Multimodality 3D image fusion with live fluoroscopy reduces radiation dose during catheterization of congenital heart defects

被引:0
|
作者
Buytaert, Dimitri [1 ]
Vandekerckhove, Kristof [2 ]
Panzer, Joseph [2 ]
Campens, Laurence [3 ]
Bacher, Klaus [1 ]
De Wolf, Daniel [2 ,4 ]
机构
[1] Univ Ghent, Dept Human Struct & Repair, Ghent, Belgium
[2] Ghent Univ Hosp, Dept Paediat Cardiol, Ghent, Belgium
[3] Ghent Univ Hosp, Dept Cardiol, Ghent, Belgium
[4] Brussels Univ Hosp, Dept Paediat Cardiol, Jette, Belgium
来源
关键词
congenital heart disease; cardiac catheterization; multimodality image fusion; radiation exposure; contrast media; 3D guidance; radiation dose structured report; 3-DIMENSIONAL ROTATIONAL ANGIOGRAPHY; CANCER-RISK ESTIMATION; CARDIAC-CATHETERIZATION; MAGNETIC-RESONANCE; EXPOSURE; GUIDANCE; CHILDREN; DISEASE; EXPERIENCE;
D O I
10.3389/fcvm.2023.1292039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionImaging fusion technology is promising as it is radiation and contrast sparing. Herein, we compare conventional biplane angiography to multimodality image fusion with live fluoroscopy using two-dimensional (2D)-three-dimensional (3D) registration (MMIF2D-3D) and assess MMIF2D-3D impact on radiation exposure and contrast volume during cardiac catheterization of patients with congenital heart disease (CHD).MethodsWe matched institutional MMIF2D-3D procedures and controls according to patient characteristics (body mass index, age, and gender) and the seven procedure-type subgroups. Then, we matched the number of tests and controls per subgroup using chronological ordering or propensity score matching. Subsequently, we combined the matched subgroups into larger subgroups of similar procedure type, keeping subgroups with at least 10 test and 10 control cases. Air kerma (AK) and dose area product (DAP) were normalized by body weight (BW), product of body weight and fluoroscopy time (BW x FT), or product of body weight and number of frames (BW x FR), and stratified by acquisition plane and irradiation event type (fluoroscopy or acquisition). Three senior interventionists evaluated the relevance of MMIF2D-3D (5-point Likert scale).ResultsThe Overall group consisted of 54 MMIF2D-3D cases. The combined and matched subgroups were pulmonary artery stenting (StentPUL), aorta angioplasty (PlastyAO), pulmonary artery angioplasty (PlastyPUL), or a combination of the latter two (Plasty). The FT of the lateral plane reduced significantly by 69.6% for the Overall MMIF2D-3D population. AKBW and DAPBW decreased, respectively, by 43.9% and 39.3% (Overall group), 49.3% and 54.9% (PlastyAO), and 36.7% and 44.4% for the Plasty subgroup. All the aforementioned reductions were statistically significant except for DAPBW in the Overall and Plasty (sub)groups. The decrease of AKBW and DAPBW in the StentPUL and PlastyPUL subgroups was not statistically significant. The decrease in the median values of the weight-normalized contrast volume (CMCBW) in all five subgroups was not significant. Cardiologists considered MMIF2D-3D very useful with a median score of 4.ConclusionIn our institution, MMIF2D-3D overall enabled significant AKBW reduction during the catheterization of CHD patients and was mainly driven by reduced FT in the lateral plane. We observed significant AKBW reduction in the Plasty and PlastyAO subgroups and DAPBW reduction in the PlastyAO subgroup. However, the decrease in CMCBW was not significant.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Utility of an image fusion system for 3D preoperative planning and fluoroscopy in the osteosynthesis of distal radius fractures
    Yuichi Yoshii
    Yasukazu Totoki
    Satoshi Sashida
    Shinsuke Sakai
    Tomoo Ishii
    Journal of Orthopaedic Surgery and Research, 14
  • [22] Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
    Vernikouskaya, Ina
    Rottbauer, Wolfgang
    Seeger, Julia
    Gonska, Birgid
    Woehrle, Jochen
    Rasche, Volker
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (136):
  • [23] Radiation Safety in Children With Congenital and Acquired Heart Disease A Scientific Position Statement on Multimodality Dose Optimization From the Image Gently Alliance
    Hill, Kevin D.
    Frush, Donald P.
    Han, B. Kelly
    Abbott, Brian G.
    Armstrong, Aimee K.
    DeKemp, Robert A.
    Glatz, Andrew C.
    Greenberg, S. Bruce
    Herbert, Alexander Sheldon
    Justino, Henri
    Mah, Douglas
    Mahesh, Mahadevappa
    Rigsby, Cynthia K.
    Slesnick, Timothy C.
    Strauss, Keith J.
    Trattner, Sigal
    Viswanathan, Mohan N.
    Einstein, Andrew J.
    JACC-CARDIOVASCULAR IMAGING, 2017, 10 (07) : 797 - 818
  • [24] Solving controversial findings in a heart transplant recipient with 3D image fusion
    Von Spiczak, Jochen
    Model, Hanna
    Manka, Robert
    Alkadhi, Hatem
    IMAGING, 2020, 12 (01): : 13 - 14
  • [25] New developments in the diagnosis of coronary heart disease - 3D fusion image
    Schindler, TH
    Magosaki, N
    Jeserich, M
    Krause, T
    Fischer, R
    Moser, E
    Nitzsche, E
    Just, H
    Solzbach, U
    ZEITSCHRIFT FUR KARDIOLOGIE, 2000, 89 (04): : 338 - 348
  • [26] Differences in Accuracy and Radiation Dose in Placement of Iliosacral Screws: Comparison between 3D and 2D Fluoroscopy
    Kulakowski, Michal
    Reichert, Pawel
    Elster, Karol
    Witkowski, Jaroslaw
    Sleczka, Pawel
    Morasiewicz, Piotr
    Oleksy, Lukasz
    Krolikowska, Aleksandra
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (06)
  • [27] Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizations
    Schultz, FW
    Geleijns, J
    Spoelstra, FM
    Zoetelief, J
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (909): : 638 - 647
  • [28] Fusion of 3D echo and cardiac magnetic resonance volumes during live scanning
    Kiss, Gabriel
    Ford, Steven
    Claus, Piet
    D'hooge, Jan
    Torp, Hans
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 824 - 827
  • [29] Determining 3D Kinematics of the Hip Using Video Fluoroscopy: Guidelines for Balancing Radiation Dose and Registration Accuracy
    D'Isidoro, Fabio
    Eschle, Patrik
    Zumbrunn, Thomas
    Sommer, Christian
    Scheidegger, Stephan
    Ferguson, Stephen J.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (10): : 3213 - 3218
  • [30] Using 3D Physical Modeling to Plan Surgical Corrections of Complex Congenital Heart Defects
    Vodiskar, Janez
    Kuetting, Maximilian
    Steinseifer, Ulrich
    Vazquez-Jimenez, Jaime Francisco
    Sonntag, Simon J.
    THORACIC AND CARDIOVASCULAR SURGEON, 2017, 65 (01): : 31 - 35