Experimental Study on a Multi-Evaporator Loop Heat Pipe with a Dual-Layer Structure Condenser

被引:1
|
作者
Lu, Depu [1 ,2 ]
Xie, Rongjian [2 ]
Wen, Jiajia [2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai 200240, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Tech Phys, Shanghai 200083, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-evaporator loop heat pipe; dual-layer condenser; heat sharing characteristic; propylene; variable heating power; adverse elevation;
D O I
10.1007/s11630-023-1829-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
A loop heat pipe (LHP) is a kind of passive heat transfer device that uses the latent heat of the working fluid and the capillary forces of the capillary wicks. It demonstrates high heat transfer efficiency, long-distance heat transfer, and high pipeline flexibility. The multi-evaporator loop heat pipe (MeLHP) is a special loop heat pipe with multiple evaporators so that heat collection and emission from multiple heat sources can be achieved. In this paper, a new type of the multi-evaporator loop heat pipe prototype with a dual-layer condenser was designed, which can ensure the uniform and symmetrical layout of pipelines. The working temperature was 20 degrees C, and propylene was used as the working fluid. The performance of the same evaporator in a single-loop LHP was considered as a reference. The experiment was conducted under two heating modes, i.e. single-evaporator heating and multi-evaporator heating, and the working stability of the prototype was verified by applying periodic heating power change and adverse elevation condition. It was observed that the prototype can be successfully started in different heating modes with a heat transfer limit of 230 W. In the test, the four loops were different in heat transfer limit due to the differences of flow resistance, and less power distribution to the loop with lowest heat transfer limit was considered to be beneficial to the prototype's performance. Meanwhile, the prototype showed good heat sharing characteristic as the maximum temperature difference is low (smaller than 2 K in single-evaporator heating mode and 0.5 K in multi-evaporator heating mode). The prototype was of good operational reliability and found to be adaptable to the adverse elevation and cyclic variation of the heating power to a certain extent.
引用
收藏
页码:1466 / 1476
页数:11
相关论文
共 50 条
  • [31] Experimental investigation of loop heat pipe with a large squared evaporator for multi-heat sources cooling
    Xiao, Biao
    Deng, Weizhong
    Ma, Zhengyuan
    He, Song
    He, Lin
    Li, Xiang
    Yuan, Fang
    Liu, Wei
    Liu, Zhichun
    RENEWABLE ENERGY, 2020, 147 : 239 - 248
  • [32] An experimental investigation of miniature loop heat pipe with flat evaporator
    Gai, Dongxing
    Liu, Wei
    Liu, Zhichun
    Yang, Jinguo
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3960 - 3963
  • [33] Experimental investigation for the loop heat pipe with a bifacial flat evaporator
    Wang, Tingting
    Zhao, Jing
    Liu, Wei
    Ma, Lei
    Liu, Zhichun
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 200
  • [34] Flat plate loop heat pipe with a novel evaporator structure
    Tsai, MC
    Yu, CS
    Kang, SW
    TWENTY-FIRST ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2005, 2005, : 187 - 190
  • [35] Experimental study on a liquid nitrogen temperature region loop heat pipe with flat evaporator
    Zhang C.
    Xie R.
    Zhang T.
    Lu D.
    Wu Y.
    Hong F.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2019, 45 (06): : 1211 - 1217
  • [36] Experimental study on a novel loop heat pipe with both flat evaporator and boiling pool
    Lu, Xiao
    Wei, Jin-Jia
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 79 : 54 - 63
  • [37] Capillary limit of a multiple-evaporator and multiple-condenser miniature loop heat pipe
    Nagano, Hosei
    Ku, Jentung
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2007, 21 (04) : 694 - 701
  • [38] Experimental study on the startup performance of dual-evaporator loop heat pipes
    Qu, Y.
    Zhou, D.
    Qiao, S.
    Zhou, K.
    Tian, Y.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 170
  • [39] EXPERIMENTAL INVESTIGATION OF A FLAT-PLATE OSCILLATING HEAT PIPE WITH MODIFIED EVAPORATOR AND CONDENSER
    Rhodes, M. J.
    Taylor, M. R.
    Monroe, J. G.
    Thompson, S. M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 8A, 2015,
  • [40] Experimental comparative study of straight and loop wickless heat pipes with rectangular evaporator and water cooled condenser
    Al-Sa'di, Samah E.
    Al-Tabbakh, Aouf A.
    Abdulrasool, Adnan A.
    HEAT AND MASS TRANSFER, 2022, 58 (04) : 695 - 705