Markerless head motion tracking and event-by-event correction in brain PET

被引:6
|
作者
Zeng, Tianyi [1 ]
Lu, Yihuan [1 ,2 ]
Jiang, Weize [2 ]
Zheng, Jiaxu [2 ]
Zhang, Jiazhen [1 ]
Gravel, Paul [1 ]
Wan, Qianqian [2 ]
Fontaine, Kathryn [1 ]
Mulnix, Tim [1 ]
Jiang, Yulin [2 ]
Yang, Zhaohui [2 ]
Revilla, Enette Mae [1 ]
Naganawa, Mika [1 ]
Toyonaga, Takuya [1 ]
Henry, Shannan [1 ]
Zhang, Xinyue [2 ]
Cao, Tuoyu [2 ]
Hu, Lingzhi [2 ]
Carson, Richard E. [1 ]
机构
[1] Yale Univ, Dept Radiol & Biomed Imaging, New Haven, CT 06520 USA
[2] United Imaging Healthcare, Houston, TX USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 24期
关键词
markerless motion tracking system; PET; head motion; event-by-event correction; registration quality metric; 1ST-IN-HUMAN; REGISTRATION; MCT;
D O I
10.1088/1361-6560/ad0e37
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Head motion correction (MC) is an essential process in brain positron emission tomography (PET) imaging. We have used the Polaris Vicra, an optical hardware-based motion tracking (HMT) device, for PET head MC. However, this requires attachment of a marker to the subject's head. Markerless HMT (MLMT) methods are more convenient for clinical translation than HMT with external markers. In this study, we validated the United Imaging Healthcare motion tracking (UMT) MLMT system using phantom and human point source studies, and tested its effectiveness on eight 18F-FPEB and four 11C-LSN3172176 human studies, with frame-based region of interest (ROI) analysis. We also proposed an evaluation metric, registration quality (RQ), and compared it to a data-driven evaluation method, motion-corrected centroid-of-distribution (MCCOD). Approach. UMT utilized a stereovision camera with infrared structured light to capture the subject's real-time 3D facial surface. Each point cloud, acquired at up to 30 Hz, was registered to the reference cloud using a rigid-body iterative closest point registration algorithm. Main results. In the phantom point source study, UMT exhibited superior reconstruction results than the Vicra with higher spatial resolution (0.35 +/- 0.27 mm) and smaller residual displacements (0.12 +/- 0.10 mm). In the human point source study, UMT achieved comparable performance as Vicra on spatial resolution with lower noise. Moreover, UMT achieved comparable ROI values as Vicra for all the human studies, with negligible mean standard uptake value differences, while no MC results showed significant negative bias. The RQ evaluation metric demonstrated the effectiveness of UMT and yielded comparable results to MCCOD. Significance. We performed an initial validation of a commercial MLMT system against the Vicra. Generally, UMT achieved comparable motion-tracking results in all studies and the effectiveness of UMT-based MC was demonstrated.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Neural Implicit Event Generator for Motion Tracking
    Masuda, Mana
    Sekikawa, Yusuke
    Fujii, Ryo
    Saito, Hideo
    2022 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA 2022), 2022, : 2200 - 2206
  • [42] Motion Segmentation and Tracking for Integrating Event Cameras
    Freeman, Andrew C.
    Burgess, Chris
    Mayer-Patel, Ketan
    MMSYS '21: PROCEEDINGS OF THE 2021 MULTIMEDIA SYSTEMS CONFERENCE, 2021, : 1 - 11
  • [43] Fast motion tracking of radioactive markers for motion correction of awake and unrestrained rat brain PET
    Miranda, A.
    Staelens, S.
    Stroobants, S.
    Verhaeghe, J.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [44] Rigid Motion Correction for Brain PET/MR Imaging Using Optical Tracking
    Spangler-Bickell, Matthew G.
    Khalighi, Mohammad Mehdi
    Hoo, Charlotte
    DiGiacomo, Phillip Scott
    Maclaren, Julian
    Aksoy, Murat
    Rettmann, Dan
    Bammer, Roland
    Zaharchuk, Greg
    Zeineh, Michael
    Jansen, Floris
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (04) : 498 - 503
  • [45] Head and Neck Motion Correction in PET Imaging Using New Particle Tracking Techniques
    Osborne, Dustin
    Lee, Sang Hyeb
    Hu, Dongming
    Acuff, Shelley
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [46] Precision spectroscopy of fast, hot, exotic isotopes using machine-learning-assisted event-by-event Doppler correction
    Udrescu, S. M.
    Torres, D. A.
    Ruiz, R. F. Garcia
    PHYSICAL REVIEW RESEARCH, 2024, 6 (01):
  • [47] An Event-Driven Motion Correction Method for Neurological PET Studies of Awake Laboratory Animals
    Victor W Zhou
    Andre Z Kyme
    Steven R Meikle
    Roger Fulton
    Molecular Imaging and Biology, 2008, 10 : 315 - 324
  • [48] Correction of motion in PET using event-based rebinning method: Pitfall and solution.
    Qi, J
    Huesman, RH
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 146P - 146P
  • [49] An event-driven motion correction method for neurological PET studies of awake laboratory animals
    Zhou, Victor W.
    Kyme, Andre Z.
    Meikle, Steven R.
    Fulton, Roger
    MOLECULAR IMAGING AND BIOLOGY, 2008, 10 (06) : 315 - 324
  • [50] Motion correction in PET brain studies
    Herzog, H
    Tellman, L
    Fulton, R
    Pietrzyk, U
    FOURTH INTERNATIONAL WORKSHOP ON MULTIDIMENSIONAL SYSTEMS - NDS 2005, 2005, : 178 - 181