Impact of photon counting detector CT derived virtual monoenergetic images and iodine maps on the diagnosis of pleural empyema

被引:19
|
作者
Jungblut, Lisa [1 ]
Abel, Frederik [1 ]
Nakhostin, Dominik [1 ]
Mergen, Viktor [1 ]
Sartoretti, Thomas [1 ]
Euler, Andre [1 ]
Frauenfelder, Thomas [1 ]
Martini, Katharina [1 ,2 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, F-8091 Zurich, France
关键词
Computed tomography; Empyema; Pleura; Image processing; Computer -assisted image interpretation; Chest; DUAL-ENERGY CT; PARAPNEUMONIC EFFUSIONS; FEASIBILITY; CHILDREN; SYSTEM; FAT;
D O I
10.1016/j.diii.2022.09.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the impact of virtual monoenergetic image (VMI) energies and iodine maps on the diagnosis of pleural empyema with photon counting detector computed tomography (PCD-CT). Materials and methods: In this IRB-approved retrospective study, consecutive patients with non-infectious pleural effusion or histopathology-proven empyema were included. PCD-CT examinations were performed on a dual-source PCD-CT in the multi-energy (QuantumPlus) mode at 120 kV with weight-adjusted intravenous contrast-agent. VMIs from 40-70 keV obtained in 10 keV intervals and an iodine map was reconstructed for each scan. CT attenuation was measured in the aorta, the pleura and the peripleural fat (between autochthonous dorsal muscles and dorsal ribs). Contrast-to-noise (CNR) and signal-to-noise (SNR) ratios were calculated. Two blinded radiologists evaluated if empyema was present (yes/no), and rated diagnostic confidence (1 to 4; not confident to fully confident, respectively) with and without using the iodine map. Sensitivity, specificity and diagnostic confidence were estimated. Interobserver agreement was estimated using an unweighted Cohen kappa test. A one-way ANOVA was used to compare variables. Differences in sensitivity and specificity between the different levels of energy were searched using McNemar test. Results: Sixty patients (median age, 60 years; 26 women) were included. A strong negative correlation was found between image noise and VMI energies (r = -0.98; P = 0.001) and CNR increased with lower VMI energies (r = -0.98; P = 0.002). Diagnostic accuracy (96%; 95% CI: 82-100) as well as diagnostic confidence (3.4 + 0.75 [SD]) were highest at 40 keV. Diagnostic accuracy and confidence at higher VMI energies improved with the addition of iodine maps (P <= 0.001). Overall, no difference in CT attenuation of peripleural fat between patients with empyema and those with pleural effusion was found (P = 0.07). Conclusion: Low VMI energies lead to a higher diagnostic accuracy and diagnostic confidence in the diagnosis of pleural empyema. Iodine maps help in diagnosing empyema only at high VMI energies. (c) 2022 The Authors. Published by Elsevier Masson SAS on behalf of Societe francaise de radiologie. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页码:84 / 90
页数:7
相关论文
共 50 条
  • [41] Imaging of hypodense gliotic lesions in photon counting computed tomography using virtual monoenergetic images
    Schoenbeck, Denise
    Sacha, Alexander
    Niehoff, Julius Henning
    Moenninghoff, Christoph
    Borggrefe, Jan
    Kroeger, Jan Robert
    Michael, Arwed Elias
    NEURORADIOLOGY JOURNAL, 2024, 37 (03): : 336 - 341
  • [42] In vitro and in vivo optimized reconstruction for low-keV virtual monoenergetic photon-counting detector CT angiography of lower legs
    Graafen, Dirk
    Bart, Willi
    Halfmann, Moritz C.
    Mueller, Lukas
    Hobohm, Lukas
    Yang, Yang
    Neufang, Achim
    Espinola-Klein, Christine
    Pitton, Michael B.
    Kloeckner, Roman
    Emrich, Tilman
    Varga-Szemes, Akos
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [43] Optimizing Arterial Vessel Contrast in Portal Venous Phase with Virtual Monoenergetic Images from Photon-Counting Detector CT Scans of the Abdomen-First Clinical Experiences
    Dillinger, Daniel
    Overhoff, Daniel
    Ayx, Isabelle
    Kaatsch, Hanns L.
    Hagen, Achim
    Schoenberg, Stefan O.
    Waldeck, Stephan
    DIAGNOSTICS, 2024, 14 (06)
  • [44] Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (09) : 311 - 318
  • [45] Impact of Contrast Enhancement and Virtual Monoenergetic Image Energy Levels on Emphysema Quantification Experience With Photon-Counting Detector Computed Tomography
    Jungblut, Lisa
    Kronenberg, Daniel
    Mergen, Victor
    Higashigaito, Kai
    Schmidt, Bernhard
    Euler, Andre
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Martini, Katharina
    INVESTIGATIVE RADIOLOGY, 2022, 57 (06) : 359 - 365
  • [46] Photon-counting Detector CT: Initial Analysis of Virtual Noncontrast Imaging
    Sosna, Jacob
    RADIOLOGY, 2022, 305 (01) : 115 - 116
  • [47] Photon-counting detector CT-based virtual monoenergetic reconstructions: repeatability and reproducibility of radiomics features of an organic phantom and human myocardium
    Wolf, Elias V.
    Mueller, Lukas
    Schoepf, U. Joseph
    Fink, Nicola
    Griffith, Joseph P.
    Zsarnoczay, Emese
    Baruah, Dhiraj
    Suranyi, Pal
    Kabakus, Ismael M.
    Halfmann, Moritz C.
    Emrich, Tilman
    Varga-Szemes, Akos
    O'Doherty, Jim
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [48] Virtual monoenergetic images from photon-counting spectral computed tomography to assess knee osteoarthritis
    Chappard, Christine
    Abascal, Juan
    Olivier, Cecile
    Si-Mohamed, Salim
    Boussel, Loic
    Piala, Jean Baptiste
    Douek, Philippe
    Peyrin, Francoise
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2022, 6 (01)
  • [49] Virtual monoenergetic images from photon-counting spectral computed tomography to assess knee osteoarthritis
    Christine Chappard
    Juan Abascal
    Cécile Olivier
    Salim Si-Mohamed
    Loic Boussel
    Jean Baptiste Piala
    Philippe Douek
    Francoise Peyrin
    European Radiology Experimental, 6
  • [50] Photon-counting detector CT-based virtual monoenergetic reconstructions: repeatability and reproducibility of radiomics features of an organic phantom and human myocardium
    Elias V. Wolf
    Lukas Müller
    U. Joseph Schoepf
    Nicola Fink
    Joseph P. Griffith
    Emese Zsarnoczay
    Dhiraj Baruah
    Pal Suranyi
    Ismael M. Kabakus
    Moritz C. Halfmann
    Tilman Emrich
    Akos Varga-Szemes
    Jim O‘Doherty
    European Radiology Experimental, 7