Fast ICCD-based temperature modulated fluorescence tomography

被引:0
|
作者
Nouizi, Farouk [1 ,2 ]
Kwong, Tiffany C. [1 ,3 ]
Turong, Bryan [1 ]
Nikkhah, Deniz [1 ]
Sampathkumaran, Uma [4 ]
Gulsen, Gultekin [1 ,2 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Tu & Yuen Ctr Funct Oncoimaging, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Chao Family Comprehens Canc Ctr, Irvine, CA 92697 USA
[3] Pasadena City Coll, Nat Sci Div, 1750 E Colorado Blvd, Pasadena, CA 91106 USA
[4] InnoSense LLC, 2531West 237th St,Suite 12, Torrance, CA 90505 USA
基金
美国国家卫生研究院;
关键词
DIFFUSE OPTICAL TOMOGRAPHY; TISSUE MICROENVIRONMENT; QUANTITATIVE ACCURACY; CONTRAST AGENTS; ULTRASOUND; RESOLUTION; CANCER; MICROBUBBLES; RECRUITMENT; ALGORITHM;
D O I
10.1364/AO.499281
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fluorescence tomography (FT) has become a powerful preclinical imaging modality with a great potential for several clinical applications. Although it has superior sensitivity and utilizes low-cost instrumentation, the highly scattering nature of bio-tissue makes FT in thick samples challenging, resulting in poor resolution and low quantitative accuracy. To overcome the limitations of FT, we previously introduced a novel method, termed temperature modulated fluorescence tomography (TMFT), which is based on two key elements: (1) temperature-sensitive fluorescent agents (ThermoDots) and (2) high-intensity focused ultrasound (HIFU). The fluorescence emission of ThermoDots increases up to hundredfold with only several degree temperature elevation. The exceptional and reversible response of these ThermoDots enables their modulation, which effectively allows their localization using the HIFU. Their localization is then used as functional a priori during the FT image reconstruction process to resolve their distribution with higher spatial resolution. The last version of the TMFT system was based on a cooled CCD camera utilizing a step-and-shoot mode, which necessitated long total imaging time only for a small selected region of interest (ROI). In this paper, we present the latest version of our TMFT technology, which uses a much faster continuous HIFU scanning mode based on an intensified CCD (ICCD) camera. This new, to the best of our knowledge, version can capture the whole field-of-view (FOV) of 50 x 30 mm(2) at once and reduces the total imaging time down to 30 min, while preserving the same high resolution (similar to 1.3 mm) and superior quantitative accuracy (<7% error) as the previous versions. Therefore, this new method is an important step toward utilization of TMFT for preclinical imaging. (c) 2023 Optica Publishing Group
引用
收藏
页码:7420 / 7430
页数:11
相关论文
共 50 条
  • [41] Inverse transport problem in fluorescence ultrasound modulated optical tomography with angularly averaged measurements
    Li, Wei
    Yang, Yang
    Zhong, Yimin
    [J]. INVERSE PROBLEMS, 2020, 36 (02)
  • [42] Shape based pharmacokinetic fluorescence optical tomography
    Gottam, Omprakash
    Naik, Naren
    Gambhir, Sanjay
    [J]. BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
  • [43] Fast diagnosis of volatile organic compounds with a temperature-modulated chemoresistor
    Amini, Amir
    Hosseini-Golgoo, Seyed Mohsen
    [J]. MATERIALS AND APPLICATIONS FOR SENSORS AND TRANSDUCERS, 2012, 495 : 310 - +
  • [44] Prior information in fluorescence molecular tomography based on multispectral fluorescence emission
    Axelsson, J.
    Svensson, J.
    Andersson-Engels, S.
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VII, 2007, 6434
  • [45] Temperature effect on gel swelling:: a fast transient fluorescence study
    Erdogan, M
    Pekcan, Ö
    [J]. POLYMER, 2001, 42 (11) : 4973 - 4979
  • [46] Adaptive monotone fast iterative shrinkage thresholding algorithm for fluorescence molecular tomography
    Fang, Erxi
    Wang, Jiajun
    Hu, Danfeng
    Zhang, Jingya
    Zou, Wei
    Zhou, Yue
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (05) : 587 - 595
  • [47] Fast multislice fluorescence molecular tomography using sparsity-inducing regularization
    Hejazi, Sedigheh Marjaneh
    Sarkar, Saeed
    Darezereshki, Ziba
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (02)
  • [48] Fast Continuous Iterative Methods in X-Rays Fluorescence Computed Tomography
    Miqueles, Eduardo
    De Pierro, Alvaro R.
    [J]. IC-MSQUARE 2012: INTERNATIONAL CONFERENCE ON MATHEMATICAL MODELLING IN PHYSICAL SCIENCES, 2013, 410
  • [49] Fast reconstruction of fluorescence molecular tomography via a permissible region extraction strategy
    Zhang, Jiulou
    Shi, Junwei
    Cao, Xu
    Liu, Fei
    Bai, Jing
    Luo, Jianwen
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2014, 31 (08) : 1886 - 1894
  • [50] Photoacoustic tomography and fluorescence molecular tomography: A comparative study based on indocyanine green
    Wang, Bo
    Zhao, Qing
    Barkey, Natalie M.
    Morse, David L.
    Jiang, Huabei
    [J]. MEDICAL PHYSICS, 2012, 39 (05) : 2512 - 2517