Impact of photon counting detector CT derived virtual monoenergetic images and iodine maps on the diagnosis of pleural empyema

被引:19
|
作者
Jungblut, Lisa [1 ]
Abel, Frederik [1 ]
Nakhostin, Dominik [1 ]
Mergen, Viktor [1 ]
Sartoretti, Thomas [1 ]
Euler, Andre [1 ]
Frauenfelder, Thomas [1 ]
Martini, Katharina [1 ,2 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, F-8091 Zurich, France
关键词
Computed tomography; Empyema; Pleura; Image processing; Computer -assisted image interpretation; Chest; DUAL-ENERGY CT; PARAPNEUMONIC EFFUSIONS; FEASIBILITY; CHILDREN; SYSTEM; FAT;
D O I
10.1016/j.diii.2022.09.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the impact of virtual monoenergetic image (VMI) energies and iodine maps on the diagnosis of pleural empyema with photon counting detector computed tomography (PCD-CT). Materials and methods: In this IRB-approved retrospective study, consecutive patients with non-infectious pleural effusion or histopathology-proven empyema were included. PCD-CT examinations were performed on a dual-source PCD-CT in the multi-energy (QuantumPlus) mode at 120 kV with weight-adjusted intravenous contrast-agent. VMIs from 40-70 keV obtained in 10 keV intervals and an iodine map was reconstructed for each scan. CT attenuation was measured in the aorta, the pleura and the peripleural fat (between autochthonous dorsal muscles and dorsal ribs). Contrast-to-noise (CNR) and signal-to-noise (SNR) ratios were calculated. Two blinded radiologists evaluated if empyema was present (yes/no), and rated diagnostic confidence (1 to 4; not confident to fully confident, respectively) with and without using the iodine map. Sensitivity, specificity and diagnostic confidence were estimated. Interobserver agreement was estimated using an unweighted Cohen kappa test. A one-way ANOVA was used to compare variables. Differences in sensitivity and specificity between the different levels of energy were searched using McNemar test. Results: Sixty patients (median age, 60 years; 26 women) were included. A strong negative correlation was found between image noise and VMI energies (r = -0.98; P = 0.001) and CNR increased with lower VMI energies (r = -0.98; P = 0.002). Diagnostic accuracy (96%; 95% CI: 82-100) as well as diagnostic confidence (3.4 + 0.75 [SD]) were highest at 40 keV. Diagnostic accuracy and confidence at higher VMI energies improved with the addition of iodine maps (P <= 0.001). Overall, no difference in CT attenuation of peripleural fat between patients with empyema and those with pleural effusion was found (P = 0.07). Conclusion: Low VMI energies lead to a higher diagnostic accuracy and diagnostic confidence in the diagnosis of pleural empyema. Iodine maps help in diagnosing empyema only at high VMI energies. (c) 2022 The Authors. Published by Elsevier Masson SAS on behalf of Societe francaise de radiologie. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页码:84 / 90
页数:7
相关论文
共 50 条
  • [21] Performance improvements of virtual monoenergetic images in photon-counting detector CT compared with dual source dual-energy CT: Fourier-based assessment
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Yoshida, Ryoichi
    Katayama, Takuto
    Arimoto, Makoto
    Kataoka, Jun
    Nagata, Hiroji
    Kobayashi, Satoshi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, : 143 - 153
  • [22] Optimized Virtual Monoenergetic Image Generation Via Adversarial Learning in Multi-Energy and Photon Counting Detector CT
    Chang, S.
    Koons, E.
    Gong, H.
    McCollough, C. H.
    Leng, S.
    MEDICAL PHYSICS, 2024, 51 (09) : 6648 - 6648
  • [23] Optimal Virtual Monoenergetic Photon Energy (keV) for Photon-Counting-Detector Computed Tomography Angiography
    Dunning, Chelsea A. S.
    Rajendran, Kishore
    Inoue, Akitoshi
    Rajiah, Prabhakar
    Weber, Nikkole
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (04) : 569 - 575
  • [24] Optimisation of virtual monoenergetic reconstructions for the diagnosis of pulmonary embolism using photon-counting detector computed tomography angiography
    Chamberlin, Jordan H.
    Toth, Adrienn
    Hinen, Shaun
    O'Doherty, Jim
    Baruah, Dhiraj
    Maisuria, Dhruw
    Mcguire, Aaron
    Knight, Heather
    Schoepf, U. Joseph
    Munden, Reginald F.
    Kabakus, Ismail M.
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e63 - e69
  • [25] Editorial Comment: Stability of Virtual Monoenergetic Images From Photon-Counting Detector CT May Allow Broader Quantitative Applications in Research and Clinical Practice
    Obmann, Markus M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (05)
  • [26] Imaging of intracranial hemorrhage in photon counting computed tomography using virtual monoenergetic images
    Denise Schoenbeck
    Alexander Sacha
    Julius Henning Niehoff
    Christoph Moenninghoff
    Jan Borggrefe
    Sebastian Horstmeier
    Alexey Surov
    Iram Shahzadi
    Ulrich Knappe
    Jan Robert Kroeger
    Arwed Elias Michael
    Neuroradiology, 2024, 66 : 729 - 736
  • [27] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [28] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Yannik C. Layer
    Narine Mesropyan
    Patrick A. Kupczyk
    Julian A. Luetkens
    Alexander Isaak
    Tatjana Dell
    Ulrike I. Attenberger
    Daniel Kuetting
    Scientific Reports, 13
  • [29] Imaging of intracranial hemorrhage in photon counting computed tomography using virtual monoenergetic images
    Schoenbeck, Denise
    Sacha, Alexander
    Niehoff, Julius Henning
    Moenninghoff, Christoph
    Borggrefe, Jan
    Horstmeier, Sebastian
    Surov, Alexey
    Shahzadi, Iram
    Knappe, Ulrich
    Kroeger, Jan Robert
    Michael, Arwed Elias
    NEURORADIOLOGY, 2024, 66 (05) : 729 - 736
  • [30] Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
    Booij, Ronald
    van der Werf, Niels R.
    Dijkshoorn, Marcel L.
    van der Lugt, Aad
    van Straten, Marcel
    DIAGNOSTICS, 2022, 12 (06)