Analysis of relative error in perturbation Monte Carlo simulations of radiative transport

被引:1
|
作者
Parsanasab, Mahsa [1 ,2 ]
Hayakawa, Carole [1 ,2 ]
Spanier, Jerome [1 ,2 ]
Shen, Yanning [3 ]
Venugopalan, Vasan [1 ,2 ]
机构
[1] Univ Calif Irvine, Dept Chem & Biomol Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Dept Elect Engn & Comp Sci, Irvine, CA USA
基金
美国国家科学基金会;
关键词
Monte Carlo simulation; perturbation methods; radiative transport; inverse problems; uncertainty estimation; multispectral analysis; optical imaging; OPTICAL-PROPERTIES; PHOTON MIGRATION; REFLECTANCE; DISCRETE;
D O I
10.1117/1.JBO.28.6.065001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: Perturbation and differential Monte Carlo (pMC/dMC) methods, used in conjunction with nonlinear optimization methods, have been successfully applied to solve inverse problems in diffuse optics. Application of pMC to systems over a large range of optical properties requires optimal "placement" of baseline conventional Monte Carlo (cMC) simulations to minimize the pMC variance. The inability to predict the growth in pMC solution uncertainty with perturbation size limits the application of pMC, especially for multispectral datasets where the variation of optical properties can be substantial. Aim: We aim to predict the variation of pMC variance with perturbation size without explicit computation of perturbed photon weights. Our proposed method can be used to determine the range of optical properties over which pMC predictions provide sufficient accuracy. This method can be used to specify the optical properties for the reference cMC simulations that pMC utilizes to provide accurate predictions over a desired optical property range. Approach: We utilize a conventional error propagation methodology to calculate changes in pMC relative error for Monte Carlo simulations. We demonstrate this methodology for spatially resolved diffuse reflectance measurements with +/- 20% scattering perturbations. We examine the performance of our method for reference simulations spanning a broad range of optical properties relevant for diffuse optical imaging of biological tissues. Our predictions are computed using the variance, covariance, and skewness of the photon weight, path length, and collision distributions generated by the reference simulation. Results: We find that our methodology performs best when used in conjunction with reference cMC simulations that utilize Russian Roulette (RR) method. Specifically, we demonstrate that for a proximal detector placed immediately adjacent to the source, we can estimate the pMC relative error within 5% of the true value for scattering perturbations in the range of [-15%; +20%]. For a distal detector placed at similar to 3 transport mean free paths relative to the source, our method provides relative error estimates within 20% for scattering perturbations in the range of [-8%; +15%]. Moreover, reference simulations performed at lower (mu(s)'/mu(a)) values showed better performance for both proximal and distal detectors. Conclusions: These findings indicate that reference simulations utilizing continuous absorption weighting (CAW) with the Russian Roulette method and executed using optical properties with a low (mu(s)'/mu(a)) ratio spanning the desired range of mu(s) values, are highly advantageous for the deployment of pMC to obtain radiative transport estimates over a wide range of optical properties. (c) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [11] Monte Carlo simulations in anomalous radiative transfer: tutorial
    Binzoni, Tiziano
    Martelli, Fabrizio
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2022, 39 (06) : 1053 - 1060
  • [12] Stochastic Perturbation Algorithms for Kinetic Monte Carlo Simulations
    Shim, Hyung Jin
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [13] ERROR ANALYSIS FOR MONTE-CARLO METHOD OF FURNACE RADIATIVE TRANSFER.
    Hu, Naiyi
    Sun, Zhaoxing
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 1985, 5 (02): : 25 - 33
  • [14] Monte Carlo versus multilevel Monte Carlo in weak error simulations of SPDE approximations
    Lang, Annika
    Petersson, Andreas
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2018, 143 : 99 - 113
  • [15] Comparative analysis of discrete and continuous absorption weighting estimators used in Monte Carlo simulations of radiative transport in turbid media
    Hayakawa, Carole K.
    Spanier, Jerome
    Venugopalan, Vasan
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2014, 31 (02) : 301 - 311
  • [16] Monte Carlo simulations of the transport of sputtered particles
    Macàk, K
    Macàk, P
    Helmersson, U
    COMPUTER PHYSICS COMMUNICATIONS, 1999, 120 (2-3) : 238 - 254
  • [17] Monte Carlo simulations of the transport of sputtered particles
    Macák, K
    Macák, P
    Helmersson, U
    ASDAM'98, SECOND INTERNATIONAL CONFERENCE ON ADVANCED SEMICONDUCTOR DEVICES AND MICROSYSTEMS, CONFERENCE PROCEEDINGS, 1998, : 63 - 66
  • [18] grmonty: A MONTE CARLO CODE FOR RELATIVISTIC RADIATIVE TRANSPORT
    Dolence, Joshua C.
    Gammie, Charles F.
    Moscibrodzka, Monika
    Leung, Po Kin
    ASTROPHYSICAL JOURNAL SUPPLEMENT SERIES, 2009, 184 (02): : 387 - 397
  • [19] On the use of Monte Carlo perturbation in neutron transport problems
    Morillon, B
    ANNALS OF NUCLEAR ENERGY, 1998, 25 (14) : 1095 - 1117
  • [20] Efficiency and stochastic error of Monte Carlo device simulations
    Jungemann, C
    Meinerzhagen, B
    INTERNATIONAL ELECTRON DEVICES MEETING 2000, TECHNICAL DIGEST, 2000, : 109 - 112