new device based on the bubbling method with a 290 mL sample bottle was designed for intermittent continuous measurement of water radon concentration. A STM32 is used to control the switch of the water pump and the valves. The Water-Radon-Measurement software written in C# is to connect RAD7 and calculate the water radon concentration automatically.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Measurement of radon concentration in water using direct dpm method of liquid scintillation counter
    Yasuoka, Y
    Ishii, T
    Sanada, T
    Nitta, W
    Ishimori, Y
    Kataoka, Y
    Kubo, T
    Suda, H
    Tokonami, S
    Ishikawa, T
    Shinogi, M
    HIGH LEVELS OF NATURAL RADIATION AND RADON AREAS: RADIATION DOSE AND HEALTH EFFECTS, 2005, 1276 : 299 - 300
  • [32] Measurement of radon concentration levels in Pakistan: An overview
    Matiullah
    Muhammad, Wazir
    INDOOR AND BUILT ENVIRONMENT, 2017, 26 (10) : 1319 - 1334
  • [33] A SCINTILLATION COUNTER FOR MEASUREMENT OF RADON CONCENTRATION IN AIR
    COLLINSON, AJL
    HAQUE, AKM
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1963, 40 (11): : 521 - &
  • [34] INTERCOMPARISON OF DIFFERENT INSTRUMENTS FOR MEASUREMENT OF RADON CONCENTRATION
    SHIMO, M
    IIDA, T
    IKEBE, Y
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 191 : 29 - NUCL
  • [35] Measurement of radon concentration in the air by PicoRad detectors
    Chau, Nguyen Dinh
    NUKLEONIKA, 2008, 53 : S21 - S24
  • [36] CONTINUOUS MEASUREMENT OF RADON AND THORON DAUGHTERS IN THE ATMOSPHERE
    FUJINAMI, N
    ESAKA, S
    JOURNAL OF RADIATION RESEARCH, 1982, 23 (01) : 8 - 8
  • [37] Evaluation of radon concentration measurements in water using the radon degassing method
    Matsumoto, Maho
    Yasuoka, Yumi
    Takakaze, Yui
    Hosoda, Masahiro
    Tokonami, Shinji
    Iwaoka, Kazuki
    Mukai, Takahiro
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2023, 332 (01) : 167 - 172
  • [38] Evaluation of radon concentration measurements in water using the radon degassing method
    Maho Matsumoto
    Yumi Yasuoka
    Yui Takakaze
    Masahiro Hosoda
    Shinji Tokonami
    Kazuki Iwaoka
    Takahiro Mukai
    Journal of Radioanalytical and Nuclear Chemistry, 2023, 332 : 167 - 172
  • [39] SPATIAL VARIABILITY OF INDOOR RADON CONCENTRATION IN SCHOOLS: IMPLICATIONS ON RADON MEASUREMENT PROTOCOLS
    Curguz, Z.
    Venoso, G.
    Zunic, Z. S.
    Mirjanic, D.
    Ampollini, M.
    Carpentieri, C.
    Di Carlo, C.
    Caprio, M.
    Alavantic, D.
    Kolarz, P.
    Stojanovska, Z.
    Antignani, S.
    Bochicchio, F.
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (02) : 133 - 137
  • [40] Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration
    Yanliang Tan
    Detao Xiao
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 295 : 2295 - 2299